manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Gateway
  6. •
  7. Server
  8. •
  9. Gateway GR585 F1 User manual

Gateway GR585 F1 User manual

Other Gateway Server manuals

Gateway GR380 F1 User manual

Gateway

Gateway GR380 F1 User manual

Gateway ALR 8300 Assembly Instructions

Gateway

Gateway ALR 8300 Assembly Instructions

Gateway 7450R User manual

Gateway

Gateway 7450R User manual

Gateway ALR 7200 Assembly Instructions

Gateway

Gateway ALR 7200 Assembly Instructions

Gateway ALR 9000 Assembly Instructions

Gateway

Gateway ALR 9000 Assembly Instructions

Gateway GT150 F1 User manual

Gateway

Gateway GT150 F1 User manual

Gateway ALR 7300 Assembly Instructions

Gateway

Gateway ALR 7300 Assembly Instructions

Gateway E-9520T User manual

Gateway

Gateway E-9520T User manual

Gateway 8300 User manual

Gateway

Gateway 8300 User manual

Gateway 9715 User manual

Gateway

Gateway 9715 User manual

Gateway 8400 User guide

Gateway

Gateway 8400 User guide

Gateway 8400 User manual

Gateway

Gateway 8400 User manual

Gateway 6400 User guide

Gateway

Gateway 6400 User guide

Gateway 9315 User manual

Gateway

Gateway 9315 User manual

Gateway E-9425R User manual

Gateway

Gateway E-9425R User manual

Gateway 7250R User manual

Gateway

Gateway 7250R User manual

Gateway E-9722R User manual

Gateway

Gateway E-9722R User manual

Gateway E-9220T User manual

Gateway

Gateway E-9220T User manual

Gateway 910 Series User guide

Gateway

Gateway 910 Series User guide

Gateway 955 User manual

Gateway

Gateway 955 User manual

Gateway 9510 User manual

Gateway

Gateway 9510 User manual

Gateway 9210 User manual

Gateway

Gateway 9210 User manual

Gateway 7250R User guide

Gateway

Gateway 7250R User guide

Gateway ALR 8200R User manual

Gateway

Gateway ALR 8200R User manual

Popular Server manuals by other brands

HP Tc2120 - Server - 256 MB RAM installation guide

HP

HP Tc2120 - Server - 256 MB RAM installation guide

Lenovo ThinkServer RD230 manual

Lenovo

Lenovo ThinkServer RD230 manual

Avocent CPS810 Installer/user guide

Avocent

Avocent CPS810 Installer/user guide

Dell PowerEdge R6615 Installation and service manual

Dell

Dell PowerEdge R6615 Installation and service manual

FreeWave HT2+ installation guide

FreeWave

FreeWave HT2+ installation guide

GIGA-BYTE TECHNOLOGY G492-Z50 user manual

GIGA-BYTE TECHNOLOGY

GIGA-BYTE TECHNOLOGY G492-Z50 user manual

Lanner HTCA-E400 user manual

Lanner

Lanner HTCA-E400 user manual

Bull NovaScale T840 E2 user guide

Bull

Bull NovaScale T840 E2 user guide

Asus RS740-E70RS24-EG Configuration guide

Asus

Asus RS740-E70RS24-EG Configuration guide

Meinberg LANTIME M300/TCR manual 

Meinberg

Meinberg LANTIME M300/TCR manual 

HP ProLiant SL335s G7 Maintenance and service guide

HP

HP ProLiant SL335s G7 Maintenance and service guide

ZyXEL Communications VANTAGE RADIUS 50 user guide

ZyXEL Communications

ZyXEL Communications VANTAGE RADIUS 50 user guide

Lantronix xDirect-IAP quick start guide

Lantronix

Lantronix xDirect-IAP quick start guide

Fujitsu PRIMEQUEST 2400E3 General description

Fujitsu

Fujitsu PRIMEQUEST 2400E3 General description

IBM 9040-MR9 manual

IBM

IBM 9040-MR9 manual

IBM 306m - eServer xSeries - 8849 user guide

IBM

IBM 306m - eServer xSeries - 8849 user guide

green hippo Hippotizer Nevis+ quick start guide

green hippo

green hippo Hippotizer Nevis+ quick start guide

IBM 8203-E4A Brochure & specs

IBM

IBM 8203-E4A Brochure & specs

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
GR585 F1 specifications
Product overview
The Gateway GR585 F1 is a four-socket 2U server for space-conscious users who demand the highest
performance and utmost expansion capability. Delivering the latest technology, this server was designed
for cost-effective growth and includes a comprehensive list of management features.
Internal view
1 2 x 1400 W 80 PLUS
®
gold-level efficient easy-swap power supplies (1+1 redundant, hot-pluggable)
2 4 x AMD Opteron
™
6100 series processors
3 32 x DDR3 ECC registered / unbuffered DIMMs
4 N+1 redundant cooling fans
5 4 x PCIe expansion slots
6 6 x 3.5” hot-swappable hard drive bays
2
GR585 F1 specifications
Front View
Rear View
*Note: Rear expansion may vary by model
Front I/O
1 2 x USB 2.0 ports
2 Serial port
2 Network, hard drive, power, and system status indicators
Rear I/O
1 PS2 mouse and keyboard ports
2 2 x USB ports
3 2 x Gigabit LAN port (RJ-45)
4 Video port
5 Serial port
6 System ID LED
7 Management port (RJ-45)
What's New
•New AMD Opteron™6100 series processors
AMD Opteron 6176, 6140, 6166HE, and 6132HE
•Hot-pluggable/redundant power supply with 80 PLUS®gold-level efficiency
•Smart Server Manager v1.1 with improved management functionality
Product Specifications
Processors and Chipset
•Up to four AMD Opteron 6100 series processors
•Chipset: AMD SR5690 and SR5670/SP5100
3
GR585 F1 specifications
Memory
•Memory capacity:
•Registered DIMM: 2, 4, 8, 16 GB
•Unbuffered DIMM: 2, 4 GB
•Up to 512 GB registered DIMMs when fully populated with 2 DIMMs per channel in 32 slots
•Up to 128 GB unbuffered DIMMs when fully populated with 2 DIMMs per channel in 32 slots
Network Controllers
•Integrated Intel® 82576EB Gigabit Ethernet Controller with dual ports
Storage
•Hard disk form factor: 3.5”
•Type: SAS/ SATA with hot-plug capability
•3.5” Maximum capacity:
•Up to 12 TB SATA (2 TB 3.5" x 6 HDDs)
•Up to 3.6 TB SAS (600 GB 3.5” x 6 HDDs)
Storage Controllers
•Integrated AMD®SP5100 Chipset Serial ATA host controller with RAID 0, 1, 10 support
•Optional PCIe 4-/8-port SAS RAID card
Expansion slots
•Two low profile PCI-E 2.0 x16 slots
•One low profile PCI-E 2.0 x8 slot
•One Gateway Flex I/O x8 or PCI-E 2.0 x8 slot
Management
•Gateway Smart Server Manager
•System ID LED buttons, System Health LED
•Gateway Smart Console for server management and KVM over IP remote management
Deployment/Serviceability
•Gateway Smart Setup
•BIOS Update Tool
•IPMI Firmware Update Tool
Operating Systems
•Windows Server®2008
•Windows Server®2008 R2
•Windows Server®2003
•Red Hat®Enterprise Linux 5
•SuSE®Linux Enterprise Server 11 SP1
•VMware ESXi™4 update 1
•VMware ESX™4 update 1
Input/output interface
Front
•2 x USB 2.0 ports
4
GR585 F1 specifications
•
Serial port
•Network, hard drive and power, and system status indicators
Rear
•PS2 mouse and keyboard ports
•2 x USB ports
•2 x Gigabit LAN port (RJ-45)
•Video port
•Serial port
•System ID LED
•Management port (RJ-45)
Chassis/Form Factor
•2U rack optimized
Power Supply
•2 x 1400 W 80 PLUS® gold-level efficient, easy-swap power supply (1+1 redundant, hot-pluggable)
Regulatory Compliant Standards
EMC
•FCC (Class A)
•CE (Class A)
•BSMI (Class A)
Safety
•UL/cUL
•CB
Nemko/GS
Environmental Specifications
Dimensions 437 (W) x 709 (D) x 89 (H) mm (17.2 × 27.9 × 3.5 inches)
Weight Maximum 25.9 kg (57 lbs)
Minimum (includes a single HDD, CPU and
RAM, and PSU)
18.6 kg (41 lbs)
System inlet
temperature
Operating 10°- 35°C (50°- 95°F)
Non-operating -40°- 70°C (-40°- 158°F)
Relative
humidity
Operating 8 - 90 %
Non-operating 5 - 95 %
Acoustics Idle
LWAd 6.7 BA
LpAm 54.1 dBA
Operating
LWAd 7.7 BA
LpAm 67.7 dBA
5
GR585 F1 specifications
Power Rated Steady –state power 1400 W
Maximum Peak Power 1400 W
BTU rating 4095 BTU/hr at 100 - 140V AC
4778 BTU/hr at 180-240V AC
6
GR585 F1 specifications
Technical specifications
PCIe®specifications
The primary I/O bus for the main board is PCIe Gen2. The following table lists the characteristics of the PCI-
E bus segments. Details about each bus segment follow the table.
NOTE: The signaling bit rate of PCI Express is 2.5Gbit/s one direction per lane for Gen 1 and 5.0Gbit/s one
direction per lane for Gen 2.
Expansion
slot
Number Type Bus
width1
Voltage Connector Location Length
PCIe x16 2 PCIe
Gen2
x16 3.3V x16 Onboard Low-profile
PCIe x81 Up to 2 PCIe
Gen2
x8 3.3V x8 Onboard Low-profile
Flex I/O1 1 PCIe
Gen2
x8 3.3V x8 Onboard Low-profile
NOTE:
1. If the Flex I/O slot is used, the second PCIe x8 cannot be used.
2. Indicates the number of physical electrical lanes running to a PCIe® connector.
2. Default bus assignment (in decimal). Inserting cards with PCI™ bridges may alter the actual bus
assignment number.
3. Slots are enumerated differently based on the operating system. Microsoft® operating systems enumerate
Device ID by bus starting from the lowest bus to the highest.
Onboard storage specifications
Item Description
Controller AMD®SP5100 SATA controller
Simultaneous drive transfer channels 6 onboard SATA ports
Max throughput per channel 3 Gb/s
Data transfer method •Non-RAID mode
•RAID mode (Adaptec RAID driver)
Drive type supported Serial ATA
RAID levels support •RAID 0, 1, 10 (Adaptec software RAID)
RAID function support Supports multiple logical volumes
Setup through ROM based Array Configuration Utility
Installation scripting support
NOTE: This controller does not support LED functions
RAID OS support
•
Windows Server 2008
•Windows Server 2008 R2
•Windows Server 2003
•Red Hat Enterprise Linux 5.4
7
GR585 F1 specifications
•
SuSE Linux Enterprise Server 11
Additional features •NCQ (Native Command Queuing)
•AHCI (Advanced Host Controller Interface)
Onboard LAN specifications
Item Description
Controller 1 x Intel®82576EB Gigabit Ethernet Controller
(2 ports total)
Network interface 10Base-T / 100Base-TX / 1000Base-T
Compatibility standards •IEEE 802.3 Ethernet interface for 10BASE-T
•IEEE 802.3ab Ethernet interface for 1000BASE-T,
•IEEE 802.3u Ethernet interface for 100BASE-TX
Manageability •NC-SI, SMBus
•PXE, iSCSI boot
Virtualization acceleration Intel
®
I/O Acceleration Technology
Virtual Machine Device Queues (VMDq)
PCI-SIG SR-IOV implementation
Connector RJ-45
Supported cable type CAT 5e wire
Memory specifications and population
Item Description
Supported memory types •Registered DDR3 1066 / 1333 MHz
•Unbuffered DDR3 1066 / 1333 MHz
NOTE: Gateway does not qualify mixed memory configurations of
memory type, capacity or make.
Population Gateway’s validated memory populations are listed below.
NOTE: Support for 8 / 16 GB DIMMs may vary by regional
availability.
Dual processor configuration guide
DIMM# CPU 1 CPU 2
4B 4A 3B 3A 2B 2A 1B 1A 4B 4A 3B 3A 2B 2A 1B 1A
4 x x x x
8 x x x x x x x x
16 x x x x x x x x x x x x x x x x
8
GR585 F1 specifications
Quad processor configuration guide
CPU1 CPU2 CPU3 CPU4
# 4
B
4
A
3
B
3
A
2
B
2
A
1
B
1
A
4
B
4
A
3
B
3
A
2
B
2
A
1
B
1
A
4
B
4
A
3
B
3
A
2
B
2
A
1
B
1
A
4
B
4
A
3
B
3
A
2
B
2
A
1
B
1
A
8 x x x x x x x x
16 x x x x x x x x x x x x x x x x
32 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
On-Line Spare
On-line spare is a RAS mechanism that allows the system to reserve one rank of one logical DIMM to be
used as a spare rank. The spare rank must be greater than or equal to the size of all other ranks in the
system. The system can switch to the spare rank when system software determines that one of the ranks in
the system is no longer functioning properly and needs to be replaced.
Memory Identification
Generally, there are some memory information printed on the label of DIMM, but different vendor may have
different format. For example:
4GB 2Rx4 PC3-10600R xx xx xxx
1. Density
1GB, 2GB, 4GB, 8GB, 16GB
2. Rank
1R = Single Rank
2R = Dual Rank
4R = Quad Rank
Note: if any quad rank DIMM is used, maximum only 2 DIMM per channel can be supported
3. Bit Organization
This platform supports x4 and x8
Note: It’s not recommend to mix DIMM with different bit organization in one system
4. Speed
PC3 – 6400 => DDR3- 800
PC3 – 8500 => DDR3- 1066
PC3 – 10600 => DDR3- 1333
9
GR585 F1 specifications
Power specifications
1400W Power Supply
Operational Input
Voltage Range
(Vrms)
1200W: 100-140 VAC
1400W: 180 – 240 VAC
Frequency
Range (Nominal)
(Hz)
60/50
Nominal Input
Voltage (Vrms)
100 120 208 200 220 230 240
Max. Rated
Output Wattage 1237.3 1237.4 1403.4 1403.4 1403.2 1403.0 1403.7
Nominal Input
Current (A rms) 14.21 11.95 7.92 7.62 7.13 6.83 6.55
Max. Rated Input
Wattage Rating
(Watts)
1416.74
1428.26 1577.66 1578.62 1560.76 1559.90 1561.00
Max. Rated VA
(Volt-Amp) 1421.0 1434.0 1584.0 1585.0 1568.6 1570.9 1572.0
Efficiency (%) at
Max. Rated
Output Wattage
87.33% 86.64% 88.95% 88.90% 89.91% 89.94% 89.92%
Power Factor 0.997 0.996 0.996 0.996 0.995 0.993 0.993
Leakage Current
(mA) 1.1 1.2 1.1 1.1 1.2 1.2 1.2
Max. Inrush
Current (A peak) 16.74 15.98 16.05 16.11 15.70 15.89 16.20
Max. Inrush
Current Duration
(mS)
4.61 4.60 4.63 4.63 4.65 4.72 4.75
Max. British
Thermal Unit
Rating (BTU/hr)
4222.90
4223.24 4789.80 4789.80 4789.12 4788.439 4790.82
10
GR585 F1 specifications
Gateway server software utilities
Smart Setup 2.0
Easy deployment via the latest version of Gateway’s Smart Setup. Smart Setup is
available both in box as a driver packed installation DVD or a downloadable file to be
put into a USB 2.0 device, and eases the deployment of Gateway servers for any
certified OS. Through its unique interface, users may select to have all the correct
drivers be pre-deployed for the OS of their choosing, as well as setup hardware RAID
devices, BMC settings (where available), and even clone the pre-settings to a
bootable USB device to ease mass server deployments.
Smart Console
Web-based management utility to simplify system management with embedded
iBMC, system monitoring and alerting, event handling, remote power control and
KVM-over-IP. Smart Console is OS independent and offers virtual media through
floppy, ODD, and removable disk.
Smart Server
Manager v1.1
Offering 24-7 monitoring for system health and performance.
Delivers proactive event management features including system event logging,
event handling from e-mail and SNMP Trap (PET) alerting.
Monitors onboard hardware, operating systems and virtual machines
Allows remote control from KVM and Power control
Satisfies management in web-based UI, role-based administration, and automated