GE DDC4400TWH User manual

Dryers installed in garages (if allowed by local codes) must be elevated 18
LQFKHVFPDERYHWKHÀRRU
STEP 1 - Attach two chains using Phillips head screws to each end of
XSSHUXQLWFDELQHW
STEP 2 - Locate two wall studs behind desired operating location of stacked
XQLWV
NOTE: For wall studs not appropriately spaced, see section for Alternate
0HWKRGIRU,QVWDOODWLRQRI:DOO+RRNV
STEP 3 - Screw two wall hooks into two wall studs (same height as chain
FRQQHFWLRQVRQFDELQHWRIXSSHUXQLW%RWKFKDLQVVKRXOGSXOOVWUDLJKW
EDFNWRZDOOVWXGVRUDQJOHRXWZDUG1(,7+(5FKDLQVKRXOGDQJOHLQZDUG
NOTE:7KH¿QDOFRQVWUXFWLRQPXVWZLWKVWDQGDSXOORIOEV
CAUTION: FOR PERSONAL SAFETY, STACKED UNITS MUST
BE FASTENED SECURELY TO WALL.
WARNING Personal Injury Hazard
Because of its weight and size, more than one person is required
to lift, tilt or move the washer/dryer. Failure to do so may result in
personal injury.
WARNING RISK OF FIRE
7RUHGXFHWKHULVNRIVHYHUHLQMXU\RUGHDWKIROORZDOOLQVWDOODWLRQLQVWUXFWLRQV
&ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHU
,QVWDOOWKHFORWKHVGU\HUDFFRUGLQJWRWKHVHLQVWUXFWLRQVDQGLQDFFRUGDQFHZLWKORFDOFRGHV
7KLVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
• Use
RQO\µULJLGPHWDOGXFWLQJIRUH[KDXVWLQJWKHFORWKHVGU\HUWRWKHRXWGRRUV
'2127LQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJPDWHULDOV,IÀH[LEOHPHWDOVHPLULJLGRUIRLOW\SHGXFWLVLQVWDOOHG
LWPXVWEH8/OLVWHGDQGLQVWDOOHGLQDFFRUGDQFHZLWKWKHVHLQVWUXFWLRQVDQGORFDOFRGHV)OH[LEOHYHQWLQJPDWHULDOVDUHNQRZQ
WRFROODSVHEHHDVLO\FUXVKHGDQGWUDSOLQW7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZDQGLQFUHDVHWKHULVNRI¿UH
'RQRWLQVWDOORUVWRUHWKLVDSSOLDQFHLQDQ\ORFDWLRQZKHUHLWFRXOGEHH[SRVHGWRZDWHUDQGRUZHDWKHU
6DYHWKHVHLQVWUXFWLRQV,QVWDOOHUV%HVXUHWROHDYHWKHVHLQVWUXFWLRQVZLWKWKHFXVWRPHU
INSTALLATION
INSTRUCTIONS
BEFORE YOU BEGIN Read these instructions completely and carefully.
• IMPORTANT-6DYHWKHVHLQVWUXFWLRQVIRUORFDOLQVSHFWRU·VXVH
• IMPORTANT-2EVHUYHDOOJRYHUQLQJFRGHVDQGRUGLQDQFHV
•Note to Installer -%HVXUHWROHDYHWKHVHLQVWUXFWLRQVZLWKWKHFXVWRPHU
• Note to Customer - Keep these instructions with your Owner’s Manual for future
UHIHUHQFH
%HIRUHWKHROGGU\HULVUHPRYHGIURPVHUYLFHRUGLVFDUGHGUHPRYHWKHGU\HUGRRU
6HUYLFHLQIRUPDWLRQDQGWKHZLULQJGLDJUDPDUHORFDWHGLQWKHFRQWUROFRQVROH
'RQRWDOORZFKLOGUHQRQRULQWKHDSSOLDQFH&ORVHVXSHUYLVLRQRIFKLOGUHQLV
QHFHVVDU\ZKHQWKHDSSOLDQFHLVXVHGQHDUFKLOGUHQ
,QVWDOOWKHGU\HUZKHUHWKHWHPSHUDWXUHLVDERYH)IRUVDWLVIDFWRU\RSHUDWLRQ
RIWKHGU\HUFRQWUROV\VWHP
3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQLVQRWFRYHUHGXQGHUWKH:DUUDQW\
234D2006P002 31-16312 03-13 GE
COMMERCIAL STACKED
ELECTRIC DRYERS 02
Tools and Materials You Need
6OLSMRLQWSOLHUV
6FUHZGULYHUVVORWWHGRUSKLOOLSVKHDG
&KDLQV[
µ[µVWXGV
:DOOKRRNV
7ZRµ8/UHFRJQL]HGVWUDLQUHOLHILIWKH
SRZHUVXSSO\LVIURPDGLUHFWZLUH
7ZRGU\HUSRZHUFRUGNLW8/OLVWHGUDWHG
9$ZLWKRUSURQJVLIWKHSRZHU
VXSSO\LVIURPDZDOOUHFHSWDFOH
4” diameter rigid metal duct, duct clamps,
HOERZVDQGH[KDXVWKRRG
%DVLFVDIHW\SURWHFWLRQVXFKDVVDIHW\JRJJOHV
JORYHVDQGDUPSURWHFWLRQDUHUHFRPPHQGHG
Printed in Canada
Preparing the Installation Site and Unpacking the Dryer
3UHSDUHWKHDUHDDQGH[KDXVWIRULQVWDOODWLRQRIQHZGU\HU
&KHFNWREHVXUHWKHH[LVWLQJH[WHUQDOH[KDXVWLVFOHDQDQGPHHWVDWWDFKHGLQVWDOODWLRQVSHFL¿FDWLRQV
8VLQJWKHIRXUVKLSSLQJFDUWRQFRUQHUSRVWVDVSDGGLQJWZRRQHDFKVLGHFDUHIXOO\OD\WKHGU\HURQLWVOHIWVLGHDQG
UHPRYHIRDPVKLSSLQJSDG
5HWXUQWKHGU\HUWRDQXSULJKWSRVLWLRQ
0RYHWKHGU\HUWRWKHGHVLUHGORFDWLRQ
STEP 1
STEP 2
STEP 3
Minimum Clearance Other Than Alcove or Closet Installation - Clearance to combustible surfaces and for air opening
DUHLQERWKVLGHVDQGLQUHDU&RQVLGHUDWLRQ mustEHJLYHQWRSURYLGHDGHTXDWHFOHDUDQFHIRURSHUDWLRQDQGVHUYLFH

5HPRYHWKHFRYHUQHDUWKHSRZHUFRUGHQWU\KROH
,QVWDOOµ8/UHFRJQL]HGVWUDLQUHOLHIWRSRZHUFRUGHQWU\
KROH%ULQJSRZHUFRUGWKURXJKVWUDLQUHOLHI
&RQQHFWWZR+27OLQHVWRRXWHUVFUHZV//RIWHUPLQDO
EORFN
&RQQHFW1(875$/ZKLWHOLQHWRFHQWHUVFUHZ1RI
WHUPLQDOEORFN
7LJKWHQDOOWHUPLQDOEORFNVFUHZVVHFXUHO\
3URSHUO\VHFXUHSRZHUVXSSO\FDEOHWRVWUDLQUHOLHI
5HLQVWDOOWKHFRYHU
Grounding:
•If local codes permit, be sure ground strap is connected
to neutral (centre terminal of block and to ground screw
RQUHDUIUDPH
•If local codes do not permit frame of dryer to be grounded
WRQHXWUDOUHPRYHDQGGLVFDUGJURXQGVWUDS7KHIUDPH
must be grounded by attaching a ground wire (not
supplied) to the green grounding screw on rear of dryer
and to a grounded metal cold water pipe or other
HVWDEOLVKHGJURXQG
STEP 4 - &RQQHFW ERWK GU\HUV WR SRZHU VXSSO\ 6HH
(/(&75,&$/ &211(&7,21 ,1)250$7,21 VHFWLRQ RI WKLV
LQVWUXFWLRQ
STEP 5 - &RQQHFW ERWK GU\HUV WR H[WHUQDO H[KDXVW 6HH
(;+$867,1)250$7,21VHFWLRQRIWKLVLQVWUXFWLRQ
STEP 6 - Hook both chains from upper unit to appropriate
ZDOOKRRNVWDNLQJXSDQ\VODFN
STEP 7 - $GMXVWDOOOHYHOOLQJOHJV'U\HUPXVWEHOHYHOOHGDQG
UHVW¿UPO\RQDOOOHYHOOLQJOHJV
Installation Instructions
STEP 7
Alternate Method for Installation of Wall Hooks
STEP 1
If wall studs are not correctly spaced or centered behind upper
XQLWLWPD\EHQHFHVVDU\WRDWWDFKDKRUL]RQWDOµ[µERDUGWR
WKHH[LVWLQJZDOO
STEP 2
$WWDFKZDOOKRRNVLQDSSUR[LPDWHSRVLWLRQRIWZRFKDLQVRIXSSHU
XQLWVRHDFKFKDLQSXOOVVWUDLJKWEDFNWRZDOO
NOTE: If wall is concrete or block, drill holes and use appropriate
ZDOODQFKRUV7KH¿QDOFRQVWUXFWLRQPXVWZLWKVWDQGDSXOORI
OEV
CONNECTING DRYER USING 3-WIRE CONNECTION
WARNING - FOR PERSONAL SAFETY THIS
APPLIANCE MUST BE PROPERLY GROUNDED.
WARNING: NEVER LEAVE THE COVER OFF
OF THE TERMINAL BLOCK.
N
Screws
Green Ground Screw
*URXQG6WUDS
Hot
Wire
µ8/
5HFRJQL]HG
6WUDLQ5HOLHI
$:*PLQLPXPFRSSHUFRQGXFWRUVRU9$SRZHUVXSSO\
cord kit marked for use with dryers and provided with closed loop or
VSDGHWHUPLQDOVZLWKXSWXUQHGHQGVQRWVXSSOLHG
Fuse
Hot
Wire
1HXWUDO
(white)
Strain
5HOLHI
%UDFNHW
Cover
Screw
,IUHTXLUHGE\ORFDOFRGHLQVWDOOH[WHUQDO
ground (not provided) to grounded metal,
cold water pipe, or other established
ground determined by a qualified
HOHFWULFLDQ

EXHAUST INFORMATION
• 5HPRYHWKHFRYHUQHDUWKHSRZHUFRUGHQWU\KROH
• ,QVWDOOµ8/UHFRJQL]HGVWUDLQUHOLHIWRSRZHUFRUGHQWU\
KROH%ULQJSRZHUFRUGWKURXJKVWUDLQUHOLHI
• &RQQHFWWZR+27OLQHVWRRXWHUVFUHZV//RIWHUPLQDO
EORFN
• &RQQHFW1(875$/ZKLWHOLQHWRFHQWHUVFUHZ1RIWHUPLQDO
EORFN
• Attach ground wire of the power cord with the green
JURXQGVFUHZKROHDERYHVWUDLQUHOLHIEUDFNHW
• 7LJKWHQDOOWHUPLQDOEORFNVFUHZVVHFXUHO\
• 3URSHUO\VHFXUHSRZHUVXSSO\FDEOHWRVWUDLQUHOLHI
• 5HLQVWDOOWKHFRYHU
Installation Instructions
CONNECTING DRYER USING 4-WIRE CONNECTION
WARNING - FOR PERSONAL SAFETY THIS
APPLIANCE MUST BE PROPERLY GROUNDED.
WARNING: NEVER LEAVE THE COVER OFF
OF THE TERMINAL BLOCK.
WARNING: Only a 4-conductor cord shall
be used when the appliance is installed in a location
where grounding through the neutral conductor is
prohibited. Grounding through the neutral is prohibited
for the new branch-circuit installations, mobile homes,
recreational vehicles, and areas where local codes
prohibit grounding through the neutral conduction.
WARNING - TO REDUCE THE RISK
OF FIRE OR PERSONAL INJURY:
•
7KLVFORWKHVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
8VHRQO\µULJLGPHWDOGXFWLQJIRUKRPHH[KDXVWGXFW
8VHRQO\µULJLGPHWDORU8/OLVWHGÀH[LEOHPHWDOVHPL
ULJLGRUIRLOW\SHGXFWWRFRQQHFWWKHGU\HUWRWKHKRPH
H[KDXVWGXFW,WPXVWEHLQVWDOOHGLQDFFRUGDQFHZLWK
WKHVHLQVWUXFWLRQVDQGORFDOFRGHV
'RQRWWHUPLQDWHH[KDXVWLQDFKLPQH\DZDOODFHLOLQJ
JDV YHQW FUDZO VSDFH DWWLF XQGHU DQ HQFORVHG ÀRRU
RU LQ DQ\ RWKHU FRQFHDOHG VSDFH RI D EXLOGLQJ 7KH
DFFXPXODWHGOLQWFRXOGFUHDWHDSRWHQWLDO¿UHKD]DUG
1HYHUWHUPLQDWHWKHH[KDXVWLQWRDFRPPRQGXFWZLWK
DNLWFKHQH[KDXVWV\VWHP$FRPELQDWLRQRIJUHDVHDQG
OLQWFUHDWHVDSRWHQWLDO¿UHKD]DUG
'RQRW XVHGXFW ORQJHUWKDQ VSHFL¿HGLQ WKHH[KDXVW
OHQJWKWDEOH/RQJHUGXFWVFDQDFFXPXODWHOLQWFUHDWLQJ
DSRWHQWLDO¿UHKD]DUG
1HYHULQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLV
ZLOOFDXVHOLQWWRDFFXPXODWHFUHDWLQJDSRWHQWLDO¿UH
KD]DUG
•Do not assemble ductwork with any fasteners that
H[WHQGLQWRWKHGXFW7KHVHIDVWHQHUVFDQDFFXPXODWH
OLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
'RQRWREVWUXFWLQFRPLQJRUH[KDXVWHGDLU
•
Provide an access for inspection and cleaning of the
H[KDXVW V\VWHP HVSHFLDOO\ DW WXUQV DQG MRLQWV ([KDXVW
system shall be inspected and cleaned at least once a year.
•In special installations, it may be necessary to connect
WKHGU\HUWRWKHKRXVHYHQWXVLQJDÀH[LEOHPHWDOIRLO
W\SH GXFW $ 8/OLVWHG ÀH[LEOH PHWDO IRLOW\SH GXFW
PD\EHXVHG21/<LQLQVWDOODWLRQVZKHUHULJLGPHWDORU
ÀH[LEOHPHWDOVHPLULJLGGXFWLQJFDQQRWEHXVHG$1'
where a 4” diameter can be maintained throughout
WKHHQWLUHOHQJWKRIWKHWUDQVLWLRQGXFW,Q&DQDGDDQG
LQ WKH 8QLWHG 6WDWHV RQO\ WKH ÀH[LEOH PHWDO IRLOW\SH
ducts that comply with the “Outline for Clothes Dryer
7UDQVLWLRQ'XFW6XEMHFW$µVKDOOEHXVHG
WARNING -
BEFORE PERFORMING THIS
EXHAUST INSTALLATION, BE SURE TO DISCONNECT THE
DRYER FROM ITS ELECTRICAL SUPPLY. PROTECT YOUR
HANDS AND ARMS FROM SHARP EDGES WHEN WORKING
INSIDE THE CABINET. BE SURE TO WEAR GLOVES.
REAR EXHAUST LOCATION
7KHGU\HUVFRPHVUHDG\IRUUHDUH[KDXVWLQJ8QLWVKDYH
VHSDUDWHH[KDXVWV
EXHAUST LENGTH
7KH MAXIMUM ALLOWABLE duct length and number of
EHQGVRIWKHH[KDXVWV\VWHPGHSHQGVXSRQWKHW\SHRIGXFW
QXPEHURIWXUQVWKHW\SHRIH[KDXVWKRRGZDOOFDSDQGDOO
FRQGLWLRQVQRWHGEHORZ7KHPD[LPXPGXFWOHQJWKIRUULJLG
PHWDOGXFWLVVKRZQLQWKHWDEOHEHORZ
3 1/2"
11 3/4"
Screw location
inside duct
NOTE:
Add to
vertical
dimension
the distance
between
cabinet
bottom to
ÀRRUVXUIDFH
4" DIA.
4"
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90° Elbows Rigid Metal
45 ft.
35 ft.
25 ft.
30 ft.
20 ft.
10 ft.
0
1
2
Use only for short
run installations
Rigid Metal
• )RU HYHU\ H[WUD HOERZ UHGXFH WKH DOORZDEOH YHQW V\VWHP
OHQJWKE\IW
• 7ZRHOERZVZLOOEHWUHDWHGOLNHRQHHOERZ
• )RUWKHVLGHH[KDXVWLQVWDOODWLRQVDGGRQHHOERZWRWKHFKDUW
• 7KHWRWDOYHQW V\VWHPOHQJWKLQFOXGHV DOOWKH VWUDLJKWSRUWLRQV
DQGHOERZVRIWKHV\VWHPWUDQVLWLRQGXFWLQFOXGHG
Screws
5HPRYHJURXQGVWUDS
DQGGLVFDUG.HHS
green ground screw
Hot
Wire
5HORFDWH
green
ground
screw
here
Green
Wire
µ8/
5HFRJQL]HG
6WUDLQ5HOLHI
$:*PLQLPXPFRSSHUFRQGXFWRUVRU9$SRZHUVXSSO\
cord kit marked for use with dryers and provided with closed loop or spade
WHUPLQDOVZLWKXSWXUQHGHQGVQRWVXSSOLHG
Fuse
Hot
Wire
1HXWUDO
(white)
Strain
5HOLHI
%UDFNHW
Cover
Screw

EXHAUST INFORMATION (continued)
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
7HUPLQDWHLQDPDQQHUWRSUHYHQWEDFNGUDIWVRUHQWU\RI
ELUGVRURWKHUZLOGOLIH
7HUPLQDWLRQ VKRXOG SUHVHQW PLQLPDO UHVLVWDQFH WR WKH
H[KDXVWDLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQRPDLQWHQDQFH
WRSUHYHQWFORJJLQJ
1HYHU LQVWDOO D VFUHHQ LQ RU RYHU WKH H[KDXVW GXFW 7KLV
FRXOGFDXVHOLQWEXLOGXS
:DOOFDSV PXVW EHLQVWDOOHG DWOHDVW LQ DERYHJURXQG
OHYHORUDQ\RWKHUREVWUXFWLRQZLWKWKHRSHQLQJSRLQWHGGRZQ
SEPARATION OF TURNS
)RU EHVW SHUIRUPDQFH VHSDUDWH DOO WXUQV E\ DW OHDVW IW
of straight duct, including distance between last turn and
H[KDXVWKRRGZDOOFDS,IWZRWXUQVPXVWEHFORVHUWKDQIW
GHGXFWIWIURPWKHPD[LPXPOHQJWKVVKRZQLQWKHWDEOH
IRUHDFKRFFXUUHQFH
TURNS OTHER THAN 90º
2QHWXUQRIRUOHVVPD\EHLJQRUHG
7ZRWXUQVVKRXOGEHWUHDWHGDVRQHWXUQ
(DFKWXUQRYHUVKRXOGEHWUHDWHGDVRQHWXUQ
SEALING OF JOINTS
$OO MRLQWV VKRXOG EH WLJKW WR DYRLG OHDNV 7KH PDOH HQG RI
HDFKVHFWLRQRIGXFWPXVWSRLQWDZD\IURPWKHGU\HU
7KH GXFW VKDOO QRW EH DVVHPEOHG ZLWK VFUHZV RU RWKHU
IDVWHQLQJPHDQVWKDWH[WHQGLQWRWKHGXFWDQGFDWFKOLQW
'XFWMRLQWVFDQEHPDGHDLUDQGPRLVWXUHWLJKWE\ZUDSSLQJ
WKHRYHUODSSHGMRLQWVZLWKGXFWWDSH
INSULATION
Duct work that runs through an unheated area or is near air
conditioning should be insulated to reduce condensation and
OLQWEXLOGXS
+RUL]RQWDO UXQV VKRXOG VORSH GRZQ WRZDUG WKH RXWGRRUV
LQFKSHUIRRW
4
Installation Instructions
SIDE OR BOTTOM EXHAUST
THIS DRYER COMES READY FOR REAR
EXHAUSTING. IF SPACE IS LIMITED, USE
THESE INSTRUCTIONS TO EXHAUST
DIRECTLY FROM THE SIDE OR BOTTOM OF
THE CABINET.
1HYHUXVHÀH[LEOHGXFWLQVLGHGU\HU
•
'HWDFKDQGUHPRYHWKHGHVLUHGNQRFNRXW
•
5HPRYH WKH VFUHZ LQVLGH WKH GU\HU H[KDXVW GXFW DQG VDYH
3XOOWKHGXFWRXWRIWKHGU\HU3URWHFWVKDUSHGJHVDURXQGWKH
NQRFNRXWDQGH[KDXVWRSHQLQJZLWKWKHWDSH
•&XWWKHGXFWDVVKRZQ.HHSSRUWLRQ$
•7KURXJKWKHUHDURSHQLQJORFDWHWKHWDELQWKHPLGGOHRIWKH
GU\HUEDVH/LIWWKHWDEWRDERXWXVLQJDÀDWVFUHZGULYHU
•5HFRQQHFWDQGVHFXUHWKHFXWSRUWLRQ$RIWKHGXFWWRWKH
EORZHUKRXVLQJ 0DNHVXUHWKDW WKH¿[LQJKROH LVDOLJQHG
ZLWKWKHWDELQWKHEDVH8VHWKHVFUHZRILWHPWRVHFXUH
WKHGXFWLQSODFHWKURXJKWKHWDERQWKHGU\HUEDVH
•8VHVWDQGDUGPHWDOHOERZVDQGGXFWWRFRPSOHWHH[KDXVW
V\VWHP,QVHUWVWDQGDUGHOERZDQGGXFWVWKURXJKUHDUDQG
VLGHRUERWWRPRSHQLQJV
•&RYHUWKHRSHQLQJDWWKHEDFNZLWKWKHSODWH.LW:(0
DYDLODEOHIURP\RXU/RFDO6HUYLFH3URYLGHU
PARTS AVAILABLE FROM LOCAL SERVICE
ORGANIZATION
•5LJLG0HWDO'XFW&RPSRQHQWV
:;;µ;·'XFW
:;;µ[·'XFW
:;;µ(OERZ
:;;$OXPLQXP+RRG
•)OH[LEOH0HWDO'XFW&RPSRQHQWV
:;;µGLD)OH[LEOH0HWDO6HPL5LJLG
8//LVWHG7UDQVLWLRQ'XFWLQFOXGHVHOERZV
9
"
AB
FIXING HOLE
WARNING-NEVER LEAVE THE
BACK OPENING WITHOUT THE PLATE.
ALCOVE OR CLOSET INSTALLATION
•If your dryer is approved for installation in an alcove or
FORVHWLWZLOOEHVWDWHGRQDODEHORQWKHGU\HUEDFN
•7KH GU\HU MUST EH YHQWHG WR WKH RXWGRRUV 6HH WKH
EXHAUST INFORMATIONVHFWLRQ
•0LQLPXP FOHDUDQFH IURP FRPEXVWLEOH VXUIDFHV DQG QRQ
FRPEXVWLEOHVXUIDFHVIRUDLULQWDNHSXUSRVHVLV
LQHLWKHUVLGH
LQIURQWDQGUHDU
NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT THE REAR OF
THE DRYER, MINIMUM CLEARANCE FROM THE WALL IS 5.5 in.
•0LQLPXP YHUWLFDO VSDFH IURP ÀRRU WR RYHUKHDG FDELQHWV
FHLOLQJHWFLVLQ
•Closet doors must be louvered or otherwise ventilated and
PXVWFRQWDLQDPLQLPXPRIVTLQRIRSHQDUHDHTXDOO\
GLVWULEXWHG,IWKHFORVHWFRQWDLQVERWKDZDVKHUDQGDGU\HU
GRRUVPXVWFRQWDLQDPLQLPXPRIVTLQRIRSHQDUHD
HTXDOO\GLVWULEXWHG
7KHFORVHWVKRXOGEHYHQWHGWRWKHRXWGRRUVWRSUHYHQWJDV
SRFNHWLQJLQFDVHRIDJDVOHDNLQWKHVXSSO\OLQH
1R RWKHU IXHOEXUQLQJ DSSOLDQFH VKDOO EH LQVWDOOHG LQ WKH
VDPHFORVHWZLWKWKHGU\HU
Table of contents
Other GE Dryer manuals
Popular Dryer manuals by other brands

Campbell Hausfeld
Campbell Hausfeld CE7000PB Mounting instructions

ELEKTRA
ELEKTRA CX Series installation manual

Clas Ohlson
Clas Ohlson SD-016 manual

Kenmore
Kenmore 110.8708 Use & care guide

Kenmore
Kenmore 110.C67132 411 Series Use & care guide

MSW Motor Technics
MSW Motor Technics MSW-IPD-1000-1W user manual