MATERIALS YOU WILL NEED
WARNING RISK OF FIRE
7RUHGXFHWKHULVNRIVHYHUHLQMXU\RUGHDWKIROORZDOO
LQVWDOODWLRQLQVWUXFWLRQV
&ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HG
LQVWDOOHU
,QVWDOOWKHFORWKHVGU\HUDFFRUGLQJWRWKHVHLQVWUXFWLRQVDQG
LQDFFRUGDQFHZLWKORFDOFRGHV,QWKHDEVHQFHRIORFDOFRGHV
LQVWDOODWLRQPXVWFRPSO\ZLWKWKH1$7,21$/(/(&75,&$/&2'(
$16,1)3$12
7KLVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
8VHRQO\µULJLGPHWDOGXFWLQJIRUH[KDXVWLQJWKHFORWKHVGU\HUWR
WKHRXWGRRUV
'2127LQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJ
PDWHULDOV,IÀH[LEOHPHWDOVHPLULJLGRUIRLOW\SHGXFWLV
LQVWDOOHGLWPXVWEH8/OLVWHGDQGLQVWDOOHGLQDFFRUGDQFHZLWK
WKHLQVWUXFWLRQVIRXQGLQ´&RQQHFWLQJ7KH'U\HU7R+RXVH9HQWµ
RQSDJHRIWKLVPDQXDO)OH[LEOHYHQWLQJPDWHULDOVDUHNQRZQ
WRFROODSVHEHHDVLO\FUXVKHGDQGWUDSOLQW7KHVHFRQGLWLRQVZLOO
REVWUXFWGU\HUDLUÀRZDQGLQFUHDVHWKHULVNRI¿UH
'RQRWLQVWDOORUVWRUHWKLVDSSOLDQFHLQDQ\ORFDWLRQZKHUHLW
FRXOGEHH[SRVHGWRZDWHUDQGRUZHDWKHU
6DYHWKHVHLQVWUXFWLRQV,QVWDOOHUV%HVXUHWROHDYHWKHVH
LQVWUXFWLRQVZLWKWKHFXVWRPHU
DETERMINE ELECTRICAL REQUIREMENTS FOR YOUR DRYER MODEL
7KLVGU\HUPXVWEHFRQQHFWHGWRDQLQGLYLGXDOEUDQFKFLUFXLWRISURSHUYROWDJHDQGIUHTXHQF\DVVSHFL¿HGRQ5DWLQJ3ODWHORFDWHGLQVLGH
GU\HUGRRUZLWKQRRWKHUDSSOLDQFHVRU¿[WXUHVDWWDFKHG
(;&(37,21
$9UHFHSWDFOHLVORFDWHGRQWKHEDFNRQWKHGU\HUDQGLVDYDLODEOHRQO\IRUXVHZLWKDZDVKHUWKDWLVDȻ[HGWRWKHGU\HUZLWKD
:')NLW,WPD\QRWEHXVHGIRUDQ\RWKHUDSSOLDQFHRUDQ\FRQGLWLRQVRWKHUWKDQVODWHGDERYH99PRGHOVRQO\
%UDQFKFLUFXLWPXVWEHSURWHFWHGE\WKHUHTXLUHGWLPHGHOD\IXVHVRUFLUFXLWEUHDNHUV9RU9LQVWDOODWLRQDPSV9LQVWDOODWLRQRUDPSV
7KHHOHFWULFDOLQVWDOODWLRQPXVWFRQIRUPWRWKHQDWLRQDODQGORFDOFRGHV
208V AND 240V MODELS ARE NOT APPROVED FOR 120V INSTALLATION.
Installation Instructions (USA only)
MODELS DSKS433 AND DSKS333 MUST BE INSTALLED WITH CONTROL PANEL AT BOTTOM IN ORDER TO OPERATE ADEQUATELY.
UNPACKING AND PREPARING FOR INSTALLATION
3UHSDUHWKHDUHDDQGH[KDXVWIRULQVWDOODWLRQRIQHZGU\HU
&KHFNDQGHQVXUHWKHH[LVWLQJH[WHUQDOH[KDXVWLVFOHDQDQGPHHWVDWWDFKHGLQVWDOODWLRQVSHFL¿FDWLRQV
5HPRYHWKHOLWHUDWXUHDQGDFFHVVRULHVEDJIURPWKHGU\HUGUXP3ODFHWKHOLWHUDWXUHLQDFRQYHQLHQWSODFH
8VLQJIRDPSDGVIURPGU\HUFDUWRQWXUQGU\HUXSVLGHGRZQDVVKRZQ
,QVWDOONQREV)RUORFDWLRQUHIHUWRWKH2ZQHU·V0DQXDO
'U\HULVQRZUHDG\WREHPRXQWHGDERYHZDVKHUXVLQJDFFHVVRU\NLW
5HPRYHWKHIRDPVKLSSLQJSDGVIURPXQGHUGU\HU
0RYHWKHGU\HUWRWKHGHVLUHGORFDWLRQ
)ROORZWKHVWHSVLQWKHIROORZLQJSDJHVWRFRQQHFWWKHGU\HUWRWKHH[WHUQDOH[KDXVWDQGSRZHUVXSSO\
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT-6DYHWKHVHLQVWUXFWLRQVIRUORFDO
LQVSHFWRU·VXVH
IMPORTANT-2EVHUYHDOOJRYHUQLQJFRGHVDQG
RUGLQDQFHV
Note to Installer -%HVXUHWROHDYHWKHVHLQVWUXFWLRQV
ZLWKWKHFXVWRPHU
Note to Customer -.HHSWKHVHLQVWUXFWLRQVZLWK\RXU
2ZQHU·V0DQXDOIRUIXWXUHUHIHUHQFH
%HIRUHWKHROGGU\HULVUHPRYHGIURPVHUYLFHRU
GLVFDUGHGUHPRYHWKHGU\HUGRRU
6HUYLFHLQIRUPDWLRQDQGWKHZLULQJGLDJUDPDUHORFDWHG
LQWKHFRQWUROFRQVROH
'RQRWDOORZFKLOGUHQRQRULQWKHDSSOLDQFH&ORVH
VXSHUYLVLRQRIFKLOGUHQLVQHFHVVDU\ZKHQWKHDSSOLDQFH
LVXVHGQHDUFKLOGUHQ
,QVWDOOWKHGU\HUZKHUHWKHWHPSHUDWXUHLVDERYH)
IRUVDWLVIDFWRU\RSHUDWLRQRIWKHGU\HUFRQWUROV\VWHP
3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQLVQRW
FRYHUHGXQGHUWKH:DUUDQW\
'U\HUV LQVWDOOHG LQ JDUDJHV LI DOORZHG E\ ORFDO FRGHV
PXVWEHHOHYDWHGLQFKHVFPDERYHWKHÀRRU
TOOLS YOU WILL NEED
SLIP JOINT PLIERS FLAT BLADE AND PHILLIPS SCREWDRIVERS
GLOVES
SAFETY
GLASSES
DRYER POWER
CORD KIT
(NOT PROVIDED
WITH DRYER)
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
EXHAUST
HOOD
3/4" STRAIN RELIEF
UL RECOGNIZED
4" DIA. METAL
ELBOW
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT (IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT (RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT (IF NEEDED.) DUCT TAPE
UL RATED
120/240V,30A
WITH 3 OR 4 PRONGS.
IDENTIFY THE PLUG
TYPE AS PER THE
HOUSE RECEPTACLE
BEFORE PURCHASING
LINE CORD.
234D1588P002 31-16687 01-12 GE
STACKING KITS FOR DRYERS
(Comes with individual Installation Instructions)
Over washer
- Use Wall Mount Kit WMK-35 or
- Stack Rack DSDR24 or
- Stack Rack DSR-24
For alcove and closet depth and width
reTuirements see speci¿c kit instructions
All stacking kits are available from your
local sales outlet.
Questions? Call: 800.GE.CARES (US) RUYLVLWRXUZHEVLWHDWwww.GEAppliances.com (US)
Printed in Mexico

FOR FOUR-WIRE SUPPLY
(208V & 240V MODELS)
5HPRYHJURXQGVWUDSDQGGLVFDUG5HVFUHZJUHHQ
JURXQGLQJVFUHZLQSODFH
&RQQHFWWZR+27OLQHVWRRXWHUVFUHZV/DQG/RI
WHUPLQDOEORFN
&RQQHFW1HXWUDOOLQHWRFHQWHUVFUHZ1RIWHUPLQDOEORFN
$WWDFKJURXQGZLUHRISRZHUVXSSO\WRJUHHQJURXQGLQJ
VFUHZEHVLGHWHUPLQDOEORFN
3URSHUO\VWUDLQUHOLHIWKHFRUGVHWRUFDEOHWRWKHFDEOH
HQWU\KROHZLWK8/UHFRJQL]HGVWUDLQUHOLHI
0DNHVXUHFRUGVHWRUWKHFDEOHLVDZD\IURPWKHURWDWLQJ
GUXP5HSODFHDFFHVVSDQHO
REAR
HOT WIRE
HOT WIRE
FRONT
208V or 240V
GREEN
GROUNDING
SCREW
WHITE
NEUTRAL
WIRE
GREEN OR YELLOW
GROUND WIRE
L 1 L 2N
FOR THREE-WIRE SUPPLY
(208V & 240V MODELS)
&RQQHFWWZR+27OLQHVWRRXWHUVFUHZV/DQG/RI
WHUPLQDOEORFN
&RQQHFW1HXWUDOOLQHWRFHQWHUVFUHZ1RIWHUPLQDOEORFN
3URSHUO\VWUDLQUHOLHIWKHFRUGVHWRUFDEOHWRWKHFDEOHHQWU\
KROHZLWK8/UHFRJQL]HGVWUDLQUHOLHI
0DNHVXUHFRUGVHWRUWKHFDEOHLVDZD\IURPWKHURWDWLQJ
GUXP
5HSODFHDFFHVVSDQHO
Typical 30 amp receptacle for use where
local codes permit use of flexible type
power supply cord (pigtail).
3 WIRE RECEPTACLE
(10-30R)
REAR
HOT WIRE
HOT WIRE
FRONT
208V or 240V
GREEN
GROUNDING
SCREW
WHITE
NEUTRAL
WIRE
GROUND
STRAP
L 1 L 2N
7KHRSHUDWLQJYROWDJH9ROWV$PSHUDJH$PSVDQG
)UHTXHQF\+]RIWKLVGU\HUDUHLQGLFDWHGRQWKH5DWLQJ
3ODWHORFDWHGWRWKHULJKWRIWKHORDGLQJSRUW
&RQQHFWWKLVGU\HUWRDFLUFXLWFRUUHVSRQGLQJWRWKDW
LQGLFDWHGRQ5DWLQJ3ODWHDQGSURWHFWHGE\IXVHVRUD
FLUFXLWEUHDNHULQDFFRUGDQFHZLWKORFDOFRGHV
8VHDSRZHUVXSSO\FRUGNLWPDUNHGIRUXVHZLWKFORWKHV
GU\HU)RU9DQG9PRGHOVXVHDSRZHUVXSSO\FRUG
NLWPDUNHGIRUXVHZLWKFORWKHVGU\HUV
)RUDOWHUQDWH9RU9SRZHUVXSSO\KRRNXSSURFHHG
DVIROORZV
5HPRYHUHDUDFFHVVSDQHO
&RQQHFWVXSSO\ZLUHOHDGVWRWHUPLQDOEORFNDVVKRZQRQ
VNHWFKEHORZGHSHQGLQJRQW\SHRILQVWDOODWLRQ
0DNHVXUHVFUHZVRQWHUPLQDOEORFNDUHWLJKW
7KLVDSSOLDQFHPXVWEHJURXQGHG,QWKHHYHQWRIPDOIXQFWLRQ
RUEUHDNGRZQJURXQGLQJZLOOUHGXFHWKHULVNRIHOHFWULFVKRFN
E\SURYLGLQJDSDWKRIOHDVWUHVLVWDQFHIRUHOHFWULFDOFXUUHQW
WARNING:,PSURSHUFRQQHFWLRQRIWKH
HTXLSPHQWJURXQGLQJFRQGXFWRUFDQUHVXOWLQDULVNRIHOHFWULF
VKRFN&KHFNZLWKDTXDOL¿HGHOHFWULFLDQRUVHUYLFHPDQLI\RX
DUHLQGRXEWDVWRZKHWKHUWKHDSSOLDQFHLVSURSHUO\JURXQGHG
'RQRWPRGLI\WKHSOXJSURYLGHGZLWKWKHDSSOLDQFHLILWZLOOQRW¿W
WKHRXWOHWKDYHDSURSHURXWOHWLQVWDOOHGE\DTXDOL¿HGHOHFWULFLDQ
WARNING: $SSOLDQFHJURXQGHGWRQHXWUDO
FRQGXFWRUWKURXJKDOLQN,IXVHGLQDPRELOHKRPHDQHZ
FRQVWUXFWLRQDUHFUHDWLRQDOYHKLFOHRULIORFDOFRGHVGRQRW
SHUPLWJURXQGLQJWKURXJKQHXWUDODFRQGXFWRUFRUGRUFDEOH
DVVHPEO\IRUXVHZLWKFORWKHVGU\HUVPXVWEHXVHGZLWKWKH
IROORZLQJVSHFL¿FDWLRQV7\SH6W&DEOH0LQ9ROW
$PSZLWKFORVHGORRSWHUPLQDOVDQGVHFXUHGZLWKD8/
UHFRJQL]HGVWUDLQUHOLHI6HHPDQXIDFWXUHU·VLQVWUXFWLRQV
ELECTRICAL CONNECTION DETAILS
OBSERVE ALL GOVERNING CODES AND ORDINANCES
DO NOT USE EXTENSION CORD WITH THIS APPLIANCE
GROUNDING INSTRUCTIONS
32:(56833/<&25'
$:*0,1,080&233(5
&21'8&7256
$039:,7+
7<3(8/5(&2*1,=('
0,1,0805$7('&
25
92/723(5$7,21
25
92/76833/<
86(21/<
$03)86(6
32:(56833/<&25'
$:*0,1,080
&233(5&21'8&7256
$039:,7+&/26('
/2237(50,1$/67<3(8/
5(&2*1,=('0,1,080
5$7('&
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED. FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
,16,'(7239,(:2)'5<(5
5(029(*5281'675$3
$1'',6&$5'25
92/723(5$7,2125
92/76833/<86(
21/<$03)86(6
Typical 30 amp receptacle for use
where local codes permit use of
flexible type power supply cord
(pigtail).
Typical 30 amp cord assembly for
use where local codes do not
permit grounding through neutral.
4-WIRE RECEPTACLE (14-30R)
4-CONDUCTOR CORD
ASSEMBLY ( Type ST Cable)
X
W
G
Y

DRYER TOP VIEW
IF YOUR DRYER COMES WITH REAR EXHAUST,
TO CHANGE TO SIDE OR BOTTOM EXHAUST:
5HPRYHDFFHVVSDQHODWEDFNRIGU\HUWRJDLQDFFHVVWR
LQWHUQDOGXFWV
'LVFRQQHFWGXFWH[KDXVWIURPEORZHUKRXVLQJUHPRYH
WDSHVHFXULQJGXFW
FOR SIDE EXHAUST:
5HPRYHGHVLUHGNQRFNRXWSODWHHLWKHUULJKWRUOHIWVLGH
&XWDPPòµOHQJWKRIPPµGLDULJLG
GXFWDVVKRZQUHPRYHEXUUVIURPFXWHGJH
$WWDFKWKLVH[WHQVLRQGXFWWREORZHUKRXVLQJGXFW
$WWDFKDHOERZIDFLQJGHVLUHGRSHQLQJ
$WWDFKDVHFWLRQRIPPµGLDULJLGGXFW
WRHOERZWRSURWUXGHWKURXJKVLGHRIFDELQHW
6HDODOOMRLQWVZLWKGXFWWDSH
5HLQVWDOOUHDUDFFHVVSDQHO
FOR BOTTOM EXHAUST:
5HPRYHFRYHUSODWHDWERWWRPRIGU\HU
,QVWDOODHOERZ
6HDODOOMRLQWVZLWKGXFWWDSH
5HLQVWDOOUHDUDFFHVVSDQHO
3ODFHFRYHUSODWHUHPRYHGIURPERWWRP
RIGU\HURYHUUHDUH[KDXVWRSHQLQJ
IF YOUR DRYER COMES WITH TOP EXHAUST,
TO CHANGE TO SIDE OR REAR EXHAUST:
5HPRYHUHDUDFFHVVSDQHO
'LVFRQQHFWUHWDLQLQJSODWHDQGHOERZE\UHPRYLQJ
PRXQWLQJVFUHZIURPWKHFKDVVLVDQGUHPRYHWDSH
VHFXULQJHOERZWREORZHUKRXVLQJ
5HPRYHFRYHUSODWHIURPUHDUDFFHVVSDQHODQGSODFH
RYHUWRSH[KDXVWRSHQLQJ
FOR SIDE EXHAUST:
5HPRYHGHVLUHGNQRFNRXWSODWHHLWKHUULJKWRUOHIWVLGH
7DNHWKHGXFWSUHYLRXVO\UHPRYHGDQGFXWDPP
òµOHQJWKRIPPµGLDULJLGGXFWDVVKRZQ
UHPRYHEXUUVIURPFXWHGJH
$WWDFKWKLVH[WHQVLRQGXFWWREORZHUKRXVLQJGXFW
$WWDFKWKHHOERZIDFLQJGHVLUHGRSHQLQJ
$WWDFKDVHFWLRQRIPPµGLDULJLGGXFWWRHOERZ
WRSURWUXGHWKURXJKVLGHRIFDELQHW
6HDODOOMRLQWVZLWKGXFWWDSH
5HLQVWDOOUHDUDFFHVVSDQHO
FOR REAR EXHAUST:
&XWDPPò´OHQJWKRIPPµGLDULJLG
GXFWDVVKRZQUHPRYHEXUUVIURPFXWHGJH
$WWDFKWKLVH[WHQVLRQGXFWWREORZHUKRXVLQJ
6HDODOOMRLQWVZLWKGXFWWDSH5HLQVWDOOQHDUDFFHVVSDQHO
EXHAUST INFORMATION
WARNING - IN CANADA AND IN THE
UNITED STATES, THE REQUIRED EXHAUST DUCT
DIAMETER IS 4 in (102mm). DO NOT USE DUCT LONGER
THAN SPECIFIED IN THE EXHAUST LENGTH TABLE.
8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO
,QFUHDVHWKHGU\LQJWLPHVDQGWKHHQHUJ\FRVW
5HGXFHWKHGU\HUOLIH
$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
WARNING - BEFORE PERFORMING THIS
EXHAUST INSTALLATION, BE SURE TO DISCONNECT
THE DRYER FROM ITS ELECTRICAL SUPPLY.
The correct exhaust installation is YOUR RESPONSIBILITY. Problems
due to incorrect installation are not covered by the warranty.
5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLOWUDQVLWLRQGXFWDQG
UHSODFHZLWK8/OLVWHGWUDQVLWLRQGXFW
7KHMAXIMUM ALLOWABLEGXFWOHQJWKDQGQXPEHURIEHQGVRI
WKHH[KDXVWV\VWHPGHSHQGVXSRQWKHW\SHRIGXFWQXPEHURI
WXUQVWKHW\SHRIH[KDXVWKRRGZDOOFDSDQGDOOFRQGLWLRQVQRWHG
EHORZ7KHPD[LPXPGXFWOHQJWKIRUULJLGPHWDOGXFWLVVKRZQLQ
WKHWDEOHRQWKHQH[WSDJH
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
7HUPLQDWHLQDPDQQHUWRSUHYHQWEDFNGUDIWVRUHQWU\RIELUGVRU
RWKHUZLOGOLIH
7HUPLQDWLRQVKRXOGSUHVHQWPLQLPDOUHVLVWDQFHWRWKHH[KDXVW
DLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQRPDLQWHQDQFHWRSUHYHQW
FORJJLQJ
1HYHULQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLVFRXOG
FDXVHOLQWEXLOGXS
:DOOFDSVPXVWEHLQVWDOOHGDWOHDVWLQDERYHJURXQGOHYHORUDQ\
RWKHUREVWUXFWLRQZLWKWKHRSHQLQJSRLQWHGGRZQ
SEPARATION OF TURNS
)RUEHVWSHUIRUPDQFHVHSDUDWHDOOWXUQVE\DWOHDVWIWRIVWUDLJKW
GXFWLQFOXGLQJGLVWDQFHEHWZHHQODVWWXUQDQGH[KDXVWKRRG
TURNS OTHER THAN 90º
2QHWXUQRIRUOHVVPD\EHLJQRUHG
7ZRWXUQVVKRXOGEHWUHDWHGDVRQHWXUQ
(DFKWXUQRYHUVKRXOGEHWUHDWHGDVRQHWXUQ
SEALING OF JOINTS
$OOMRLQWVVKRXOGEHWLJKWWRDYRLGOHDNV7KHPDOHHQGRIHDFK
VHFWLRQRIGXFWPXVWSRLQWDZD\IURPWKHGU\HU
7KHGXFWVKDOOQRWEHDVVHPEOHGZLWKVFUHZVRURWKHUIDVWHQLQJ
PHDQVWKDWH[WHQGLQWRWKHGXFWDQGFDWFKOLQW
'XFWMRLQWVFDQEHPDGHDLUDQGPRLVWXUHWLJKWE\ZUDSSLQJWKH
RYHUODSSHGMRLQWVZLWKGXFWWDSH
+RUL]RQWDOUXQVVKRXOGVORSHGRZQWRZDUGWKHRXWGRRUVLQFK
SHUIRRW
INSULATION
'XFWZRUNWKDWUXQVWKURXJKDQXQKHDWHGDUHDRULVQHDUDLUFRQGLWLRQLQJ
VKRXOGEHLQVXODWHGWRUHGXFHFRQGHQVDWLRQDQGOLQWEXLOGXS
EXHAUST CONNECTION
WARNING - TO REDUCE THE RISK
OF FIRE OR PERSONAL INJURY:
7KLVFORWKHVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
8VHRQO\µULJLGPHWDOGXFWLQJIRUWKHKRPHH[KDXVWGXFW
8VH RQO\ µ ULJLG PHWDO RU 8/OLVWHG ÀH[LEOH PHWDO VHPLULJLG RU
IRLOW\SH GXFW WR FRQQHFW WKH GU\HU WR WKH KRPH H[KDXVW GXFW
,WPXVWEHLQVWDOOHGLQDFFRUGDQFHZLWKWKHLQVWUXFWLRQVIRXQGLQ
´&RQQHFWLQJWKH'U\HUWR+RXVH9HQWµRQSDJHRIWKLVPDQXDO
'R QRW WHUPLQDWH H[KDXVW LQ D FKLPQH\ D ZDOO D FHLOLQJ JDV
YHQWFUDZOVSDFHDWWLFXQGHUDQHQFORVHGÀRRURULQDQ\RWKHU
FRQFHDOHGVSDFHRIDEXLOGLQJ7KHDFFXPXODWHGOLQWFRXOGFUHDWH
DSRWHQWLDO¿UHKD]DUG
1HYHUWHUPLQDWHWKHH[KDXVWLQWRDFRPPRQGXFWZLWKDNLWFKHQ
H[KDXVW V\VWHP $ FRPELQDWLRQ RI JUHDVH DQG OLQW FUHDWHV D
SRWHQWLDO¿UHKD]DUG
'RQRWXVHGXFWORQJHUWKDQVSHFL¿HGLQWKHH[KDXVWOHQJWKWDEOH
/RQJHUGXFWVFDQDFFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
1HYHULQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLVZLOOFDXVH
OLQWWRDFFXPXODWHFUHDWLQJDSRWHQWLDO¿UHKD]DUG
'RQRWDVVHPEOHGXFWZRUNZLWKDQ\IDVWHQHUVWKDWH[WHQGLQWRWKH
GXFW 7KHVH IDVWHQHUV FDQ DFFXPXODWH OLQW FUHDWLQJ D SRWHQWLDO
¿UHKD]DUG
'RQRWREVWUXFWLQFRPLQJRUH[KDXVWHGDLU
3URYLGH DQ DFFHVV IRU LQVSHFWLRQ DQG FOHDQLQJ RI WKH H[KDXVW
V\VWHP HVSHFLDOO\ DW WXUQV DQG MRLQWV ([KDXVW V\VWHP VKDOO EH
LQVSHFWHGDQGFOHDQHGDWOHDVWRQFHD\HDU
ALTERNATE EXHAUST INSTRUCTIONS
Left knockout
Bottom
knockout
Right knockout
Blower
Front of dryer
152
mm
203 mm
(8”)
89 mm
(3½”)
6”
For Rear Exhaust
For Side Exhaust
Rigid
Metallic
Ducting
Cut Here
EXTENSION DUCT
It is importat to replace the ground clip after
cutting the exhaust duct, (on rear exhaust model)
295 mm
115 mm (4½”)
(11½”)

EXHAUST LENGTH CALCULATION
RIGID (Preferred)
3DUWVDUHDYDLODEOHIURP\RXUORFDOVHUYLFHRUJDQL]DWLRQ
:;;µ;·'XFW :;;(OERZ
:;;µ;·'XFW :;;$OXPLQXPKRRG
FLEXIBLE
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKDOOQRWH[FHHGIWP
7KHIROORZLQJNLWLVDYDLODEOHIURP\RXORFDOVHUYLFHRUJDQL]DWLRQ
.LW:;;µGLDÀH[LEOHPHWDOVHPLULJLG8/OLVWHG
WUDQVLWLRQGXFWLQFOXGHVHOERZV
ALCOVE OR CLOSET INSTALLATION
,I\RXUGU\HULVDSSURYHGIRULQVWDOODWLRQLQDQDOFRYHRUFORVHW
LWZLOOEHVWDWHGRQDODEHORQWKHGU\HUEDFN7KHLQVWDOODWLRQ
PXVWFRQIRUPWRWKHIROORZLQJVSHFL¿FDWLRQV
WARNING: TO PREVENT LARGE AMOUNTS
OF LINT AND MOISTURE FROM ACCUMULATING AND TO
MAINTAIN DRYER EFFICIENCY, THIS MACHINE MUST BE
EXHAUSTED OUTDOORS.
0LQLPXPFOHDUDQFHVEHWZHHQGU\HUFDELQHWDQGDGMDFHQW
ZDOOVRURWKHUVXUIDFHVDUH
0LQLPXP YHUWLFDO VSDFH IURP ÀRRU WR RYHUKHDG FDELQHWV
FHLOLQJHWFLVLQ
&ORVHWGRRUVPXVWEHORXYHUHGRURWKHUZLVHYHQWLODWHGDQGPXVW
FRQWDLQDWOHDVWVTXDUHLQFKHVRIRSHQDUHDHTXDOO\GLVWULEXWHG,I
WKHFORVHWFRQWDLQVERWKDZDVKHUDQGDGU\HUGRRUVPXVWFRQWDLQ
DWOHDVWVTXDUHLQFKHVRIRSHQDUHDHTXDOO\GLVWULEXWHG
NOTE TO INSTALLER - AFTER INSTALLATION CHECK
THE FOLLOWING:
(;+$867'8&70XVWPHHWVSHFVRQSDJH1RH[FHVVLYH
WXUQV1RNLQNVRUREVWUXFWLRQVWRDLUÀRZ
(;+$867+22'6KRXOGZRUNIUHHO\DQGRSHQGRZQZDUG
*5281',1*'U\HUPXVWEHSURSHUO\JURXQGHGWRFRQIRUPWR
ORFDOFRGHVDQGRUGLQDQFHUHTXLUHPHQWV
23(5$7,217XUQGU\HURQDQGFKHFNIRUKHDW
+$1'&86720(57+(2:1(5·60$18$/*LYHLQVWUXFWLRQVRQ
RSHUDWLQJWKHGU\HU$QVZHUDQ\TXHVWLRQV
*,9(7+(6(,167$//$7,21,16758&7,216WRWKHFXVWRPHU
4" DIA.
4"
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90°
Elbows Rigid
Metal Rigid
Metal
14 m (46 ft)
11 m (37 ft)
9 m (30 ft)
7 m (23 ft)
11 m (37 ft)
9 m (30 ft)
6.5 m (22 ft)
4.5 m (15 ft)
0
1
2
3
Use only for short
run installations
CONNECTING THE DRYER TO HOUSE VENT
RIGID METAL TRANSITION DUCT
)RUEHVWGU\LQJSHUIRUPDQFHDULJLGPHWDOWUDQVLWLRQGXFWLV
UHFRPPHQGHG
5LJLGPHWDOWUDQVLWLRQGXFWVUHGXFHWKHULVNRIFUXVKLQJDQG
NLQNLQJ
UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT
,IULJLGPHWDOGXFWFDQQRWEHXVHGWKHQ8/OLVWHGÀH[LEOHPHW
DOVHPLULJLGGXFWLQJFDQEHXVHG.LW:;;
1HYHU LQVWDOO ÀH[LEOH PHWDO GXFW LQ ZDOOV FHLOLQJV ÀRRUV RU
RWKHUHQFORVHGVSDFHV
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHW
P
)RU PDQ\ DSSOLFDWLRQV LQVWDOOLQJ HOERZV DW ERWK WKH GU\HU
DQGWKHZDOOLVKLJKO\UHFRPPHQGHGVHHLOOXVWUDWLRQVEHORZ
(OERZVDOORZWKHGU\HUWRVLWFORVHWRWKHZDOOZLWKRXWNLQNLQJ
DQG RU FUXVKLQJ WKH WUDQVLWLRQ GXFW PD[LPL]LQJ GU\LQJ
SHUIRUPDQFH
$YRLGUHVWLQJWKHGXFWRQVKDUSREMHFWV
UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT
,Q VSHFLDO LQVWDOODWLRQV LW PD\ EH QHFHVVDU\ WR FRQQHFW WKH
GU\HUWRWKHKRXVHYHQWXVLQJDÀH[LEOHPHWDOIRLOW\SHGXFW
$ 8/OLVWHG ÀH[LEOH PHWDO IRLOW\SH GXFW PD\ EH XVHG 21/<
LQLQVWDOODWLRQVZKHUHULJLGPHWDORUÀH[LEOHPHWDOVHPLULJLG
GXFWLQJ FDQQRW EH XVHG $1' ZKHUH D µ GLDPHWHU FDQ EH
PDLQWDLQHGWKURXJKRXWWKHHQWLUHOHQJWKRIWKHWUDQVLWLRQGXFW
,Q&DQDGDDQGWKH8QLWHG6WDWHVRQO\WKHÀH[LEOHPHWDOIRLO
W\SH GXFWV WKDW FRPSO\ ZLWK WKH ´2XWOLQH IRU &ORWKHV 'U\HU
7UDQVLWLRQ'XFW6XEMHFW$µVKDOOEHXVHG
1HYHU LQVWDOO ÀH[LEOH PHWDO GXFW LQ ZDOOV FHLOLQJV ÀRRUV RU
RWKHUHQFORVHGVSDFHV
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHW
P
$YRLGUHVWLQJWKHGXFWRQVKDUSREMHFWV
For best drying performance
6OLGHRQHHQGRIWKHGXFWRYHUWKHFORWKHVGU\HURXWOHWSLSH
6HFXUHWKHGXFWZLWKDFODPS
:LWKWKHGU\HULQLWVSHUPDQHQWSRVLWLRQH[WHQGWKHGXFWWR
LWVIXOOOHQJWK$OORZµRIGXFWWRRYHUODSWKHH[KDXVWSLSH
&XWRȺDQGUHPRYHH[FHVVGXFW.HHSWKHGXFWDVVWUDLJKWDV
SRVVLEOHIRUPD[LPXPDLUÀRZ
6HFXUHWKHGXFWWRWKHH[KDXVWSLSHZLWKWKHRWKHUFODPS
NOTE: The clearances stated above are minimums. Con-
sideration must be given to the type accessory kit used
with dryer. Refer to the speci¿c kit instruction for details.
$OFRYH &ORVHW
6LGHV µ µ
7RS µ µ
)URQW µ
5HDU µ µ
WHEN INSTALLED IN MANUFACTURED (MOBILE) HOMES
'U\HUPXVWEHH[KDXVWHGWRWKHRXWVLGH([KDXVW0867127EH
WHUPLQDWHGEHQHDWKPRELOHKRPH([KDXVWPDWHULDO0867127
VXSSRUWFRPEXVWLRQ,QVWDOODWLRQ0867FRQIRUPWR0DQXIDFWXUHG
+RPH&RQVWUXFWLRQ6DIHW\6WDQGDUG7LWOH&)53DUW
RUZKHQVXFKVWDQGDUGLVQRWDSSOLFDEOHWKH$PHULFDQ1DWLRQDO
6WDQGDUGRI0RELOH+RPHV$16,1)5$1R%)RUHOHFWULFDO
FRQQHFWLRQVHH´&RQQHFWLQJGU\HUXVLQJZLUHFRQQHFWLRQµ
USE OF CASTERS (120V PORTABLE MODELS ONLY)
)RUDSRUWDEOHLQVWDOODWLRQVFUHZFDVWHUVLQWRWKHKROHVRQWKHERWWRPRIWKH
GU\HU5HIHUWRWKH´,QVWDOODWLRQ,QVWUXFWLRQVIRUFDVWHUDVVHPEO\µVKHHWWR
LQVWDOOFDVWHUV
Other manuals for Spacemaker DSKS433EBWW
2
This manual suits for next models
3
Table of contents
Other GE Dryer manuals