Specification Revised 9/04
30" Free-Standing Electric Range
Dimensions and Installation Information (in inches)
*Dimension from wall to front of closed door handle is 27-3/
Check local codes for required breaker size.
Effective January 1, 1996, the National Electrical Code requires that new construction (not
existing) utilize a 4-conductor connection to an electric ra
Locally approved flexible service cord or conduit must be used because terminals are not
accessible after range installation. See shaded area in drawing for location of electrical outlet
box. Recommended outlet locations allow range to be installed directly against wall.
Conforms to U.L. requirements for 0" spacing for adjacent walls below countertops.
To reduce possibility of scorching walls, it is recommended a minimum of 1-1/2" spacing be
allowed from adjacent side walls to allow for possible extended, high-heat, no-load heating
Installation Information:
Before installing, consult installation instructions packed with
product for current dimensional data.
For answers to your Monogram
appliance questions, visit our website at
ge.com or call GE Answer Center
30
25
2-1/2
7-1/2
29-7/8
25-3/8
47-5/8
44-7/16
2-1/2
Acceptable electrical
outlet area
Preferred electrical
outlet area
Roughed-in dimensions
Electrical outlet locat ABC.eps
All GE ranges are equipped with
an Anti-Tip device. The installation
of this device is an important,
required step in the installation