Config. # Pump 1/Heat Recovery Pump Pump 2 Ozone Filter Cycle (Daily)
11 sp (K4-P) (K6-P) 2 x 1 hour with P1
22 sp (High speed: K4-P,low speed: K6-P) 2 x 1 hour with P1
31 sp (K4-P) 1 sp (K6-P) 2 x 1 hour with P1
3- Select spa configuration
Information between ( ) indicates which connector/tab to use. See Step 1 for connector positions. This in.yj is compatible with many
different heater wattage. Please make sure you confirm which one you have so you select the right configuration from the below chart.
Software #274, rev. 001
For complete TechBook or more information, see our website: www.geckoalliance.com
9919-101279-B
Rev. 04-2015
© Groupe Gecko Alliance Inc., 2015
All trademarks or registered trademarks
are the property of their respective owners.
Printed in Mexico
Note 1: This heat recovery system has built-in "no heat" period of 1 minute. This allows a minimum delay during which any heat demand is disabled after
the heater/pumps was shut off.
Note 2: Default current allowed by the power manage is 12A (physical breaker of 15A). P1/heater is consider 8A, P1L: 4A, P2: 4AMP and ozone: 1 Amp.
3
At first startup the keypad display
will show L 1 or LL 1.
4- Enter selection
Note: To re-enter the low level
selection menu, hold the
Pump 1 key for 30 seconds.
Note: If the keypad in use does
not have the Program key use
the Filter or Light key instead.
Use the Up/Down key to choose
the new low level configuration
number (consult the chart above).
Press the Program key to confirm
the selection.
21
Press and hold the Program key
for 20 seconds until you access
the breaker setting menu.
The values displayed by the
system correspond to 80% of the
maximum amperage capacity of
the GFCI.
5- Select breaker
Breaker setting for GFCI used.
GFCI b
40 A 32 A
30 A 24 A
20 A 16 A
15 A 12 A
Press the Program key to set
breaker rating.
Use the Up/Down key to select
the breaker value. The value can
be modified from 10 to 32 A.
Note: If the keypad in use does
not have the Program key use
the Filter or Light key instead.
Default breaker value is 32 A.
Power management will make
sure never to exceed this rating.