4. Technical specifications
Output signal Voltage Current
Accuracy (1) < ±0.5% FS
Pressure ranges (2) from 1 bar to 1000 bar (see table)
Resolution Infinite
Overpressure (without degrading performance) see table below
Pressure containment (burst test) see table below
Pressure Media Fluids compatible with Stainless Steel AISI 430F and 17-4 PH
Housing Stainless Steel AISI 304
Power supply 15...30Vdc 10...30Vdc
Dielectric strengh 250 Vdc
Zero output signal 0.1V; 0.5V; 1V (*) 4 mA (nominal)
Full scale output signal 5V; 5.5V; 10V; 10.1V; 10.5V (*) 20 mA (nominal)
Max allowed load 2 mA see load diagram
Long term stability < 0.2% FS/per year
Operating temperature range (process) -40...+125°C (-40...+257°F)
Operating temperature range (ambient) -40...+105°C (-40...+221°F)
Compensated temperature range -20...+85°C (-4...+185°F)
Storage temperature range -40...+125°C (-40...+257°F)
Temperature effects over compensated range (zero-span) ± 0.015% FS/°C typical (± 0.02% FS/°C max.)
Response time (10...90%FS) < 1 msec.
Warm-up time (3)< 30 sec.
Mounting position effects Negligible
Humidity Up to 100%RH non-condensing
Weight 80-120 gr. nominal
Mechanical shock 100g/11msec according to IEC 60068-2-27
Vibrations 20g max a 10...2000 Hz according to IEC 60068-2-6
Protections IP65/IP67 (M12 version) with female homologated connector
mounted, tightening torque 0.6Nm + low strenght threadlocker
Output short circuit and reverse polarity protection YES
CE Conformity EC Directive 2004/108/CE
Electromagnetic compatibility Emission EN61326-1/EN61326-2-3
Lifetime 10 years
(*) Other voltage values of Zero and Full Scale available on request.
NOTE: SIL2 certification is available from 0-4 bar range and above
FS = Full Scale Output
1Incl. Non-Linearity, Hysteresis, Repeatability, Zero-offset and Final-offset (acc. to IEC 61298-2)
2The operating pressure range is intended from 0.5% to 100% FS
3Time within which the rated performance is achieved
Range (bar) 1 1.6 2 2.5 4 6 10 16 20 25 40 60 100 160 200 250 400 600 1000
Overpressure
(Bar) 6 6 6 10 10 20 20 32 40 50 80 120 200 320 400 500 800 1200 1200
Burst pressure
(Bar) 9 9 9 15 15 30 40 64 80 100 160 240 400 640 800 1000 1500 1500 1500