gefran SBI-DCP-33 User manual

Instruction manual
ITALIANO - 1
Introduzione
DCP (Drive Control Position) è un protocollo utilizzato per il collega-
mento seriale, tramite l’interfaccia RS485, tra un Controller Lift e un
Controller Drive.
La scheda SBI DCP 33 supporta il protocollo DCP3 per Controller Lift
senza encoder assoluto (non tutte le funzioni) :
● controlloviacollegamentoserialeDCPanzichèI/Odigitali
● viaDCPsonotrasmessiancheimessaggidiStato,utiliperla
diagnostica
● possibilitàdiaccedereatuttiimenueparametritramitela
tastieraedisplay“hostDCP”(vedere7-Tabellaconversione
tastimasterDCPefunzioni/tastidrive).
Compatibilità rmware
LaschedaècompatibilecondrivedellaserieAVyLconrmware3.6
o superiore.
Caratteristiche dell’interfaccia DCP
Lift
Controller
Monitoring
system
Drive
Controller M
RS485
(DCP)
Hoist Motor
Incremental
encoder
Connessione via DCP
● Collegamentopunto-punto
● ControllerDriveeControllerLiftcollegativiainterfacciaRS485
(semi duplex mode)
● Baudrate: 38.400
● Databits: 8
● Parity: none
SBI-DCP-33
DCP Interface card for
AVyL drive
Italiano .... pag. 1
English ... pag. 9
Deutsch ... pag. 17

2 - ITALIANO
● Stopbits: 1
● MasterSlave:
- Controller Lift è il master
- Controller Drive è lo slave
- i messaggi sono trasferiti con ciclo di 15 ms
1 - Fissaggio e collegamento
- Spegnere il drive.
- Togliere le coperture del drive come indicato nel capitolo 4.1
delManualeIstruzionideldriveAVyL.
- LaschedaSBI-DCPpuòessereinstallatasuldriveindueposizioni;
A(consigliata) o B (nel caso siano installate altre schede opzionali
tipo EXP-...).
La scheda viene fornita con una serie di colonnine, distanziali, viti e
ilcavettonecessariperilssaggioeilcollegamento:
A - SchedaSBI-DCP33sotto la scheda di regolazione).Utilizzare le
colonnineeidistanziali(B-D)eleviti(A)forniteconlascheda.
A1 A2
A3A4

ITALIANO-3
A1:ssarelecolonnineBeidistanzialiDsulla
schedaSBI-DCP33comeindicatoingura
A2: rimuovere le 4 viti indicate
A3:ssarelaschedaSBI-DCP33sottolascheda
di regolazione avvitando le viti A sulle colonni-
neBeinserireidistanzialinei2fori.
A4:riposizionarelaschedadiregolazioneessar-
la con le 4 viti.
A5: inserire i terminali del cavo E nel connettore
XR (scheda di espansione) e nel connettore
femmina XENC (scheda di regolazione)
A6:ripristinarelecoperturedeldrive
B -
SchedaSBI-DCP33
sopra la scheda di regolazione.U
tilizzare
le colonnine (C) e le viti (A) fornite con la scheda.
B1B2
B4B5
B1:tagliarelaschedalungolalineatratteggiata
B2:rimuoverele2vitidallaschedadiregolazione
B3:inserireiterminalidelcavoEnelconnettoreXR (scheda di
espansione) e nel connettore femmina XENC (scheda di rego-
lazione)
B4/B5:
ssareleduecolonnineC,posizionarelaschedaopzionale
essarlaconlevitiA.
B6:ripristinarelecoperturedeldrive
A5

4 - ITALIANO
2 - Impostazione jumper sulla scheda di regolazione RV33-4
S3 (S3-5 e S3-6) ____ ON
altri jumper _________ default
3 - Collegamento scheda DCP (connettore 9 pin) e DCP master
DATA+ (A) __________ pin 8
DATA- (B) __________ pin 6
REF (GROUND) _____ pin 9
Schermo ___________ connettore di massa
4 - Procedura di Autotuning motore
- Chiudere il contattore tra drive e motore.
-Deveesserepresente+24Vsulmorsetto12
Eseguire la procedura utilizzando il tastierino del drive:
SETUP MODE / Autotune/Complete still oppure Complete rot,
vedere il capitolo 7 del manuale del drive.
5 - Impostazione menu (drive)
Prima di eseguire questa impostazione deve essere stata eseguita la
procedura di Autotuning (4).
Accenderel’azionamentoeselezionarelamodalitàdiregolazione
FOC (Field Oriented Control) nel caso di drive collegati a motori
asincroni.
STARTUP / Regulation mode/[1]Fieldoriented
Nel menu STARTUP / Import recipe, selezionare la ricetta User 1,
questa contiene tutti i parametri necessari per la comunicazione DCP.
Ricetta “User 1”
IPA Descrizione Valore
7106 Seq start sel Alternative inp
7117 Start alt src B2 W1 decomp
7072 Mlt spd s 0 src B8 W1 decomp
7073 Mlt spd s 1 src B9 W1 decomp
7074 Mlt spd s 2 src B10 W1 decomp
7037 Ramp ref inv src B4 W1 decomp
9340 Word1 B0 src Compare 2 output
9341 Word1 B1 src RUN cont mon
9342 Word1 B2 src Drv OL warning
9343 Word1 B3 src ALM Sequencer
9344 Word1 B4 src Spd is zero
9345 Word1 B5 src NULL
9346 Word1 B6 src BRAKE cont mon
9361 W1 decomp src SBI Drv W0 mon
8999 SBI enable Enabled
9010 Drv SBI W0 src W1 comp out
9011 Drv SBI W1 src Fault Pin
6049 Cmp 1 inp 0 src RUN cont mon
6044 Cmp 1 function I0 == I1
6046 Cmp 1 delay 2.000000
6064 Cmp 2 inp 0 src RUN cont mon
6065 Cmp 2 inp 1 src Compare 1 output
6059 Cmp 2 function I0 OR I1 OR I2

ITALIANO - 5
4068 DO 3 src B0 W1 decomp
9076 Fault reset src B0 W1 decomp
4200 CCF restart On
4201 CCF restart time 5000.000000
Quandolaricettaèstataimportata,eseguireilcomandoSAVECON-
FIG nel menu STARTUP .
Spegnereeriavviareildriveperstabilirelacomunicazioneconla
scheda DCP.
6 - Fasatura encoder
Nel caso di drive collegati a motori sincroni e nel caso sia richiesta
lafasaturadell’encoder,puòessereeseguitalafasaturaautomatica
utilizzando il tastierino master controller DCP :
- nelmenuREGULATIONPARM\Fluxcong\Magnetizcong
- selezionare Auto phase rot o Auto phase still
- attendere che venga visualizzato il messaggio “Wait ...”
- impostareilmastercontrollernellamodalità“Inspectionmode”
- dareilcomandodiStart(deveesseredatoentro10saltri-
menti la procedura viene annullata).

6-ITALIANO
7 - Tabella conversione tasti master DCP e funzioni / tasti drive
Master FSP Tasti di
controllo Riferimento di testo Funzione
Non
disponibile [START] Il tasto START controlla le funzioni Abilita e Start del drive (Com-
mand select = tasto I O).
2 X →[STOP]
Il tasto STOP controlla le funzioni Stop e Disabilita (Command
select = tasto I O) il tasto Stop resetta anche il sequenziatore in
seguito ad un allarme
Non
disponibile
Jog
[Increase] / [Jog]
Le funzioni Motopotenziometro e Marcia ad impulsi non sono
disponibili sulla versione AVyL.
[Decrease] / [Rotation control]
↓
0x08
Help
[Down arrow] / [Help]
Utilizzato per far scorrere verso il basso gli elementi del menù
durante una consultazione, le liste di selezione ed i relativi
parametri oppure per digitare dei valori in un editing numerico.
Dopo aver premuto il tasto shift, viene presentato un menù di
informazioni speciche, se disponibile. E’ possibile visionare il
menù Help con le frecce su/giù. La freccia di sinistra riporta in
modalità normale.
↑
0x10
Alarm
[Up arrow] / [Alarm]
Utilizzato per far scorrere verso l’alto gli elementi del menù
durante una consultazione, le liste di selezione ed i relativi
parametri oppure per digitare dei valori in un editing numerico.
Dopo aver premuto il tasto shift, viene attivata la modalità per
la visualizzazione della lista Allarmi. Gli allarmi attivi e quelli in
attesa di riconoscimento possono essere visionati con le frecce
su/giù. Gli allarmi possono essere riconosciuti con il tasto Enter.
La freccia di sinistra riporta in modalità normale.
←
0x04
Escape
[Left arrow] / [Escape]
Utilizzato per passare al livello successivo durante la consul-
tazione del menù; per far scorrere le cifre in modalità di editing
numerico, per ritornare in modalità normale uscendo dalla lista
allarmi o dalla modalità Help. Dopo aver premuto il tasto Shift,
viene utilizzato per uscire dall’editing numerico o dalla selezione
senza effettuare alcun cambiamento.
E
0x20
Home
Enter
[Enter] / [Home]
Utilizzato per tornare la livello precedente durante la consulta-
zione del menù; per inserire delle Selezioni o dei valori numerici
dopo la fase di editing, per dare comandi e per riconoscere gli
allarmi nella modalità lista Allarmi.
Seconda funzione Home, ritorno al menù Monitor da qualsiasi
livello del menù principale.
→
0x40
Shift
[Shift] Il tasto Shift abilita le funzioni secondarie del tastierino (Controllo
rotazione, Marcia ad impulsi, Help, Allarme,Cancella, Home).

ITALIANO - 7
8 - Messaggi Master da Controller Lift a Controller Drive
Imessaggidalcontrollerliftsonocostituitida6bytesesonocompostida:
1° 2° 3° 4° 5* 6°
Command
byte
(B10 ... B0)
Data Byte 1 Data Byte 2 Communi-
cat. Byte 1
Communi-
cat. Byte 2
Checksum
• Command byte
Ilprimobytedelmessaggioèchiamatocommandbyte,contienele
seguenti informazioni:
Bit B0 Drive controller enable
0: drive non attivo
1: drive attivato durante il travel
Bit B1 -
Bit B2 Stop switch
• ----
• ----
Bit B3 -
Bit B4 Direction of travel
0: verso l’alto
1: verso il basso
Bit B5 -
Bit B6 -
Bit B7 -
Bit B8 Multispeed 0
• ----
• ----
Bit B9 Multispeed 1
• ----
• ----
Bit B10 Multispeed 2
• ----
• ----
SBI DRW W0 , l’assegnazione dei byte è la seguente:
12 11 10 9 8 7 6 5 4 3 2 1 0
Multispeed 2
Multispeed 1
Multispeed 0
Ramp rev inv src
Start alt src
Fault reset
9 - Messaggi Slave da Controller Drive a Controller Lift
Imessaggidirispostadalcontrollerdrivesonocostituitida6bytesesono
composti da:
1° 2° 3° 4° 5* 6°
Status byte
(S7 ... S0)
Data Byte 1 Data Byte 2 Communi-
cat. Byte 1
Communi-
cat. Byte 2
Checksum

8 - ITALIANO
• Status byte
Lostatusbytecontieneleseguentiinformazioni:
Bit S0 Drive controller ready
0: drive controller non pronto per travel
1: drive controller pronto per travel
Bit S1 Travel active
0: non in travel
1: in travel
Bit S2 Advanced warning active
• temperatura del dissipatore è a meno di 10°C dalla soglia di intervento di 70°C
Bit S3 General fault active
• ...
• ...
Bit S4 Motor speed below levelling value (v < 0,3 m/s)
0 : velocità >= 0,3 m/s
1 : velocità < 0,3 m/s
Bit S5 -
Bit S6 Mechanical brake
0 : freno meccanico attivo / applicato
1 : freno meccanico non attivo / applicato
Bit S7 -
DRW SBI W0 , l’assegnazione dei byte è la seguente:
12 11 10 9 8 7 6 5 4 3 2 1 0
Brake cont mon
Null
Spd is = 0
Alt sequencer
Drw ovrl warning
Run cont mon
Compare 2 out
DRW SBI W1 , l’assegnazione dei byte è la seguente:
12 11 10 9 8 7 6 5 4 3 2 1 0
Fault pin
10 - Menu DCP
InstallandolaschedaSBI-DCP,nellalistadeiparametrideldrive
diventadisponibileilseguentemenùdisolalettura:
IPA Descrizione [Unità] Accesso Default Min Max Formato Mod.Reg.
OPTION 1
SBI DCP PROTOCOL
SBI INFO
Wrong frame cnt cnt R V-F-S-B
Software version
Versione software della scheda DCP
N/A R V-F-S-B
Compatible index N/A R V-F-S-B

Instruction manual
ENGLISH- 9
Introduction
DCP (Drive Control Position) is a protocol used for the serial con-
nection,viaRS485interface,betweenaLiftControllerandaDrive
Controller.
The SBI DCP 33 card supports the DCP3 protocol for Lift Controller
withoutabsoluteencoder(notallfunctions):
● controlviaDCPserialconnectionratherthandigitalI/O
● Statusmessages,usefulfordiagnostics,arealsotransmitted
via DCP
● possibilityofaccessingallmenusandparametersfromthe
“host DCP” keypad and display (see 7 - DCP master keys and
drivefunctions/keysconversiontable).
Firmware compatibility
ThecardiscompatiblewithAVyLdriveswithrmware3.6orlater.
Features of the DCP interface
Lift
Controller
Monitoring
system
Drive
Controller M
RS485
(DCP)
Hoist Motor
Incremental
encoder
Connection via DCP
● Point-to-pointconnection
● DriveControllerandLiftControllerconnectedviaRS485inter-
face (semi-duplex mode)
● Baudrate: 38,400
● Databits: 8
● Parity: none
SBI-DCP-33
DCP Interface card for
AVyL drive

10-ENGLISH
● Stopbits: 1
● MasterSlave:
- Lift Controller is master
- Drive Controller is slave
-messagesaresentwithcyclesof15ms
1 - Assembly and connection
- Switchthedriveoff.
- Removethecoverofthedriveasdescribedinsection4.1of
theAVyLDriveinstructionmanual.
- TheSBI-DCPcardcanbeinstalledinthedriveintwopositions:
A(recommended) or B(if other optional EXP-…-type cards have
alreadybeeninstalled).
Thecardissuppliedwiththenecessarysupports,spacers,screws
andcableforassemblyandconnection:
A - SBI-DCP33cardunder the regulation card). Use the supports
andspacers(B-D)andthescrews(A)suppliedwiththecard.
A1 A2
A3A4

ENGLISH - 11
A1:fastenthesupportsBandspacersDtothe
SBI-DCP33cardasshowninthegure
A2:removethe4screwsasshown
A3:ttheSBI-DCP33cardundertheregulation
cardbytighteningthescrewsAonthesuppor-
tsBandinsertthespacersinthe2holes.
A4: replace the regulation card and fasten this in
placeusingthe4screws.
A5:inserttheterminalsofthecableEintotheXR
connector (expansion card) and into the fema-
le XENC connector (regulation card)
A6:replacethecoversofthedrive
B -
SBI-DCP33cardon the regulation card. Use the supports (C)
andscrews(A)suppliedwiththecard.
B1B2
B4B5
B1:cutthecardalongthedashedline
B2:removethe2screwsfromtheregulationcard
B3:inserttheterminalsofthecableEintotheXRconnector
(expansion card) and into the female XENC connector (regula-
tion card)
B4/B5:xthetwosupportsC,positiontheoptionalcardandfasten
itinplaceusingthescrewsA.
B6:replacethecoversofthedrive
A5

12 - ENGLISH
2 - Jumper settings on the RV33-4 regulation card
S3 (S3-5 and S3-6) __ ON
other jumpers _______ defaul
3 – Connection of DCP card (9-pin connector) and DCP master
DATA+ (A) __________ pin 8
DATA- (B) __________ pin 6
REF (GROUND) _____ pin 9
Shield _____________ ground connector
4 - Motor Autotuning procedure
-Closethecontactorbetweenthedriveandmotor.
-+24Vmustbepresentonterminal1
Run the procedure using the keypad on the drive:
SETUP MODE / Autotune / Complete still or Complete rot, see
section 7 of the drive manual.
5 - Menu settings (drive)
TheAutotuningprocedure(4)musthavebeenexecutedbeforethis
procedure can start.
SwitchthedriveonandselecttheFOC(FieldOrientedControl)mode
for drives connected to asynchronous motors.
STARTUP / Regulation mode/[1]Fieldoriented
From STARTUP / Import recipe, select User 1,whichcontainsallthe
necessary parameters for DCP communication.
“User 1” recipe
IPA Description Value
7106 Seq start sel Alternative inp
7117 Start alt src B2 W1 decomp
7072 Mlt spd s 0 src B8 W1 decomp
7073 Mlt spd s 1 src B9 W1 decomp
7074 Mlt spd s 2 src B10 W1 decomp
7037 Ramp ref inv src B4 W1 decomp
9340 Word1 B0 src Compare 2 output
9341 Word1 B1 src RUN cont mon
9342 Word1 B2 src Drv OL warning
9343 Word1 B3 src ALM Sequencer
9344 Word1 B4 src Spd is zero
9345 Word1 B5 src NULL
9346 Word1 B6 src BRAKE cont mon
9361 W1 decomp src SBI Drv W0 mon
8999 SBI enable Enabled
9010 Drv SBI W0 src W1 comp out
9011 Drv SBI W1 src Fault Pin
6049 Cmp 1 inp 0 src RUN cont mon
6044 Cmp 1 function I0 == I1
6046 Cmp 1 delay 2.000000
6064 Cmp 2 inp 0 src RUN cont mon
6065 Cmp 2 inp 1 src Compare 1 output

ENGLISH-13
6059 Cmp 2 function I0 OR I1 OR I2
4068 DO 3 src B0 W1 decomp
9076 Fault reset src B0 W1 decomp
4200 CCF restart On
4201 CCF restart time 5000.000000
Afterimportingtherecipe,sendtheSAVECONFIGcommandfrom
the STARTUP menu.
Switchthedriveoffandthenbackonagaintoestablishthecommuni-
cationwiththeDCPcard.
6 - Encoder phasing
When using drives connected to synchronous motors and if encoder
phasingisrequired,phasingcanbeperformedautomaticallyusing
the DCP master controller keypad:
- fromREGULATIONPARM\Fluxcong\Magnetizcong
- select Auto phase rot or Auto phase still
- waituntilthe“Wait…”messageisdisplayed
- set the master controller to “Inspection mode”
- sendtheStartcommand(thismustbesentwithin10seconds,
otherwisetheprocedureiscancelled).

14 - ENGLISH
7 - DCP master keys and drive functions/keys conversion table
Master FSP Control
Keys Text reference Function
Not available [START] START key commands the drive to Enable and Start.(Command
select = I O key)
2 X →[STOP]
STOP key commands to Stop and disable
(Command select = I O key)
Stop key also resets the sequencer after an alarm event
Non
disponibile
Jog
[Increase] / [Jog]
Motor pot and Jog functions are not available on AVy L version.
[Decrease] / [Rotation control]
↓
0x08
Help
[Down arrow] / [Help]
Used to scroll down menu items in menu navigation, picklists in
selectors, or digit values in numeric editing.
After pressing shift key, an item-specic information menu is en-
tered when applicable. Help menu can be browsed with up/down
arrows. Left arrow returns to normal mode.
↑
0x10
Alarm
[Up arrow] / [Alarm]
Used to scroll up menu items in menu navigation, picklists in
selectors, or digit values in numeric editing.
After pressing Shift key, the Alarm list display mode is entered.
Active alarms and Alarms pending for acknowledge can be
browsed with up/downs arrows.
Alarms can be acknowledged whit the Enter key. Left arrow
returns to normal mode.
←
0x04
Escape
[Left arrow] / [Escape]
Used to go up one level in menu navigation; to scroll digits in
numeric edit mode, to return to normal mode from alarm list or
help modes.
After pressing shift key, it is used to Escape out of numeric edit or
selection with no change.
E
0x20
Home
Enter
[Enter] / [Home]
Used to go down one level in menu navigation; to enter Selec-
tions or numeric values after editing, to issue commands, to
acknowledge alarms in the Alarm list mode.
Home second function, return to Monitor menu from any main
menu level.
→
0x40
Shift
[Shift] Shift button enables the keypad second functions
(Rotation control, Jog, Help, Alarm, Escape, Home)

ENGLISH - 15
8 - Master messages from Lift Controller to Drive Controller
Messagesfromtheliftcontrollerconsistof6bytesandcomprise:
1° 2° 3° 4° 5* 6°
Command
byte
(B10 ... B0)
Data Byte 1 Data Byte 2 Communi-
cat. Byte 1
Communi-
cat. Byte 2
Checksum
• Command byte
Therstbyteofthemessageiscalledthecommandbyte.Itcontains
thefollowinginformation:
Bit B0 Drive controller enable
0: drive not active
1: drive activated during travel
Bit B1 -
Bit B2 Stop switch
• ----
• ----
Bit B3 -
Bit B4 Direction of travel
0: up
1: down
Bit B5 -
Bit B6 -
Bit B7 -
Bit B8 Multispeed 0
• ----
• ----
Bit B9 Multispeed 1
• ----
• ----
Bit B10 Multispeed 2
• ----
• ----
SBI DRW W0 , bytes are assigned as follows:
12 11 10 9 8 7 6 5 4 3 2 1 0
Multispeed 2
Multispeed 1
Multispeed 0
Ramp rev inv src
Start alt src
Fault reset
9 - Slave messages from Drive Controller to Lift Controller
Responsemessagesfromthedrivecontrollerconsistof6bytesand
comprise:
1° 2° 3° 4° 5* 6°
Status byte
(S7 ... S0)
Data Byte 1 Data Byte 2 Communi-
cat. Byte 1
Communi-
cat. Byte 2
Checksum

16-ENGLISH
• Status byte
Thestatusbytecontainsthefollowinginformation:
Bit S0 Drive controller ready
0: drive controller not ready for travel
1: drive controller ready for travel
Bit S1 Travel active
0: not travelling
1: travelling
Bit S2 Advanced warning active
• heat sink temperature less than 10°C from the 70°C activation limit
Bit S3 General fault active
• ...
• ...
Bit S4 Motor speed below levelling value (v < 0,3 m/s)
0 : speed >= 0,3 m/s
1 : speed < 0,3 m/s
Bit S5 -
Bit S6 Mechanical brake
0 : mechanical brake active / applied
1 : mechanical brake not active / applied
Bit S7 -
DRW SBI W0 , bytes are assigned as follows:
12 11 10 9 8 7 6 5 4 3 2 1 0
Brake cont mon
Null
Spd is = 0
Alt sequencer
Drw ovrl warning
Run cont mon
Compare 2 out
DRW SBI W1 , bytes are assigned as follows:
12 11 10 9 8 7 6 5 4 3 2 1 0
Fault pin
10 - DCP menu
WhentheSBI-DCPcardisinstalled,thefollowingread-onlymenu
becomesavailableinthelistofdriveparameters:
IPA Description [Unit] Access Default Min Max Format
Reg. Mod.
OPTION 1
SBI DCP PROTOCOL
SBI INFO
Wrong frame cnt cnt R V-F-S-B
Software version
Software version of DCP card
N/A R V-F-S-B
Compatible index N/A R V-F-S-B

Handbuch
DEUTSCH - 17
Einleitung
DCP (Drive Control Position) ist ein Protokoll für den seriellen An-
schlusszwischeneinerAufzugssteuerungundeinerAntriebssteue-
rungüberdieRS485Schnittstelle.
Die Karte SBI DCP 33 unterstützt das Protokoll DCP3 für Lift Control-
lerohneabsolutenEncoder(nichtalleFunktionen):
● SteuerungüberseriellenDCPAnschlussanstattdigitaleI/O
● überDCPwerdenauchdieStatusmeldungenübertragen,die
zur Diagnose nützlich sind
● ZugangsmöglichkeitzuallenMenüsundParameternmittels
BedieneinheitundLCD“hostDCP”(siehe7-Umwandlung-
stabelleTastenMasterDCPundFunktionen/TastenAntrieb).
Firmware-Kompatibilität
DieKarteistmitdenAntriebenausderSerieAVyLmitFirmware3.6
oderhöherkompatibel.
Merkmale der Schnittstelle DCP
Lift
Controller
Monitoring
system
Drive
Controller M
RS485
(DCP)
Hoist Motor
Incremental
encoder
Anschluss über DCP
● Punkt-zu-Punkt-Anschluss
● Antriebs-undAufzugssteuerungsindüberdieRS485Schnitt-
stelleangeschlossen(Halbduplexbetrieb)
● Baudrate: 38.400
● Datenbits: 8
● Parität: none
● Stoppbits: 1
SBI-DCP-33
Schnittstellenkarte DCP
für Antrieb AVyL

18 - DEUTSCH
● MasterSlave:
-DieAufzugssteuerungistderMaster
-DieAntriebssteuerungistderSlave
-DieMeldungenwerdenim15ms-Zyklusübertragen
1 - Befestigung und Anschluss
- Antriebausschalten.
- DieAntriebsabdeckungengemäßdenAngabenausKapitel
4.1imHandbuchzumAVyL-Antriebentfernen.
- DieSBI-DCP-KartekannaufdemAntriebinzweiPositioneninstal-
liertwerden;A(empfohlen) oder B (falls andere optionale Karten
wieEXP-...installiertsind).
DieKartewirdmitdenfürBefestigungundAnschlusserforderlichen
Stiften,Ausgleichscheiben,SchraubenundKabelgeliefert.
A -
KarteSBI-DCP33unter der Reglerkarte. Die mit der Karte mitgelie-
fertenStifte,Ausgleichscheiben(B-D)undSchrauben(A)verwenden.
A1 A2
A3A4

DEUTSCH - 19
A1
:DieStifteBunddieAusgleichscheibenDan
derKarteSBI-DCP33lautAbbildungbefestigen
A2:Die4angegebenenSchraubenentfernen
A3:DieKarteSBI-DCP33unterderReglerkarte
befestigen;dieSchraubenAandieStifteB
schraubenunddieAusgleichscheibenindie2
Bohrungeneinsetzen.
A4:DieReglerkartewiedereinsetzenundmitden
4Schraubenbefestigen.
A5:DieEndstückedesKabelsEindenSteckver-
binderXR(Erweiterungskarte)unddieStec-
kerbuchseXENC (Reglerkarte) einstecken
A6:DieAbdeckungenwiederaufdenAntrieb
aufsetzen
B -
KarteSBI-DCP33über der Reglerkarte. Die mit der Karte mitgelie-
fertenStifte(C)undSchrauben(A)verwenden.
B1B2
B4B5
B1:DieKarteentlangdergestricheltenLinieabschneiden
B2:Die2SchraubenvonderReglerkarteentfernen
B3:DieEndstückedesKabelsEindenSteckverbinderXR(Erwei-
terungskarte)unddieSteckerbuchseXENC (Reglerkarte)
einstecken
B4/B5:DiezweiStifteCbefestigen,dieoptionaleKarteindie
richtigePositionbringenundmitdenSchraubenAbefestigen.
B6:DieAbdeckungenwiederaufdenAntriebaufsetzen
A5

20-DEUTSCH
2 - Steckbrückeneinstellung auf der Karte RV33-4
S3 (S3-5 und S3-6) __ ON
andere Steckbrücken _ Voreinstellung
3 - Anschluss DCP-Karte (9-Pin-Steckverbinder) und DCP Master
DATA+ (A) __________ pin 8
DATA- (B) __________ pin 6
REF (GROUND) _____ pin 9
Abschirmung ________ Erdungsverbinder
4 - Motor-Autotuningverfahrene
-SchützzwischenAntriebundMotorschließen.
-AnKlemme12muss+24Vvorhandensein.
DasVerfahrenmitHilfederAntriebs-Bedieneinheitausführen:
SETUP MODE / Autotune / Complete still oder Complete rot, siehe
Kapitel7Antriebshandbuch.
5 - Menüeinstellung (Antrieb)
VorderVornahmedieserEinstellungmussdasAutotuning-Verfahren
(4)durchgeführtwerden.
DenAntriebeinschaltenunddenSteuermodusFOC(FieldOriented
Control)auswählen,wennderAntriebanAsynchronmotorenange-
schlossen ist.
STARTUP / Regulation mode/[1]Fieldoriented
ImMenüSTARTUP / Import recipe das Rezept User 1 markieren,
dasallenotwendigenParameterfürdieDCP-Kommunikationenthält.
Rezept “User 1”
IPA Wertbeschreibung Value
7106 Seq start sel Alternative inp
7117 Start alt src B2 W1 decomp
7072 Mlt spd s 0 src B8 W1 decomp
7073 Mlt spd s 1 src B9 W1 decomp
7074 Mlt spd s 2 src B10 W1 decomp
7037 Ramp ref inv src B4 W1 decomp
9340 Word1 B0 src Compare 2 output
9341 Word1 B1 src RUN cont mon
9342 Word1 B2 src Drv OL warning
9343 Word1 B3 src ALM Sequencer
9344 Word1 B4 src Spd is zero
9345 Word1 B5 src NULL
9346 Word1 B6 src BRAKE cont mon
9361 W1 decomp src SBI Drv W0 mon
8999 SBI enable Enabled
9010 Drv SBI W0 src W1 comp out
9011 Drv SBI W1 src Fault Pin
6049 Cmp 1 inp 0 src RUN cont mon
6044 Cmp 1 function I0 == I1
6046 Cmp 1 delay 2.000000
6064 Cmp 2 inp 0 src RUN cont mon
6065 Cmp 2 inp 1 src Compare 1 output
6059 Cmp 2 function I0 OR I1 OR I2
Table of contents