GEIGER GU0021 User manual

1
www.geiger.de EN
EN
DE Bedienungsanleitung
Operating Instructions
Manuel d’utilisation
Manual de instrucciones
Istruzioni per l’uso
EN
FR
ES
IT
M
automan
Time switch
GU0021

2Gerhard Geiger GmbH & Co. KG | 100W0654 0221
en
EN
EN
1. General information
Dear customer,
By purchasing a GEIGER time switch GU0021 you have decided
on a top quality product from GEIGER. Thank you very much for
your decision and the confidence placed in us.
GEIGER GU0021 is an electronic time switch to control a 230 V
blind or rolling shutter drive.
Please keep this information for future reference.
2. Assembly instructions
The device dimensions 50 x 50 mm allow the
assembly of the device in most standard switches
currently available on the market.
In this case both GEIGER GU0021 frames must
be replaced by a DIN intermediate frame or cover
frame selected in one of the switch programs.
The following table shows a selection of suitable
DIN intermediate frames.
Since each manufacturer has his own color palette,
minor colour differences between device and inter-
mediate frame /cover frame cannot be ruled out.
I Advice for the electrician
Please use for the installation of the
time switch a deep switch box and make
sure that the cable does not prevent the
device from locking into place.
M
automan
Mode
Reset
M
auto
man
GU0021
Intermediate frame
Terminal
Wall bracket
Cover frame

3
www.geiger.de EN
EN
3. Compatible switch programs
(ultra white color similar to RAL 9010)
Manu-
facturer
Switch range DIN Inter-
mediate frame
Color Manufacturer
Ref. Nr.
Busch-
Jaeger
Carat/Solo/Future Central disc studio white 1746/10-84
Impuls Central disc alpine white 1746/10-74
Refelex SI Central disc alpine white 1746-214-101
alpha nea/exclusive Central disc alabaster/
studio white
1746/10-24G
Berker Modul 2 Spacer polar white 1109 09
S.1/B.1/B.3/B.7 Glas Adapter ring polar white 1109 19 89
K.1/K.5 Adapter ring polar white 1108 71 09
Arsys Spacer polar white 1108 01 69
GIRA Standard 55 Distance plate pure white 0282 03
E 2/E22/Event/Esprit Distance plate pure white 0282 03
Surface switch Distance plate pure white N0282 112
S-Color Distance plate pure white 0282 40
Merten Artec Spacer polar white 5160 99
M1/Atelier Spacer polar white 517119
M-SMART/M-STAR Spacer polar white 518119
M-PLAN/M-ARC Spacer polar white 518119
JUNG CD 500 Intermediate
frame
alpine white CD 590 ZA WW
A 500/AS 500/A plus Intermediate
frame
alpine white A 590 Z WW
LS-design Intermediate
frame
alpine white LS 961 Z WW
Hager Kallysto.pur/.stil/.art Intermediate
frame
brilliant white WYA550
presto
vedder
Regina Cover ultra white 7030 R UW
Alessa Cover ultra white 2030 R UW
Fiorena Cover ultra white 3030 R UW
PEHA Standard Central plate pure white 219711
Dialog Central plate pure white 819511
Aura Central plate pure white 117511
ELSO RIVA/Scala/Fashion Combination
frame
pure white 203084
Novia Combination
frame
pure white 283164
Popp Forever Intermediate
frame
pure white 729811
Pallas Intermediate
frame
pure white 729842

4Gerhard Geiger GmbH & Co. KG | 100W0654 0221
en
EN
EN
4. Operation of the time switch
Key DOWN < 1 sec. Jog mode or STOP the motor when running
Key DOWN > 1 sec. UP operating command for 2 minutes
Key UP < 1 sec. Jog mode or STOP the motor when running
Key UP > 1 sec. UP operating command for 2 minutes
Key Mode > 2 sec. Activation of the programming mode
Key Mode < 2 sec. Change the operating mode (manual mode; auto-
matic, automatic random)
Key Reset Reset to factory settings
5. Time switch programming
Activate key mode > 2 sec. Time display flashes. After reset, factory settings
flashes (=> 12:00 h).
Set time with keys UP or
DOWN
Once the UP or DOWN key is pressed the display
stops flashing. Holding the UP or DOWN key
pressed down initiates fast running of the time
display up to 30 minute steps.
Actuate briefly mode key
to confirm time
Current UP time shows on display. Arrow UP flashes.
After reset: factory setting UP time (=> 07:00 h).
Actuate keys UP or DOWN
to set time UP
Holding the UP or DOWN key pressed down initiates
fast running of the time display up to 30 minute
steps. Arrow UP flashes.
Actuate briefly mode key
to confirm the UP time
Current DOWN time shows on display. Arrow DOWN
flashes. After reset: factory setting DOWN time
(=> 21:00 h).
Actuate keys UP or DOWN
to set time DOWN
Holding the UP or DOWN key pressed down initiates
fast running of the time display up to 30 minute
steps. Arrow DOWN flashes
Actuate briefly mode key
to confirm the DOWN time
Programming mode is exited. Time and selected
mode are displayed.
6. Factory settings
Key RESET Reset to factory setting – Enables factory setting of
operating parameters to be easily restored if needed.
Day program: UP 07:00 am, DOWN 09:00 pm
Time: 12:00 h

5
www.geiger.de EN
EN
7. Possible functional modes
Press the mode key to access one after the other the possible function modes.
There are 3 modes to choose from:
man Manual
auto Automatic1) (day program)
Automatic + random2)
1) In automatic mode, the shutter is automatically raised or lowered according to
the programmed switching times.
2) When the random generator is activated, the programmed UP and DOWN travel
times are delayed backwards within a range of 1 minute to 31 minutes.
8. Jog mode
Briefly press the direction key (up to 1 sec.) to enable the inclination of the blind
slats. The automatic mode is not exited.
9. Information for the electrician
H Caution: All work on the 230V power
system must be carried out by qualified
personnel only!
H Parallel connection of motors: please
refer to the technical data in the
operating manual supplied with the
motor.
10. Declaration of conformity
We herewith explicitly declare that this product
complies with the essential requirements and
relevant directives. It is authorised for use in all
EC member states and in Switzerland without
any need of prior registration. The Declaration of
Conformity concerning this product is available on
our website: www.geiger.de.
L
removable
terminal
N
NL
PE
Motor

6Gerhard Geiger GmbH & Co. KG | 100W0654 0221
en
EN
EN
For technical questions, please call our service team at: +49 (0) 7142 938 333.
They will be happy to assist you.
Gerhard Geiger GmbH & Co. KG
Schleifmühle 6 | D-74321 Bietigheim-Bissingen
T +49 (0) 7142 9380 | F +49 (0) 7142 938 230
info@geiger.de | www.geiger.de
11. Recycling
Recycling of packaging materials
In the interest of environmental protection, please contact your local government’s
recycling or solid waste management department to learn more about the services it
provides.
Waste disposal of electric and electronic equipment
Electronic equipment or batteries cannot be discarded along with the normal
household waste. Keep for more information on the recycling and disposal
methods envisaged by the local regulations in your area.
12. Technical Data
GEIGER time switch (GU0021)
Voltage 230 V~/50 Hz
Switching voltage 250 V AC
Switching capacity 3 A (cos phi=1)
Temperature range 0°C to +45°C
Travel time 2 min.
Changeover delay time min. 0,5 sec.
Accuracy < 5 sec. / day
Power reserve ≥ 16 hours
Terminal max. 2,5 mm²
Degree of protection IP 40
Protection class II
Subject to technical changes
Table of contents
Other GEIGER Switch manuals
Popular Switch manuals by other brands

TRENDnet
TRENDnet TEG-S2400I - DATA SHEETS Quick installation guide

Linksys
Linksys ProConnect SVIEW08 v2 Specification sheet

Allied Telesis
Allied Telesis x900-24 series Function guide

Alcatel-Lucent
Alcatel-Lucent 7210 SAS E OS user manual

SICK
SICK L25 operating instructions

Pakedge Device & Software
Pakedge Device & Software SE-8P2-EP user manual