4Gerhard Geiger GmbH & Co. KG | 100W0654 0221
en
EN
EN
4. Operation of the time switch
Key DOWN < 1 sec. Jog mode or STOP the motor when running
Key DOWN > 1 sec. UP operating command for 2 minutes
Key UP < 1 sec. Jog mode or STOP the motor when running
Key UP > 1 sec. UP operating command for 2 minutes
Key Mode > 2 sec. Activation of the programming mode
Key Mode < 2 sec. Change the operating mode (manual mode; auto-
matic, automatic random)
Key Reset Reset to factory settings
5. Time switch programming
Activate key mode > 2 sec. Time display flashes. After reset, factory settings
flashes (=> 12:00 h).
Set time with keys UP or
DOWN
Once the UP or DOWN key is pressed the display
stops flashing. Holding the UP or DOWN key
pressed down initiates fast running of the time
display up to 30 minute steps.
Actuate briefly mode key
to confirm time
Current UP time shows on display. Arrow UP flashes.
After reset: factory setting UP time (=> 07:00 h).
Actuate keys UP or DOWN
to set time UP
Holding the UP or DOWN key pressed down initiates
fast running of the time display up to 30 minute
steps. Arrow UP flashes.
Actuate briefly mode key
to confirm the UP time
Current DOWN time shows on display. Arrow DOWN
flashes. After reset: factory setting DOWN time
(=> 21:00 h).
Actuate keys UP or DOWN
to set time DOWN
Holding the UP or DOWN key pressed down initiates
fast running of the time display up to 30 minute
steps. Arrow DOWN flashes
Actuate briefly mode key
to confirm the DOWN time
Programming mode is exited. Time and selected
mode are displayed.
6. Factory settings
Key RESET Reset to factory setting – Enables factory setting of
operating parameters to be easily restored if needed.
Day program: UP 07:00 am, DOWN 09:00 pm
Time: 12:00 h