Thank you for purchasing our smoke alarm!
Please read these instructions carefully and store them in a safe place
where you can access them easily.
Product description and intended use
This is a smoke alarm with an optical sensor for installation in residential
buildings, apartments, and rooms with residential-like use. Smoke
alarmsare designed to provide an early warning of fire smoke and fires
to persons present, so that these persons can react appropriately to the
hazardous event. Always consult local regulations for smoke alarms.
Led indicator
Test &
activation
button
Sound output
Product specifications
Detection method : Optical sensor
Power supply : Sealed battery (3V DC)
Battery lifetime : 10 years
Alarm volume : ≥85 dB (A) at 3meters
Alarm sensitivity : 0,105 - 0,155 dB/m
Monitored area : 40 m²
Operating temperature : 0°C - 40 °C
Operating humidity : < 93 %
Date of replacement : See product label
Individual alarm indicator : Yes
Alarm silence facility : Yes | Hush time: 5-15 minutes
Low battery warning : Yes
Low battery silence facility : Yes | Hush time: 10 hours
Installation in leisure
accommodation vehicles : Yes
Mounting location : Ceiling or wall
Interconnectable : No
Warnings:
•
To prevent injury, this apparatus must be securely attached to the
ceiling/wall in accordance with the installation instructions.
•
Batteries should not be exposed to excessive heat such as
sunshine, fire or the like.
•
Do not paint or cover the smoke alarm.
Where to install a smoke alarm
Smoke alarms must be installed in such a way that they can be reached
unhindered by the fire smoke so that fires can be reliably detected during
the development phase.
•
Install at least in sleeping areas (especially children's rooms).
•
Install at least in escape rooms.
•
In the middle of the ceiling of a room.
•
At least 50 cm away from the wall and other objects.
•
Maximum installation height of 6 meter.
•
If ceiling installation is not possible, the smoke alarm can be installed
on the wall. The distance to the ceiling should be between 30 and 50
centimeters.
Minimum Optimal Restrictions
Where not to install a smoke alarm
•
In an environment with a high risk of draught (e.g. close to air
conditioning, fans and ventilation outlets). The movement of air
canimpair the penetration of fire smoke into the smoke alarm.
•
Areas where combustions regularly occur, such as kitchens.
•
Areas with high humidity such as bathrooms, or close to devices
suchas dish washers or washing machines.
Activation
Before commissioning the smoke alarm, it is important to activate it and
test it for correct operation.
•
Press the test button and hold it for approximately 3 seconds until
the led indicator lights up. Release the test button immediately after
this. The smoke alarm will generate a beep to indicate that it's
activated.
•
Test the correct activation of your smoke alarm by pressing the test
button. If no sound is generated, the smoke alarm is not activated
properly and should not be used!
Mounting
•
Place the mounting plate on the desired installation location and mark
where the holes should be drilled.
•
Drill two holes with a diameter of 5 millimeters.
•
Push the plastic plugs into the holes.
•
Remove the fixing plug
from the mounting
plate (if necessary, use
a screwdriver for this).
•
Insert the screws into
the mounting plate
and tighten them
firmly into the plugs.
•
Place the smoke alarm
on the mounting
bracket and secure it
by turning it clockwise.
•
Insert the fixing plug
into the hole between
the mounting plate and
the smoke alarm to fix
your alarm.
•
Test the correct
operation of your
smoke alarm by
pressing the test
button. If no sound is
generated, the smoke
alarm is not
functioning properly
and should not be
used!