To START your generator from propane BBQ tanks, connect the supplied regulator hose to
oth the propane tank and generator. Slowly turn on the propane tank. If you hear a “ting”
sound as you turn on the BBQ valve you may have actuated the tank’s excess flow valve. If
this happens, either wait a moment for it to automatically reset or you will have to turn off tank
valve and repeat this step slower. To connect to larger propane tanks with regulators already
on them or natural gas connect the straight-through hose to oth the generator and supply line
quick disconnects.
Note that your generator has a secondary propane & natural gas fuel lock-off solenoid inside.
Because of this, you must jump start this generator with a car attery or equivalent if needed.
Also, note that it may take several successive attempts to start your generator y any means
ased on your fuel hose length This is ecause there will e air trapped in the hose when first
connected that will have to work through efore the generator receives pure fuel.
To STOP your generator, we recommend that you turn off what you are powering (generator
load), then turn off the gas supply, then turn off the key. This is a est practice when possi le
to minimize potential accidents and removes the smell of fuel from your hose when
disconnecting it.
How to start your generator and STOP your generator
Troubleshooting
Generator won’t start
1. Make sure the generator’s fuel selection switch matches the fuel you are using
2. Check that your attery is charged.
If the display turns off or you hear just a “clunk”
sound ut it does not turn over, your attery is either ad or not charged enough. If
needed, you can either jump start the attery or use a attery charger to charge it.
3. Check that propane tank hose connection is fully screwed onto tank tightly.
4. Turn your propane tank off then ack on slowly to check/reset tank excess flow valve.
5. Check that your air cleaner element is not flooded with oil. This can happen if your
generator tips over. If it is, squeeze filter etween paper towels, then properly
dispose of oily paper towels. (oily rags can spontaneously com ust in gar age or in
pile - hang until dry, then soak with water and detergent efore discarding)
6. Check that your tank isn’t empty, or near empty or has tipped over. If your propane
tank tipped over, the tank valve may freeze up. Return tank to upright position and let
it sit for a while without use to let valve thaw and/or drain.
7. Check the status lights on Genconnex EFI control ox located at the ottom of the oil
fill side door. The green power light should e on when the start utton is pressed.
There are two lights to show which fuel the EFI controller senses you have selected,
a light that lights if the O2 sensor signal is poor or too low, and a light that lights up if
the altitude sensor is a ove 10,000 feet or damaged.
Safety Infor ation
NOTICE:
This section is intended to augment safety information in the original Honda
OEM manual. Read the Honda Owner’s Manual efore operating
this generator.
DANGER:
Failure to follow instructions ay result in explosion or fire causing
property da age, serious injury or death.
DO NOT attempt to use damaged (including ut not limited to kinked, cut, chewed or plugged)
equipment and hoses. See your local LP or Natural Gas dealer for repairs.
DO NOT operate a generator inside your home, garage, or place of usiness. It must e
used outdoors at all times with all near y doors and windows closed. The National Fire
Code requires the generator e a minimum of 5 feet from any structure and highly
recommends a minimum distance of 10 feet to any openings including windows and doors.
DO NOT attempt to make repairs yourself
DO NOT connect to non-approved tanks or systems
DO NOT use an open flame to check for gas leaks
DO NOT perform your own gas pipe installation or repair without a proper license
DO NOT let fuel hose/regulator or tank come in direct contact with exhaust pipe
DO NOT make any alterations or modifications to any natural gas or propane supply. You must
use a licensed gas fitter/plum er and follow all state and local codes.
DO NOT store propane tanks in your home or garage etc.
INSPECT all hoses and connections prior to use
per generator output rating
(assuming 1/2-3/4 average rated load)
> 10 Deg F
2kW 20l tank,
3kW 30l tank,
7kW 60l tank
10 to -10 Deg F
2kW 30l tank
3kW 40l tank
7kW 100l tank
-10 to -20 Deg F
2kW 40l tank
3lW 60l tank
7kW 100l tanks
PROPANE TANK SIZING GUIDELINES
Propane tanks vaporize the fuel inside at a rate ased on the rate of heat a sor ed from the
tanks steel shell. The colder the temperature the slower the propane vaporizes until at some
point the generator is requiring more vapor per minute than the tank can produce. This will
cause the generator to turn off or run very poorly.
1. Make sure oth side doors are latched close.
2. Make sure the attery door is installed and screwed close. Note there is a cutout
in the top of the door for remotes and external attery leads.
3. Do not start your generator in ECO mode. Let it warm up 5 minutes first.
Generator runs rough