GenePro, Inc. Page 2
6064 McKee Rd, Fitchburg, WI 53719 sales@genepro-inc.com
Controller Operation
Press the up or down arrow button to change SP1 (if SP1
doesn’t change, refer to the next section ‘Unlocking the Con-
troller’)
Press the up and down arrows at the same time when finished
to display the current temperature.
Adjusting the Operating Temperature
If an operating temperature other than 36.0oC is desired, take
the following steps to adjust the set point.
Press the yellow button on the left of the controller until the
controller displays ‘SP1.’
Now press either the up or down arrow ONCE, this will display
the set point.
During normal operation of the water jacketed vat, a heater is
used to maintain the operating temperature of the unit.
When the indicator O1 is illuminated, the heating unit is run-
ning.
For Service Call: (877) 270-1250 Page 3
6064 McKee Rd, Fitchburg, WI 53719 sales@genepro-inc.com
Unlocking the Controller
If the operating temperature cannot be adjusted as described
in the previous section, it may be necessary to unlock the con-
troller before proceeding.
Press the yellow button on the left of the controller repeatedly
until the controller displays ‘LocK.’
Press the up or down arrow buttons until ‘uSEr’ is displayed.
Press both arrow buttons at the same time to display current
temperature.
Auto-tuning the Controller
Autotuning should be done upon setup when the water-
jacket is full and has reached operating temperature.
With the controller unlocked, press the left button repeat-
edly until “A-T” is displayed.
Press and hold the left button until A-T starts flashing.
Leave the controller alone until it stops.