GeneralAire®
Installation, Operation & Maintenance Manual
Model 1300 Dehumidifier
07 / 2011

TableofContentsPage233458999101112SafetySpecificationsOperationInstallationElectricalInitialSetUpMaintenanceWiringDiagramDimensionsPartsListingWarrantyTroubleshootingSafetyInstructionsReadandsavetheseimportantsafetyinstructionsTheinstallationoperationandmaintenanceinstructionsmustbecarefullyfollowedwhileinstallingandoperatingthedehumidifierProperadherencetotheseinstructionsisessentialtoobtainmaximumbenefitfromyourdehumidifierDANGER120voltsmaycauseseriousinjuryfromelectricshockDisconnectelectricalpowerbeforeinstallationorservicingIfusednearapoolorspabecertainthereisnochancetheunitcouldfallintothewaterorbesplashedUnitmustbegroundedelectricallyincompliancewiththeNationalElectricCodeandlocalcodesFailuretocomplywiththiswarningcouldresultinseverepersonalinjuryordeathWARNINGCAUTIONThisdehumidifiermustbeinstalledandservicedbyaqualifiedheatingventilationandairconditioningprofessionalincompliancewithalllocalandnationalcodesImproperinstallationadjustmentalterationserviceormaintenancecancauseinjuryorpropertydamageHandleunitwithcareusingadequatemanpowerorequipmenttoliftandavoidinjurytopersonnelandorequipmentFailuretoinstallthisdehumidifierincompliancewiththeinstructionscontainedhereincouldresultinunsatisfactoryoperationandordamagetotheproductThisunitisdesignedtobeinstalledindoorsinanareaprotectedfromrainormoistureItisrecommendedadrainpanbeplacedundertheunitifinstalledabovealivingareaoraboveanareawherewaterleakagecouldcausedamageForproperoperationexternalstaticpressuresacrosstheunitmustnotexceed6incheswcForprotectionofthecompressoritmustbetransportedandinstalledinanuprightpositionIftheunitwasshippedorstoredonitssidea24hoursettlingperiodintheuprightpositionisrequiredbeforerunningtheunitforthefirsttimeTemporarystoragemustbeindoorsuprightintheoriginalcartonandcompletelyshieldedfromprecipitation2

SpecificationsCapacity130Pintsperday@BOOFDBT60RHUnitPowerSupply115VoltsSinglePhase60HzMinimumCircuitAmpacity131MaximumFuse1SampOverallLength30includesductcollarsDimensionsCabinetLength24CabinetWidth25WCabinetHeight20YWeight150PoundsCompressorRotaryType1070Watts95RLA61LRARefrigerantR22FanMotor1HP11SFLAAirFlow400CFM@6incheswESPFilterWashableNylon17x23CabinetInsulationTypeEPDM1thickRValue42DuctConnections8diameterDrainConnectionsJAPrimaryandSecondaryDrainPanStainlessSteelAllspecificationsandperformancedataaresubjecttochangewithoutnoticeOperationThefunctionoftheDH130AdehumidifieristoreducetheindoorhumiditylevelsandincreasecomfortItisahighcapacitydehumidifierabletoremove130pintsofwaterperdayBOOFDBT60RHAhumiditysensordehumidistatsenseswhentherelativehumidityRHisabovethesetpointexample50RHandsignalsthedehumidifiertooperateuntiltherelativehumiditylevelhasbeenloweredtothesetpointIftheroomthermostatcallsforheatingorcoolingthedehumidifierwillstopandwillnotoperateWhentheroomthermostatissatisfiedandtheheatingorairconditionerisstoppedthedehumidifierwillresumeoperationiftherelativehumidityRHisabovethesetpointIfthedehumidistatissatisfiedwhentheheatingorcoolingceasesthedehumidifierwillremainstoppedIftheswitchonthethermostatfortheheatingorairconditioningsystemisplacedintheOFFpositionthedehumidifierwillstilloperateiftherelativehumidityisabovethedehumidistatsetpointToturnoffthedehumidifiermovethedehumidistatdialtotheOFFpositionTurningthedehumidifieroffisnotrecommendedasitreducestheeffectivenessoftheoveralldehumidificationsystemControlsUnitMountedDehumidistatTheunitiscontrolledbytheintegralcontrolsystemwhichoperatestheinternalfanapproximately15minuteseachhourtosampletheairinthesystemTheairsamplepassesovertheunitmountedhumiditysensorwhichshouldbesetatapproximatelymidlevelAfterathreeminutedelayifthehumiditylevelinthesampledairisgreaterthanthesetpointthedehumidifierwillturnonThedehumidifierwilloperateuntilthehumiditylevelreachesthehumiditysensorsetpointOptionalWallControlledOehumidistatWhenthewallcontrolleddehumidistatisusedtheunitmountedcontrolmustbesettothelowestrelativehumidityRHsettingandneverreadjustedThewallcontrolleddehumidistatshouldbesetinthecomfortareaofapproximately50relativehumidityWhenthedehumidistatsensesthattherelativehumidityinthespaceisaboveitssetpointanelectricalcontactwithinthedehumidistatclosescausingthedehumidifiertostartTheunitdehumidifieroperatesuntiltherelativehumidityhasbeenloweredtothesetpoint3

FrostControlInsomecasesofprolongedoperationoriftheconditionedspaceisrelativelycoolfrostwillaccumulateonthecoilIcemayeventuallycoverthecoilblocktheairflowandstopproperoperationIfthecoilbecomesunacceptablycoldforatleasttenminutesasensormountedonthecoilwillstopthecompressorTopreventfrostbuildupbeyondanacceptablelevelthefanwillcontinuetooperatetomeltanyaccumulatediceOncetheicehasmeltedandthecoiliswarmthecompressorwillrestartandthedehumidificationprocesswillresumeFloatSwitchInadditiontotheprimaryandsecondarycondensatedrainlinestheDH130AisequippedwithafloatswitchIfthedrainlinesshouldbecomecloggedorrestrictedoverflowofwaterwilloccurThisswitchdisablesthecompressorandstopswaterproductionOncetheblockagehasbeenclearedtheswitchwillallowtheunittoreturntonormaloperationInstallationlocationWhenchoosinganinstallationlocationconsidertheaccessibilityforservicecondensatedrainavailabilityandpowerconnectionTheproperlocationisveryimportantasitwilldeterminetheoveralllengthoftheconnectionductsLocatetheunitascloseaspossibletotheindoorportionoftheheatingorairconditioningsystemThedehumidifiermaybeplacedabovebeloworlevelwiththeheatingorairconditioningsystemPlacetheunitinalocationthatwillallowaminimumof22clearanceforfilterremovalandserviceaccessThisclearanceisrequiredononlyonesideoftheunitsincethefilterisremovablefromeithersideAllowadequateclearancetowallsforunitserviceThishumidifierisdesignedtobeinstalledindoorsinaspacethatisprotectedfromrainormoisture5upendedunitutiljzjngoptionalhangingkitMountingThedehumidifiermaybemountedonaflatsurfaceorsuspendedDonotmounttheunitdirectlyonstructuralmembersIfmountedonaflatsurfaceusethefourrubbermountingfeetprovidedTominimizeunwantedvibrationselectalevelmountingsurfaceAdjustthemountingfeettocompensateforanysurfaceirregularitiesMakecertainthattheunitissittingonallfourmountingfeetTosuspendtheunitaseparatehangerkitHD14isrequiredThiskitconsistsoffourbracketsandfourrubberisolatorsThreadedrodsorothermeansofsuspensionmustbeprovidedbytheinstallerandmustbeselectedbasedontheunitweightlS0IbsandincompliancewithlocalcodeslIIiThisunitisequippedwithaprimaryandsecondarydrainalongwithafloatswitchtopreventoverflowofwaterfromtheunitItisrecommendedadrainpanbeplacedundertheunitifinstalledabovealivingareaoraboveanareawherewaterleakagecouldcausedamageCondensateDrainTheDH130AisequippedwithprimaryandsecondarycondensatedrainlineconnectionsThedrainsmustbetrappedexternaltotheunitandconnectedpernationalandlocalplumbingcodestodrainlinesthatwillcarryawaythewatercollectedbythedehumidifierTopreventwaterbeingremovedfromthetrapswhentheairconditioningunitisrunningthetrapdimensionsmustbeequivalenttothedimensionofthetrapontheassociatedairconditioningsystemTheprimaryandsecondarydrainlinesmustbeattachedtothetrapoutletsandpitchedawayfromtheunitaminimumof18perfoottoassureproperwaterremovalItisrecommendedadrainpanbeplacedundertheunitifinstalledabovealivingareaoraboveanareawherewaterleakagecouldcausedamageTheprimarycondensatedrainmustberoutedaccordingtonationalandlocalcodesThesecondarycondensatedrainlinemustdischargetoavisiblelocationtoalerttheenduserthataproblemexistswithdehumidifiersprimarydrainagesystemDuctingTheunitisfurnishedwithtwobeaded8roundcollarsforductconnectionstotheinletandtheoutletofthedehumidifierThesearelocatedinsidetheunitandmustbeattachedtotheunitbytheinstallerusingscrewsandgasketsorcaulkingCenterthecollarsovertheinletandoutletopeningsinthecabinetInsulatedflexibleductsincompliancewithUnderwritersLaboratorysULStandardforFactoryMadeDuctMaterialsVL78andinstalledpertheductmanufacturersrecommendationshouldbeusedtoconnectthedehumidifiertotheheatingorairconditioningsystemTheinstallationandconnectionsmustbeincompliancewithnationalandlocalcodesandbecompletelytightandleakfreeDuctsshouldbeasshortaspossiblenottoexceed100ftequivalentlengthandsupportedincompliancewiththeductmanufacturersrecommendationCAUTIONAllductconnectionsmustbesealedAnyairleakageintheductworkwilladverselyaffecttheoperationofthedehumidifierandmayleadtounsatisfactoryperformance4

DampersOptionaldampersmaybeinstalledintheoutletductinletductorinanoutsideairductThesedampersmustbeafullflowmotorizedtypeDonotuseanytypeofpressureoperateddamperasunacceptablepressuredropwillaffectunitoperationAlldampersmustbeinstalledincompliancewiththedampermanufacturersrecommendationsandbeinsulatedandsealedperthesectiononductingaboveElectricalInstallationmustbeperformedbyaqualifiedservicetechnicianandmustcomplywithallnationalandlocalcodesRemovepowertothedevicebeforeinstallingorservicingtheequipmentTheelectricalsupplyrequirementsarelistedontheunitnameplateandintheSpecificationTableonpage3UseaseparatefusedbranchelectricalcircuitcontainingaproperlysizedfuseorcircuitbreakerRunthiscircuitdirectlyfromthemaincircuitboxtoanelectricaldisconnectwhichmustbereadilyaccessibleandlocatedwithinsightofthedehumidifierConnectthedisconnecttotheelectricalconnectionsinsidethedehumidifierutilizingtheholesizedfor12conduitprovidedontheenteringairendoftheunitInstallationoftheelectricalsupplylinemustbeinaccordancewiththeNationalElectricCodeANSINFPANo70latesteditionorCanadianElectricalCodePartlCSAStandardC221andlocalbuildingelectriccodesusingcopperconductorsonlyDANGERTurnoffelectricalpoweratthefuseorservicepanelbeforemakinganyelectricalconnectionsThegroundconnectionmustbecompletedbeforemakinglinevoltageconnectionsFaiiuretodosocanresultinelectricalshockseverepersonalinjuryordeathThedehumidifiermustbeinstalledsothattheelectricalcomponentsareprotectedfromwaterfromanysourceWARNINGLhotandNneutralpolaritymustbeobservedwhenmakingtheelectricalconnectiontotheunitOptionalRemoteDehumidistatThedehumidifierissuppliedwithitsownselfcontaineddehumidistatwhichincludesanairsamplingsequenceTheunitmayalsobecontrolledbyaremotedehumidistatlocatedinaconditionedspaceDonotlocatetheremotedehumidistatintheductworkItisrecommendedthattheremotedehumidistatbelocatedinanareaclosetotheheatingorairconditioningsystemthermostatoutofdraftsawayfromheatsourcesandoutofdirectsunlightItshouldbelocatedapproximatelyfivefeetabovethefloorinanareawithgoodaircirculationatanaveragetemperatureandrelativehumidityRemovethejumperonterminals51and52andconnecttheremotedehumidistatasshownontheunitconnectiondiagramDANGERThecabinetmustbepermanentlygroundedConnectthegroundwiretothegroundterminalprovidedintheunitFailuretogroundthecabinetcanresultinfireelectricalshockpersonalinjuryordeathInstallationOptionsThedehumidifiermaybeinstalledsothatthedehumidifierandthecentralheatingorairconditioningsystemfansoperateseparatelyofeachotherIndependentOperationormaybeconnectedrequiringthedehumidifierandthecentralheatingorairconditioningsystemfansoperateatthesametimeDependentOperationIndependentOperationDuctConnectionsInthisarrangementthedehumidifierisconnectedacrossorinparallelwiththeheatingorairconditioningsystemThedischargeofthedehumidifierisconnectedtothedischargeoftheheatingorairconditioningsystemTheinletconnectionofthedehumidifierisconnectedtotheinletductoftheheatingorairconditioningsystemWhenthedehumidifierisconnectedforindependentoperationtheheatingorairconditioningsystemfanandthedehumidifierfanwillnotoperateatthesametime5

ISupplAiIigoAiondilningSyITpRerrnAViewlIIMidIIOpMnINColperDehumidifierConnectedtheHeatingorAirConditioningSystemPipedParalleltoSystemCelinllFloorJootppI0OptKINCPamlRelurnAiDehumidifierSuspendedfromCeilingHeatingorAirConditioningSystemBlowerandDehumidifierDONOTOperateattheSameTimeControlsConnectionThedehumidifiercontrolsmustinterfacewiththeheatingorairconditioningsystemThisinterfaceisrequiredtodothefollowingTurnoffthedehumidifieriftheheatingorairconditioningsystemisinthecoolingorheatingmodeTurnofftheheatingorairconditioningsystemfanduringdehumidifieroperationiftheFANswitchonroomthermostathasbeenplacedintheONpositionforcontinuousoperationFivewiresrunfromtheheatingorairconditioningsystemtothedehumidifierToaccomplishthisindependentoperationinterfaceseetheUnitConnectionDiagramandthefollowingConnecttheCWandYterminalsonthedehumidifiertothecorrespondingterminalsontheheatingorairconditioningsystemDonotdisconnectanyoftheexistingwiresfromtheCWorYterminalsontheheatingorairconditioningsystemDisconnecttheexistingthermostatwirefromtheGterminalontheheatingorairconditioningsystemUsingawirenutsplicethiswiretoanewwireandthenconnecttotheG1terminalonthedehumidifierConnecttheG2terminalonthedehumidifiertotheGterminalontheheatingorairconditioningsystemAllcontrolswiringincludingconnectiontoaremotedehumidistatmustbe1822gaugeandmeetnationalandlocalelectricalcodesEntryintothedehumidifieristhrougha78diameterholelocatedontheairentryendofthedehumidifieradjacenttotheunitmounteddehumidistatNoteThisisseparatefromthepowerentryUnitConnectionDiagramIndependentOperationDEHUMIDIFIERSYSTEMDAMPERiOPTIONAL24VAC40VAMINTRANSFORMER11UNITCONNECTIONDIAGRAMINDEPENDENTOPEMTlONDEHUMIDIFIEROHoNCTHERMOSTATYWAIRHANDlERfFURNACEyWAllMOUNTODEHUMIOISTiTDOPTIONALGywC010CGwcPUCS2REMOVEJUMPERON152WHENOPTIONALDEHUMJDISTATISUSED516

DamperConnectionIfanoptionaldampersisusedinthedischargereturnductthismaybecontrolledbythedehumidifierSeeUnitConnectionDiagramIndependentOperationaboveforconnectiondetailsWhenconnectedasshownintheabovediagramthedehumidifierprovidesonlytheswitchinginterfaceforthedampersPowerforthesedevicesmustbeprovidedwithaseparatetransformernotprovidednotfromthetransformerlocatedinthedehumidifierThedampercontrolwiringmustmeetnationalandlocalelectricalcodesEntryintothedehumidifieristhroughthecontrolwireentrylocatedontheairEntryendoftheunitNoteThisisseparatefromthepowerentryDependentOperationDuctConnectionsInthisarrangementthedehumidifierisconnectedeitherupstreamordownstreamoftheheatingorairconditioningsystemBoththedischargeandthereturnofthedehumidifierareconnectedtothesamesideofthesystemWhenthedehumidifierisconnectedfordependentoperationtheheatingorairconditioningsystemfanandthedehumidifierfanmustoperateatthesametimeDehumidifierConnectedforDependentOperationwithHeatingorAirConditioningSystemPipedReturnReturnDischargeAirHeatingorAirConditioningSystemTopViewReturnAirl8axDehumidifierInstalledonFloorHeatingorAirConditioningSystemBlowerandDehumidifierMUSTOperateattheSameTimeControlsConnectionThedehumidifiercontrolsmustinterfacewiththemainheatingorairconditioningsystemThisinterfaceisrequiredtoensurethattheheatingorairconditioningsystemfanisonwhenthedehumidifierisoperatingTwowiresrunfromtheheatingorairconditioningsystemtothedehumidifierToaccomplishthisdependentoperationusetheinterfaceUnitConnectionDiagramDependentOperationbelowandthefollowingConnecttheDterminalsonthedehumidifiertotheRterminalontheheatingorairconditioningsystemDonotdisconnectanyoftheexistingwiresfromtheheatingorairconditioningsystemConnecttheDHterminalonthedehumidifiertotheGterminalontheheatingorairconditioningsystemDonotdisconnectanyoftheexistingwiresfromtheheatingorairconditioningsystemAllcontrolswiringincludingconnectiontoaremotedehumidistatmustbe1822gaugeandmustmeetnationalandlocalelectricalcodesEntryintothedehumidifieristhrougha78diameterholelocatedontheairentryendoftheunitadjacenttotheunitmounteddehumidistatNoteThisisseparatefromthepowerentryDamperConnectionAlthoughnotnecessaryifanoptionaldampersisutilizedinthedischargelreturnductthismaybecontrolledbythedehumidifierSeetheUnitConnectionDiagramDependentOperationbelowforconnectiondetailsWhenconnectedasshownintheUnitConnectionDiagramthedehumidifierprovidestheswitchinginterfaceforthedampersaswellasthelinevoltagepowertothetransformernotincludedPowerforthedampersisprovidedbythedehumidifierThedampercontrolwiringmustmeetnationalandlocalelectricalcodesEntryintothedehumidifieristhroughthecontrolwireentrylocatedontheairentryendoftheunitNoteThisisseparatefromthepowerentry7

UnitConnectionDiagramDependentOperationUNITCONNECTIONDIAGRAMDEPENDANTOPERATIONT86DEHUMIDIFiERN3DEHUMIDIFIERSYSTEMDAMPEROPTIONALAleTHIIDHERMOSTATNCEMENTJIyywWCCcGGG1RRG24S124VACTRANSFORMERTB1040VAMINDEHUMIDIFIERBYOTHERSWALLMOUNTEDOEHUMID1STATOPTIONALREMOVEJUMPERON182WHENOPTIONALOEHUMIDISTATISUSEDInitialSetUpTurnpowertothedehumidifieronAdjustthesetpointknobtoapproximately60relativehumidityForwallcontrolsadjusttheunitmountedcontroltoitsminimumrelativehumidityRHsettingandsetthewallmounteddehumidistattoadesiredlevelItisrecommendedthatitfirstbesettoapproximately60RHandthenadjustednosoonerthan24hourslatertoahigherorlowersetpointasdesiredItisrecommendedthatalladjustmentsbemadeinnomorethan3incrementsatnolessthan24hourintervalsDependingupontheconditionsthedehumidifiermayoperateforextendedperiodsespeciallywhenfirststartedorafterhavingbeenoffMaintenanceFilterThedehumidifierisequippedwithapermanentnylonmeshairfilterThisfilteriswashableandshouldbecleanedregularlyItisrecommendedtocleanthehumidifierfilteratthesametimetheheatingorairconditionerfilterisreplacedIfthefilterhasbecomeexcessivelydirtywhencleanedatthisintervalitmaybenecessarytoadjustthecleaningscheduletomorefrequentcleaningExcessdirtonthefilterwillreduceoveralleffectivenessofthedehumidifierDrainThedraintraporoutletshouldbecheckedandcleanedannuallyFlushitwithwatertoensurethedrainisclear8

EcC1taoC1c2IIIIi1lllJ0I11i1IILIIIiIIijI1e1rJqiLlidzNIIlH09lddnsdJMOdIIL@DciLdcrqI110uco1Bo08E20togg15kqSlMl51sIIiltJ1il@I14jilISIIYQjmjHVI8II1jerlIrc111liijiiiIIJIIIIII1I1ifEicg9rHljJtiJ1filWI01VSImj11iilrjlYjIIIiiuHt4VCFrrlTuJIIJIfJ1IIImilIIMI5lTrnrIIJcLIlr5WmujTJ0lrnTruIIiFA1IiLtMrij0iQBo111111IillIII1iIIidIiiiithaQ11it0ii8jiiI1iIiliseJ1U11l1iiilsvulinIIll1zQIolII1SaI1oJl1I12iIRR181eiltzv11u00Q1IjCljiIj1111111rIIIIrlifdeltilIIIlI

Dimensions3024I3ITlIII86IIIII6nIIIIil11IIiliPfIoJqJl19I112II2010112548DIA3TYPICAL5II1111I1111r1111111931112061111I1111I11111111I19TroubleshootingPROBLEMPOSSIBLESOLUTIONVerifythereispowertotheunitCheckthatanydisconnectswitchisintheONpositionCheckthatthecircuitbreakerisnottrippedaseparate1SampcircuitDehumidifierwillnotrunbreakerisrecommendedVerifythedehumidistatisnotintheOFFpositionVerifylowvoltagewiringbetweenheatingandairconditioningsystemanddehumidifieriscorrectUnitdoorswitchisnotmechanicallyactuatedduetoloosedoorDehumidifieroperatesFiltermaybedirtyCleanfilterDehumidistatsetatunrealisticallylowsettingResettoapproximately50RHcontinuouslybutdoesnotUnitwillneedtimetodrymaterialsinthebuildingbeforeeffectivelychangingthedehumidifyRHsettinoUnitisnoisyEnsureunitissittinglevelandonallfourfeetVerifyallpanelscrewsaretightEnsureunitislevelWaterdripsfromunitVerifycondensatedrainisproperlytrappedCheckforpluggedcondensatetraporcondensatelineHeatingorairconditioningsystemisOFFbutdehumidifierThisisnormaloperationaslongasthereispowertothedehumidifierrunsDehumidifiercontinuestorunChecklowvoltagewiringbetweenairconditioningunitCYandWterminalsandthewhenheatingorairconditioningsystemrunsdehumidifierConfirmthatthefloatswitchisnotstuckopenCompressorneverrunsDefectivecompressorDefectivecontrolcircuitboardAirtemperatureorhumidityhasdroppedAirfilterdirtyorairflowrestrictedUnitremovessomewaterbutDefectivedefrostthermostatinunitnotasmuchasexpectedLowrefrigerantchargeDehumidifiercoilsaredirtyAirleaksuchasaloosecoverorpanelorleaksinductwork10

ReplacementPartsItQmPartNumberDescriptionItemPartNumblrDescription1DHD114DuctSupply20DH8T14BottomPan2DHVB14PanelBlowerSupplywlnsulation21DHSD14PanelSidewithInsulation3DHBM14BaseMotor22DHSP14PanelFilterwithInsulation2Required4DHMT14Motor115V110HP3Speed23DHPP14PCBMain5DH8W14810werSetWheelHousingInlet24DHHC14SensorModuleHumiditywithHarness6DHRC14CapacitorMotor2SDHNC14KnobControl7DHDP14DrainPan26DHRI14IsolatorRubber4Required8DHSM14PanelSidewithInsulation27DHAF14FootRubberAdjustable4Required9DHC014Coil28DHDS14SwitchDoor10DHFT14Filter431x595x5mmNylon29DHCT14PanelControl11DHUF14FilterUpperGroove3031DHMH14GrommetRubberClosed78OD12DHDR14DuctReturn32DHRH14PotRHAdjustmentwithHarness13DHTR14Transformer11S24VAC24VA33DHTP14PanelTopwithInsulation14DHVR14PanelReturnAirwithInsulation34DHHG14Hanger4Requiredt5DHLF14FilterLowerGroove35DHTS14TerminalStripTB105Amp16DHSR14SupportSidePanelReturnAir36DHTS141TerminalStripTB630Amp17DHTX14TEXValve37DHRC141CapacitorCompressor19DHCS14Compressor38DHDF14DefrostSensorwithHarness10i114@@1l3@@@@6391222111

WarrantyFullOneYearPartsWarrantyAllpartsofthedehumidifierarewarrantedtobefreefromdefectsforoneyearfromthedateofpurchasebytheoriginalconsumerwheninstalledpertheinstallationinstructionsandinaccordancewithalllocalstateandnationalcodesfornormalresidentialuselimitedFiveYearCompressorOnlyWarrantyInadditiontothefulloneyearpartswarrantydescribedabovewewillexchangethecompressorduringthesecondyearthroughfifthyearfromtheoriginaldateofpurchaseprovidingthecompressorisdefectiveinmaterialorworkmanshipTransportationhandlingandlaborcoststodiagnoserepairorreplacesuchdefectivepartsarenotcoveredbythislimitedpartswarrantyandaretheownersresponsibilityReadyaccesstotheunitforserviceistheresponsibilityoftheownerNOTElntheeventofanyrequiredpartsreplacementwithintheperiodofthiswarrantyreplacementpartsshallbefurnishedandwillbewarrantedonlyfortheperiodremainingontheoriginalwarrantyExceptionsThewarrantydoesnotcovernormalmaintenancelaborchargestransportationchargesforreplacementpartsreplacementofrefrigerantorfiltersanyotherservicecallorrepairsOtherthanforresidentialuseiftheunitisputintocommercialbusinessrentalorotheruseorapplicationwemakenowarrantiesexpressorimpliedWewillnotbeliablefordamagesordelayscausedbyeventsbeyondourcontrolincludingaccidentalterationabusewargovernmentrestrictionsstrikesfirefloodorotheractsofGodDurationofWarrantyThewarrantybeginsonthedateofpurchasebytheoriginalconsumerTheconsumermustprovideareceiptedbillofsaleasproofofwarrantyperiodWithoutthisproofthewarrantybeginsondateofshipmentfromthefactory1TherearenootherexpressorimpliedwarrantiesoranywarrantyofmerchantabilityWedonotwarrantthattheunitissuitableforanyparticularpurposeorcanbeusedinbuildingsorroomsofanyparticularsizeorconditionexceptasspecificallyprovidedinthisdocumentTherearenootherwarrantiesexpressorimpliedwhichextendbeyondthedescriptioninthisdocument2AllwarrantiesimpliedbylawarelimitedindurationtotheoneyearpartsorfiveyearcompressortermsofthewarrantyYourexclusiveremedyislimitedtothereplacementofdefectivepartsandcompressorWewillnotbeliableforanydamagescausedbyanydefectinthisunitSomestatesdonotallowlimitationonhowlonganimpliedwarrantylastsordonotallowtheexclusionorlimitationofincidentalorconsequentialdamagessotheabovelimitationorexclusionsmaynotapplytoyou3NowarrantiesaremadeforunitssoldoutsidethecontinentalUnitedStatesandCanadaYourdistributororfinalsellermayprovideawarrantyonunitssoldoutsidetheseareasHowtoObtainWarrantyServiceorPartsIfyouhaveawarrantyclaimnotifyyourinstallerpromptlyIfwithinareasonabletimeaftercontactingyourinstallersatisfactoryservicehasnotbeenreceivedcontactCustomerService250WestLaurelStreetColtonCalifornia92324UsAEncloseareportofinspectionbyyourinstallerorservicepersonIncludethemodelnumberserialnumberanddateofpurchaseOwnerresponsibilitiesaresetforthintheinstructionmanualReaditcarefullyrAIRSPONGE250WestLaurelStreetColtonCalifornia92324UsAwwwewfccomTelephone9098250993IIJIUIIIIIIISubjecttoChangewithoutNoticeMarch2007
Other GeneralAire Dehumidifier manuals