GENI SRL-6005 User manual

SRL-6005
PAR LAMP
USER MANUAL

SRL-6005 PAR LAMP
Table of Contents
Introduction-------------------------------------------------------------------------------------------------3
Specification------------------------------------------------------------------------------------------------3
Safety Information----------------------------------------------------------------------------------------3
Installation--------------------------------------------------------------------------------------------------4
Operation---------------------------------------------------------------------------------------------------4
Rear Panel----------------------------------------------------------------------------------------4
Fuse Replacement------------------------------------------------------------------------------4
DMX Mode----------------------------------------------------------------------------------------5
Auto Mode----------------------------------------------------------------------------------------7
2

SRL-6005 PAR LAMP
Introduction
Thank you for purchasing SRL-6005 LED PAR. This product is featured with balanced mix
of RGB LED, and operated via DMX, and AUTO. It will provide you splendid vision
enjoyment.
Specification
Voltage Input:220V/50Hz
Power:50W
LED: 196PCS LED Φ5
Fuse: 2A/250V
Weight:2.8Kg
Size:L136*W202*H209mm
SafetyInformation
Read this manual before powering or installing the fixture. Follow the safety information
listed below and observe all warnings in this manual. If you have any question about how
to operate the fixture safely, please contact the dealer or Neo-Neon after service.
zAlways ground earth electrically. And use only the power supply compliance with
electrical code.
zFor indoor use only. Always keep in dry and ventilated place and away from the rain
and moisture.
zThe unit must be installed in a location with adequate ventilation, at least 50cm from
the flammable objects.
zDo not operate if the ambient temperature exceed 40℃.
zReplace the fuse with the same specified type.
zNo spare parts are available. If needed, please contact the factory.
If any problem, please contact the professionals or the technicians.
3

SRL-6005 PAR LAMP
Installation
SRL-6005 comes equipped with a yoke for hanging installations. The yoke will provide for
a static mount or installation. It is important never to obstruct the fan or vents pathway.
Mount the fixture using the safety hook. Adjust the angle of the fixture by loosening both
knobs and tilting the fixture. After finding the desired position, retighten both knobs.
Never mount in places where the fixture will be exposed to rain, high humidity, extreme
temperature changes or restricted ventilation.
Operation Instruction
Rear Panel
Fuse Replacement
Note: Replace the fuse with the same specified. If not, the potential damage will be
avoided of the company’s responsibility.
Replace the fuse:Disconnect the power, use the screwdriver to unscrew the fuse
holder, take out the fuse, place it with the good one of the same specified
and finally screw the fuse tight.
4

SRL-6005 PAR LAMP
DMX Mode
1. DMX Setting and DMX Value
Operating in a DMX Control mode environment gives the user the greatest
flexibility when it comes to customizing or creating a show. In this mode you will be
able to control each individual trait of the fixture independently.
On Off 1 2 3 4 5 6 7 8 9 10
Switch
1
2
4
8
16
32
64
Value 128
256
2. Plug in the DMX 3-pin XLR signal cable.
3. When the 10th dipswitch is on, PAR Can system enters into DMX Mode.
The other dipswitches 1~9 are for the setting of the DMX channel address.
4. Each Par Can occupies 7 channels: R, G, B. Chief Dimming, Shutter.
For the channel setting, the user must assign a starting address on the fixture that
indicates the first channel reserved in the controller.
5. DMX Address
A. Dipswitch: #1, #2, #3,#4, #5, #6, #7, #8, #9, #10
B. ON=1, OFF=0
C. As the above figure, #1 =ON =1,
the rest #2, #3,#4, #5, #6, #7, #8, #9, OFF=0
The switch does not function, that is ON/OFF does not matter = X
D. Value of Switch #9 =256; Value of Switch #8 = 128; Value of Switch #7 = 64;
Value of Switch #6 = 32; Value of Switch #5 =16; Value of Switch #4 = 8;
Value of Switch #3 = 4; Value of Switch #2 = 2; Value of Switch #1 = 1;
Example
IF Switch #9 =0;Switch #8 = 0;Switch #7 = 0;Switch #6 = 0; Switch #5
=0;Switch #4 = 0;Switch #3 = 1;Switch #2 = 1; Switch #1 = 0; so the Address
Value = 0+2+4+0+0+0+0+0+0=6.
5

SRL-6005 PAR LAMP
E. DMX mode enables the use of a universal DMX controller device. Each
fixture requires a "start address" from 1 to 511. A fixture requiring one or more
channels for control begin to read the data on the channel indicated by the
start address.
There are many different types of DMX controllable fixtures and they all may
vary in the total number of channels required. Choosing a start address should
be planned in advance. Channels should never overlap. If they do, this will
result in erratic operation of the fixtures whose starting address is set
incorrectly.
For example ------Each Par Can occupies 7 channels
If the starting address of the first channel of the first fixture is set to 001, so
The first fixture: 001~007
The second fixture: 008~014
The third fixture: 015~021
The forth fixture: 022~028
The fifth fixture: 029~035
……
6. DMX Connection
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy
Chain connection is where the DATA OUT of one fixture connects to the DATA IN
of the next fixture. The order in which the fixtures are connected is not important
and has no effect on how a controller communicates to each fixture. Use an order
that provides for the easiest and most direct cabling. Connect fixtures using
shielded two conductor twisted pair cable with three pin XLR male to female
connectors.
The shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data
positive (S+).
6. Via Master/Slave, you can set one par lamp to Auto Mode, and others to DMX
Mode. In this way, the master and the slaves run in-sync.
AUTO Mode
When the 10th dipswitch is off, PAR Can system enters into Auto Mode. The system
runs in built-in auto program.
In Auto Mode
Dipswitches: #1, #2, #3, #4, #5, #6, #7, #8, #9
Function: Adjust the Auto-run speed.
6
Table of contents
Other GENI Floodlight manuals
Popular Floodlight manuals by other brands

Chalmit lighting
Chalmit lighting Micronex Installation, operation and maintenance instructions

Elumen8
Elumen8 ELUM042 user manual

SCANGRIP
SCANGRIP FLOOD LITE M manual

Chauvet
Chauvet COLORado Batten 144 user manual

MAXSA
MAXSA 40227 Assembly & operating instructions

Conrad
Conrad 57 50 73 operating instructions