6. Using a 5/16” nut driver or common screw driver, remove the 2 opener cover screws and remove opener cover. FIG-3A
7. Note the locations and disconnect lights, transformer primary, AC power, red & black motor wires, transformer secondary,
and encoder harnesses. FIG. 4
8. Using a 1/4” nut driver or common screwdriver, remove 2 control board mounting screws and remove control board. FIG. 5.
9. Carefully remove all harnesses from harness keepers.
10. Remove Opto Assembly cover screws (3-3/16”) leave harness plugged into assembly FIG. 3B.
11. Install replacement Opto Assembly and install cover screws (3).
12. Carefully slide all harnesses back into harness keepers.
13. Reinstall the control board, harnesses, and opener cover in reverse order. Ensure that harnesses are plugged in the correct
positions. See harness detail FIG. 6.
14. Reinstall BWC & STB wires, light bulb and lens.
15. Install BBU assembly onto motor housing if equipped.
16. Reapply power to operator.
NOTE: Limit settings will require reprogramming. Refer to your owners manual for detailed instructions.
IMPORTANT: Test opener functions. The door MUST reverse on contact with a 1-1/2”high object (or a 2 x 4 board laid at) at the
center of doorway on the oor. After adjusting either the force or limit of travel, retest door opener. Failure to adjust the opener
properly may cause severe injury or death.
PARTS REMOVED FOR CLARITY
Non-BBU Models BBU Models
3-A
3-B
3-A
3-B
39272S Cover Assembly 39272T Cover Assembly
FIG. 3