Attention
The gas cooking range must be installed by
licensed technicians. Otherwise, German Pool will
not be responsible for any damages.
- The inlet gas supply working pressure to the
appliance MUST BE as follows:
Type of gas Inlet pressure
Town Gas1500 Pa
LP Gas 2900 Pa
- Pressure MUST BE ACCURATELY MEASURED
before the appliance is connected.
- If non-compatible pressures are connected to
the appliance, it will affect the performance of
the unit and/or pose risk of damage.
- Prior to installation, ensure that the appliance
is adjustable according to the local distribution
conditions (nature of the gas and gas pressure).
- The adjustment conditions for this appliance
are stated on the label (or data plate).
- This appliance is not connected to evacuation
devices for combustion products. It shall be
installed according to the relevant regulations.
Particular attention shall be given to the
ventilation requirements.
- The use of a gas cooking appliance produces
heat and moisture, so it is essential to ensure
that the kitchen is well ventilated. Keep
natural ventilation windows open or install a
mechanical ventilation device (mechanical
extractor hood). Prolonged intensive use of the
appliance may call for additional ventilation, for
example, opening windows or increasing the
level of mechanical ventilation where present.
- Install the built-in hob in a well ventilated room
and keep it away from any combustible or
in ammable objects such as paper or oil.
- Place the built-in hob on a stable and level
surface.
- If the unit is to be installed close to combustible
surroundings (such as wooden walls, wooden
shelves), it should be installed at least 15 cm
(6”) from the side walls. The unit should be
installed with a distance of at least 15 cm away
from surrounding combustible materials.
- Distance from bottom should be at least
50 mm (2”).
- This appliance does not need to be installed
with an external gas governor.
P.7
距離底部不少於50mm (2英吋)。
P.6