Gespasa GK-7PLUS User manual

03.2014
GK-7PLUS
CONSUMPTION CONTROLLER
SUPERVISOR AND USER MODE
INSTRUCTION MANUAL
Unit 7 Swan Business Centre
Osier Way, Buckingham
MK18 1TB
Email: [email protected]
https://www.bellflowsystems.co.uk
+44 (0) 1280 817304

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
2

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
3
CONTENT
1. GENERAL INSTRUCTIONS TO USE THE KEYPAD ....................................................5
2. USER MODE...........................................................................................................6
Step 1. User identification........................................................................................6
Step 2. Vehicle identification ....................................................................................7
Step 3. Vehicle mileage introduction..........................................................................7
Step 4. Predetermination introduction .......................................................................8
Step 5. Supply starting............................................................................................8
Step 6. Supply end.................................................................................................8
Step 7. Supply ticket...............................................................................................9
3. SUPERVISOR MODE ............................................................................................10
3.1. SUPERVISOR mode access ..............................................................................10
3.2. SUPERVISOR mode menu................................................................................10
3.2.1. SUPERVISOR mode / IDENTIFIERS........................................................................10
3.2.2. SUPERVISOR mode / REGULARIZATION.................................................................11
3.2.3. SUPERVISOR mode / CALIBRATION.......................................................................11
3.2.4. Supervisor Mode / CONFIGURATION LIST............................................................... 12
3.2.5. SUPERVISOR mode / SUPERVISOR MENU............................................................... 12
3.2.5.1. SUPERVISOR Mode / SUPERVISOR Menu / CONFIGURATION..........................14
3.2.5.1.1. SUPERVISOR mode / SUPERVISOR MENU / CONFIGURATION / CONSOLE .........14
3.2.5.1.2. SUPERVISOR mode / SUPERVISOR MENU / CONFIGURATION / TANKS .............15
3.2.5.1.3. SUPERVISOR mode / SUPERVISOR MENU / CONFIGURATION / HOSES.............15
3.2.5.1.4 Supervisor Mode / SUPERVISOR MENU / CONFIGURATION / GPRS (only in
kits with GPRS connection) ........................................................................................16
3.2.5.1.5 Supervisor Mode Supervisor / SUPERVISOR MENU / CONFIGURATION /
ETHERNET (only in kits with ETHERNET connection)......................................................17
3.2.5.2. SUPERVISOR mode / SUPERVISOR MENU / DATE/HOUR................................17
3.2.5.3. SUPERVISOR mode / TECHNICAL MENU / INITIALIZATION............................18
3.2.6. GPRS (only in kits with GPRS connection)...............................................................18
4. THE PRINTER......................................................................................................19
Appendix A · Factory controller configuration.........................................................20
Appendix B. Insert or replace the SIM card of the GK-7PLUS controller (only in
kits with GPRS connection) ....................................................................................21
CONFORMITY DECLARATION ..................................................................................23

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
4
ATTENTION
The GK-7PLUS controllers belong to the GK-7 family controllers and are designed to
automatically communicate M2M with the DieselPlus application.
The GK-7PLUS controllers are not able to work in autonomous way; they need the DieselPlus
application in order to both manage the stored users and vehicles and control their supplies
and stocks.

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
5
1. GENERAL INSTRUCTIONS TO USE THE KEYPAD
The kit has a keypad of 14 keys distributed as it is shown below:
In general the numeric keys will be used for the access and data code typing, both in user and supervisor
mode.
When the kit is waiting for the value typing, where it is possible a value with a decimal, you have to press
the key <▼> as a decimal.
During the data typing, you have to use the key <▲> to delete the last typed character.
The key <OK> will be used to confirm the typed data or the selected options.
In supervisor mode, the keys <▲> and <▼> will be used to select one of the different options shown in the
menus.
The <EXIT> key will be used to cancel the action that is being carried out or the current menu, and to go
back to the last display.
Identification key
Identification key reader

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
6
2. USER MODE
The user mode is the mode that the kit allows making a supply to an authorized user.
Depending on the kit configuration, it will be necessary to make some or every one of the following steps so
that a supply is completed:
Step 1. User identification
According to the kit configuration, this step is made through the following options:
Identification by key:
- If the kit has been configured for
user identification by key, the display
will show the following message as
well as the date and the hour:
PASS IDENTIFIER
The user must put the identification
key in its place and keep it in this
position until the kit recognizes it,
making a brief 'beep'.
- If the identifier is not one of the
authorized identifiers, the kit will show
the following message during some
seconds: IDENTIFIER
NOT VALID
and after this time it will go back to
the initial display.
- If, on the contrary, the identifier is
known as an authorized identifier, the
kit will show the following message:
TYPE PERSONAL CODE:
The user must type its PIN or personal
code, composed of 4 digits, and
confirm with the key <OK>.
If the typed code is not correct, the kit
will ask for the code typing again. If
the user types an incorrect code three
times, the user will have to pass again
the identifier.
If the identification has been correct,
the kit will
p
ass to the followin
g
ste
p
.
Identification by PIN:
- If the kit has been configured for
user identification by PIN code, the
display will show the following
message as well as the date and the
hour:
PRESS A KEY
- Pressing any key, it will appear the
following message on the display:
TYPE PERSONAL CODE:
The user must type its PIN or personal
code, composed of 4 digits, and
confirm with the key <OK>.
If the typed code is not correct, the kit
will ask for the code typing again. If
the user types an incorrect code three
times, the user will have to pass again
the identifier.
If the identification has been correct,
the kit will pass to the following step.
Without user identification
- If the kit is configured to work
without user identification, this step
will not be made. The position starting
of the kit will be that described in the
step 2.

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
7
Step 2. Vehicle identification
According to the kit configuration, this step is made through the following options:
Step 3. Vehicle mileage introduction
If the identified vehicle has activated the consumption control, the kit will show the following message:
TYPE
KILOMETRES:
or the message:
TYPE
HOURS:
as it is defined the vehicle when it is entered.
The user must type the value that the odometer or the vehicle hour counter has when the service is made.
Once the value is typed, the user must confirm it with the key <OK>.
Identification by key:
- If the kit has been configured for
vehicle identification by key, this will
start with the following message in the
display:
PASS IDENTIFIER
- The user must put the identification
key of the vehicle in its place and keep
it in this position until the kit
recognizes it, making a brief 'beep'.
If the identifier is not one of the
authorized identifiers, the kit will show
the following message during some
seconds: IDENTIFIER
NOT VALID
and after this time the kit will ask for
the identifier again.
This can be repeated up to three
times, and then the kit will reinitiate
the service authorization process.
If the identification has been correct,
the kit will pass to the following step.
Identification by numerical code:
- If the kit has been configured for
vehicle identification by numerical code,
the display will show the following
message:
TYPE THE VEHICLE
CODE:
- The user must type the vehicle code.
This code is composed of any
combination from 1 to 5 digits, and it is
confirmed with the key <OK>.
If the typed code is not correct, the kit
will ask for the code typing once again.
If the user types an incorrect code
three times, the user will have to pass
again the identifier.
If the identification has been correct,
the kit will pass to the following step.
Without vehicle identification
:
- If the kit is configured to work
without vehicle identification, this step
will not be made.
Identification by vehicle assignment
:
- If the user identified in the Step 1
has an assigned vehicle, this step will
not be made. The vehicle that the user
has assigned will be identified in the
service authorization.

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
8
Step 4. Predetermination introduction
Depending on the kit configuration, it is possible to be asked to preset the fuel quantity that you want to
supply. In this case, the display will show the following message:
TYPE AMOUNT
PRESET:
If the user really wants to preset a volume, he will have to type the quantity, and confirm it with the key
<OK>.
It is possible to type a value of litre fraction or the volume unit which you are working with, typing the
decimal with the key <▼>. If the user does not want to preset the supply volume, he will have to press the
key <OK>.
It is important to point out the accuracy of the supplied volume will depend on the installation of the required
valves to reduce or cut the flow in the right moment.
Step 5. Supply starting
At this moment, the display will show the following message:
SERVICE
AUTHORIZED
The user has to take the nozzle off. Then, the pump motor will start, and the display will change showing
the supply volume through big size numerical digits.
The shown quantity resolution, in tenth or hundredth of litres, or the volume unit which is working with, will
depend on the kit configuration.
Step 6. Supply end
The supply finishes with the pump motor stop, and this can happen because of any of the following causes
(the first that happens):
-The user hangs up the nozzle.
-It has passed some time without passing liquid equal to that configured in the parameter 'seconds
without pulses‘.
-The supply has achieved the configured volume in the parameter 'maximum amount'.
-The supply has taken an equal time than that configured in the parameter 'maximum time'.
The display will show the value reached in the supply during the next 60 seconds after the supply end. After
this time, the kit will return to the start situation of the service authorization.

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
9
If it is necessary to start a new identification before the described time passes, the user will have to pass
the identifier or press a key, depending on the configured identification mode.
Step 7. Supply ticket
If the kit is connected to a ticket printer, it is possible to print a supply ticket similar to the model shown
below.
The way to print this ticket depends on the value of the parameter 'ticket edition' in the definition of the user
that has made the service.
If it is defined as ‘Yes’, the user will not have to make any action, and the kit will automatically print the
ticket.
If it is defined ‘by request’, the user will be able to choose to print or not to print the ticket.
- If he wants to print the ticket, he will have a determined time to pass again the identification key or
type his PIN code, depending on the identification mode, and ask for the ticket printing.
The value, in seconds, of this time is that configured in the parameter ‘ticket request seconds’.
If the user lets this time pass and he is identified again, the kit will understand that he wants to start a
new identification.
Finally, if the user is defined with the parameter ‘ticket edition' as 'No', the user will not be able to print
the ticket.
COMPANY NAME
Address
Town
NIF
07/05/2013 11:09:55
NUMBER: 5564
USER: 345
VEHICLE: 233
KILOMETRES: 122334
PRODUCT: DIESEL A
QUANTITY: 34.02
PRICE: 0,850
TOTAL: 28.92
THANK YOU VERY MUCH
This shown ticket model is the complete ticket. The edited data will depend on the system configuration.
So, i.e., the first and last lines are free texts; the kilometre line will or will not be shown depending on
whether the vehicle has or has not activated the consumption control; or the lines related with the amount
will be only shown if the price per litre or the volume unit with which is working has a different value of zero.

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
10
3. SUPERVISOR MODE
The Supervisor mode is the mode where the kit allows the authorized person (from now on, SUPERVISOR)
to make all the configuration system operations, as well as to get the stored data.
According to the kit configuration, this mode can show the different menus and options that will be
described in this manual.
3.1. SUPERVISOR mode access
The SUPERVISOR is identified as any other user. If the system is configured for user identification through
identification key + PIN, there will be a key that the kit will identify as the SUPERVISOR that, along with the
associated PIN, will give access to this mode. Otherwise, if the kit is configured for the user identification
through PIN, there will be a PIN associated to the SUPERVISOR.
3.2. SUPERVISOR mode menu
To go into the SUPERVISOR mode, first you have to press the key <OK> without dropping it, press the key
<▼> at the same time. Once the SUPERVISOR (PIN 0220) is correctly identified, the display will show the
following menu:
SUPERVISOR MODE
> IDENTIFIERS
REGULARIZATION
CALIBRATION
CONFIGURATION LIST
SUPERVISOR MENU
GPRS (only with the kits with GPRS connection)
The desired option will be chosen pressing the keys <▲> and <▼> until the pointer > points to the option.
Then press the key <OK>.
The different options are described below:
3.2.1. SUPERVISOR mode / IDENTIFIERS
This option allows the code reading that an identifier has. Once selected, the display shows the following
message:
PASS IDENTIFIER
The kit will wait the user places the identifier on its site. If the identifier is usable, the kit will read its code,
and it will show it in the last line of the display.
Pressing the key <EXIT>, it will be shown again the SUPERVISOR MODE menu.

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
11
3.2.2. SUPERVISOR mode / REGULARIZATION
This option allows adjusting the level shown by the kit to the real level that there is in the tank. Because of
some differences in the accuracy of some instruments, which are used to count the entered and supplied
liquid, it is possible that there can be some imbalances between the shown value by the kit and the
measured value. This option allows making a "regularization" of this level.
Once selected one of the available tanks, the display will show:
REGULARIZ. LIQUID X
CURRENT QUANTITY:
The kit will wait that the current litre (or the volume unit with which is working) number is typed. Once the
quantity is typed and confirmed with the key <OK>, the kit will have this value as the current tank level.
3.2.3. SUPERVISOR mode / CALIBRATION
This option allows the meter calibration. The kit has built in an automatic electronic calibration process by
means of passing a known amount of liquid through the meter; while the kit "counts" the pulses generated
by the meter. Once the liquid has passed, it will be indicated to the kit the transferred amount with which the
kit can calculate the relation that there is between the pulses and the volume. Independently of this system,
the kit has also built in the traditional system of the whole factor, as it will be described below.
Procedure: Accepting the CALIBRATION option, after putting the pointer and pressing the key <OK>, the kit
will start the pump (independently of the nozzle position) and will show the following message on the
display:
SUPPLY KNOWN AMOUNT
AND PRESS OK
In this point, fill a recipient with a known volume. The best option is to use a homologated dekalitre. Once
filled, press <OK>, and the kit will stop the pump and show the following message:
TYPE SUPPLIED
AMOUNT:
where the supplied volume must be typed. Remember that there is the possibility to type in decimals.
Consult the section 1. General Instructions to use the keypad.
Once typed this amount and confirmed with the key <OK>, the display will show the following message:
NEW FACTOR FFFFFF
OK = ACCEPT
EXIT = REJECT
where FFFFFF is the new calculated factor of calibration and represents the number of hundred thousandth
of litres (or the volume unit with which is working) that the count will be increased by each received pulse,
having the option to accept the new value through the key <OK> or reject it through the key <EXIT>.
If the kit has not noticed any pulse or the typed quantity has been equal to 0, it will not be possible to make
the calculation and the shown message will be:

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
12
CALIBRATION PROCESS
ERROR
OK = ACCEPT
Pressing <OK> you will come back to the display of the SUPERVISOR MODE and the calibration factor will
not be modified.
If the new factor has been calculated, once accepted, the display will show the following message:
PROTECT FACTOR?
OK = YES
EXIT = NO
With the affirmative answer, it is achieved the new factor is not altered by a value that can get from a
possible communication of the control software installed in a computer. So the factor value "is protected". If,
on the contrary, it is answered in negative, the factor will be modified by the received communication of the
software. This protection only affects to the described case. It is not valid when a recalibration is made from
the controller.
It is possible to cancel the calibration process pressing the key <EXIT> at any moment. The display will
return to the SUPERVISOR MODE.
3.2.4. Supervisor Mode / CONFIGURATION LIST
This option shows the current kit configuration. A parameter of this configuration, which exactly shows
whether a printer is or is not enabled in the system, will point out where the list will be displayed. If the
printer is enabled, the list will be printed. If, on the contrary, it is not enabled, the configuration will be only
shown on the display.
The system configuration is divided into Console Configuration, Product Configuration, Tank Configuration,
and Hose Configuration, containing each one of these divisions some configuration parameters.
This option does not allow modifying these parameters; these can be only displayed. In the following
section of the SUPERVISOR MODE, SUPERVISOR MENU, each and every one of these parameters can
be modified and explained.
3.2.5. SUPERVISOR mode / SUPERVISOR MENU
This SUPERVISOR MODE section is that really allows the system data contribution and recovery.
This option is not always visible. If the kit is controlled from a computer, this menu will not be accessible to
avoid the possibility of typing data to the system from two different sources, the computer program, and the
own kit keypad. In this case, in this menu position, it will appear the PC DISCONNECTION option. Selecting
it and accepting it, it will appear again the SUPERVISOR MENU.
This menu has the following structure:
SUPERVISOR MENU
CONFIGURATION
CONSOLES
USER IDENTIF.
VEHICLE IDENTIF.
PREDETERMINATION

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
13
SUPERVISOR ID.
SUPERVISOR PIN
LCM HEADING
LANGUAGE
PRINTER LINE 1
PRINTER LINE 2
PRINTER LINE 3
PRINTER LINE 4
PRINTER LINE 5
TICKET REQUEST SECONDS
ADDRESS
HIDING 300 ml
TAX DECIMALS
PRICE DECIMALS
TOTAL DECIMALS
HOSE SELECTOR
TANKS
NAME
SALE PRICE
TAX
HOSES
GENERATOR TYPE
RESOLUTION
FACTOR
FACTOR PROTECTION
TANK
W/O PULSES
MAXIMUM AMOUNT
MAXIMUM TIME
GPRS
OPERATOR
USER
PASSWORD
SERVER
LOCAL PORT
REMOTE PORT
ETHERNET
IP ADDRESS
NET MASK
GATEWAY
SERVER
LOCAL PORT
REMOTE PORT
DNS1
DNS2
DATE/HOUR
STARTING

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
14
3.2.5.1. SUPERVISOR Mode / SUPERVISOR Menu / CONFIGURATION
Once into configuration, the display will show the following menu:
> CONSOLE
TANKS
HOSES
GPRS (only in kits with GPRS connection)
ETHERNET (only in kits with ETHERNET connection)
3.2.5.1.1. SUPERVISOR mode / SUPERVISOR MENU / CONFIGURATION / CONSOLE
This part of the configuration allows modifying the parameters that refer to the console operation. These
parameters are:
USER IDENTIFICATION: It shows the way the users will be identified. The available options are:
- Without identification: where the system will only identify the vehicle not the user.
- By PIN: the PIN (Personal Identification Number) is a code of four digits.
- By identification key + PIN: where each user has assigned an identification key plus a code of four
digits.
VEHICLE IDENTIFICATION: It shows the way the vehicles will be identified. The available options are:
- Without identification: where the system will only identify the user not the vehicle.
- By identification key: where each vehicle has assigned an identification key.
- By numeric code: where each vehicle has assigned a numeric code among 1 and 99 999.
PREDETERMINATION: This parameter allows or not enabling the predetermination (preset) in the
supplies. For more information consult the section Predetermination Introduction of the USER MODE.
SUPERVISOR ID.: It is the identifier code of the SUPERVISOR as long as the system is configured for
the user identification by identification key + PIN. If not, it is irrelevant.
SUPERVISOR PIN: It is the PIN code associated to the SUPERVISOR.
LCM HEADING: It is a text of 20 characters, freely editable, that will appear in the first line of the display
while the kit is in the waiting state.
LANGUAGE: Select the language.
PRINTER: It specifies if the printer is or is not enabled.
PRINTER LINE 1: It is a text of up to 32 characters, freely editable, that will appear in the first line of the
ticket.
PRINTER LINE 2: It is a text of up to 32 characters, freely editable, that will appear in the second line of
the ticket.
PRINTER LINE 3: It is text of up to 32 characters, freely editable, that will appear in the third line of the
ticket.
PRINTER LINE 4: It is text of up to 32 characters, freely editable, that will appear in the fourth line of the
ticket.

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
15
PRINTER LINE 5: It is text of up to 32 characters, freely editable, that will appear in the last line of the
ticket, after all the supply data. This text will be shown in a centred position respect to the paper width.
TICKET REQUEST SECONDS: It is the time in seconds that a user has to identify himself again, after
finishing the supply, to obtain the ticket if that user has defined the parameter of ticket edition by request.
ADDRESS: It is a number among 1 and 15 that represents the address of that console into a possible
console network connected to the same port of a computer. In this network, each one of the consoles
must have an own address that do not have any other of the other consoles.
HIDING 300 ml: The display does not show the first supplied 300 ml.
TAX DECIMALS: It allows entering up to 4 decimals.
PRICE DECIMALS: It allows entering up to 4 decimals.
TOTAL DECIMALS: It allows entering up to 4 decimals.
HOSE SELECTOR: It must be always selected the NO option, even though there are connected 2
hoses.
3.2.5.1.2. SUPERVISOR mode / SUPERVISOR MENU / CONFIGURATION / TANKS
This part of the configuration allows modifying the parameters that refer to the tanks that have the products
that the installation can supply. These parameters are:
NAME: It is the product name. This name will appear in the ticket at the end of the supply if it has a
printer.
SALE PRICE: It is the price per litre (or the volume unit with which it is working) of the product. The kit
will print a valued ticket if this parameter is different from 0. Otherwise, the produced ticket will not have
any reference to the transaction amount.
TAX: It is the percentage applied to the total amount of the transaction, understood as supplied litres (or
the volume unit with which it is working) multiplying the Sale Price, in concept of Taxes.
3.2.5.1.3. SUPERVISOR mode / SUPERVISOR MENU / CONFIGURATION / HOSES
This part of the configuration allows modifying the parameters that refer to the hoses controlled by this
console. These parameters are:
GENERATOR TYPE: It allows selecting the type of pulse generator for that hose. It is possible to select
among:
- generators of 2 180º phase-out channels
- generators of 2 90º phase-out channels
- generators of 1 channel
RESOLUTION: It is the resolution with which the supplied volume, through this hose, must be shown, in
the kit display. It is possible to select a resolution of tenth of litre or hundredth of litre (or the volume unit
with which is working).
FACTOR: It represents the resolution of the system composed of the meter set plus the pulser.

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
16
The value of this parameter can be calculated in the following way:
Factor = 100 000 / (meter turns per litre * pulses of the generator per turn)
This factor will be divided by two in the event that the type of selected generator has two 180º phase-out
channels.
Remember that the kit allows an automatic calibration that avoids making the calculation of this factor,
as it is described in the section SUPERVISOR MODE / CALIBRATION.
FACTOR PROTECTION: If this option is activated, the stored factor in the kit will not be altered by the
parameters passed through the communication from the control software. It is an option to take into
account in the hydraulic systems where it is not possible to calculate a whole fix factor and where the
calibration must be done in an automatic way. Please consult the SUPERVISOR MODE /
CALIBRATION for more details.
TANK: It is the number of the tank from which that hose is supplying liquid.
SECONDS W/O PULSES: It is the time, in seconds, during which the kit will have an active supply
without a liquid pass. Once this time passes, the kit will finish the service.
MAXIMUM QUANTITY: It is the maximum volume, in litres (or the volume unit with which is working),
that the kit will allow supplying in one go. Once this amount is achieved, the kit will finish the service.
MAXIMUM TIME: It is the maximum time, in seconds, that the kit will have active a supply. Once this
time passes, the kit will finish the service.
3.2.5.1.4 Supervisor Mode / SUPERVISOR MENU / CONFIGURATION / GPRS (only in kits with
GPRS connection)
This option allows the parameter configuration so that the GPRS connection and the later synchronization
of information with the DieselPlus application are established.
OPERATOR: Name of the access point (APN) given by the operator of the mobile network of the
installed SIM card.
USER: User of the GPRS connection given by the operator of the mobile network of the installed SIM
card.
PASSWORD: User password of the GPRS connection given by the operator of the mobile network of
the installed SIM card.
SERVER: Domain or IP address of DieselPlus used for the communications with the GK-7PLUS
controller given by DieselPlus.
LOCAL PORT: Listening port number of the GK-7PLUS given by DieselPlus.
REMOTE PORT: Listening port number of the DieselPlus application given by DieselPlus.
The values of the SERVER, LOCAL AND REMOTE PORT only can be modified from the DieselPlus
application.

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
17
3.2.5.1.5 Supervisor Mode Supervisor / SUPERVISOR MENU / CONFIGURATION / ETHERNET
(only in kits with ETHERNET connection)
This option allows the parameter configuration that take part in the ETHERNET connection and the later
communication of information with the DieselPlus application.
IP ADDRESS: IP address assigned to the GK-7PLUS controller in the local network given by the
network administrator.
NETMASK: It determines the local network scope given by the network administrator.
GATEWAY: IP address of the link gate given by the network administrator.
SERVER: Domain or IP address of DieselPlus used for the communications with the GK-7PLUS
controller given by DieselPlus.
LOCAL PORT: Listening port number of the GK-7PLUS given by DieselPlus.
REMOTE PORT: Listening port number of the DieselPlus application given by DieselPlus.
DNS1: Preferred DNS Server.
DNS2: Alternative DNS Server
The values of the SERVER, LOCAL AND REMOTE PORT only can be modified from the DieselPlus
application.
3.2.5.2. SUPERVISOR mode / SUPERVISOR MENU / DATE/HOUR
This option allows adjusting the clock of real time that the kit has. Selecting it, the display shows:
DATE
CURRENT 08/04/2013
NEW / /
In this point, type the correct date and then <OK>. The used format is DDMMYYYY. If the shown date is
correct, it is possible to keep it pressing the key <OK> directly. If it is typed an incorrect date, the system will
not modify the current date although it will not inform about this fact.
Once completed the date regularization, the kit will show the following message:
HOUR
CURRENT 13:06:43
NEW : :
In this point the correct hour will be typed followed by the key <OK>. The used format is HHMMSS. If the
shown hour is correct, it is possible to keep it pressing the key <OK> directly. If it is typed an incorrect hour,
the system will not modify the current hour although it will not inform about this fact.

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
18
3.2.5.3. SUPERVISOR mode / TECHNICAL MENU / INITIALIZATION
Through this option it is possible to initialize the different data files of the system or what it is the same to
eliminate the information that the kit has. Please act with extreme caution in this option as it is not
possible to recover this information once some of the files are initialized,.
Once this option selected, it will appear a menu with the following options:
USER FILE
VEHICLE FILE
SERVICE FILE
CONFIGURATION FILE
ALL
Selecting any of them, the kit will show the following message:
CONFIRM
INITIALIZATION
Confirm with the key <OK> to make effectively the operation or press any other key to exit.
The effect of making an initialization on each one of these files is the following:
USERS: All the authorized users will be eliminated.
VEHICLES: All the authorized vehicles will be eliminated.
SERVICES: All the stored services will be eliminated.
CONFIGURATION: It will be loaded a system configuration by defect. This configuration can be consulted
in the APPENDIX A.
Selecting the option ALL, it will be made an initialization of each and every one of the four files.
3.2.6. GPRS (only in kits with GPRS connection)
Through this option, it is possible to consult the GPRS connection and it is not allowed to be modified. to
configure the parameters linked to the GPRS connection, access the options into 3.2.5.1.4. SUPERVISOR
MODE / SUPERVISOR MENU / CONFIGURATION / GPRS).
STEPGPRS: Number that determines the GPRS connection state
OPERATOR: It informs about the user configured in the GPRS controller parameters.
COVERAGE: GPRS signal in the mobile phone network. Its range is among 0 (without signal) and 31
(maximum signal).
IP: IP address assigned by the mobile phone operator.

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
19
4. THE PRINTER
The controller is equipped with a thermal printer of 32 columns with an automatic built-in cut, in order to
print tickets and lists.
The adequate paper for this type of printers is thermal paper with a width between 56 and 57 mm. It is
advisable to use paper of quality to obtain a good printing and prevent damages to the printer mechanical
system.
HOW TO REPLACE THE PAPER ROLL BY A NEW ONE:
1- Open the upper door that covers the printing system.
2- Raise the cutter. This turns by its upper shaft.
3- Remove the finished roll and put the new one.
4- Put the beginning of the new roll by the lower printer groove. You have to make a clean and
perpendicular cut on the paper.
5- The printer has an automatic charging system that will pick up the paper when its sensor detects it.
Leave that the mechanical system freely takes the paper.
6- If it is necessary to take over the paper because it is not correctly entering, it is possible to raise the
printing heading through a lever that is placed on the printer left. Once this lever is liberated, it is possible to
move the paper to be centred. As soon as the lever is down, the printer will pick up some centimetres of
paper.
7- Pass the paper through the groove of the cutter.
8- Finally, close de door.

GK-7PLUS CONTROLLER INSTRUCTION MANUAL
20
Appendix A · Factory controller configuration
The configuration by defect is that the kit has (approx.) when it goes out from the factory or after an
initialization. This configuration is the following one:
CONSOLE CONFIGURATION:
User identification: PIN
Vehicle identification: Numeric code
Predetermination: Not enabled
Supervisor identify.: 000000000000
PIN Supervisor: 0220
Product number: 1
Tank number: 1
Hose number: 1
LCD heading: GK-7 CONTROLLER
Language: Spanish
Printer: Not enabled
L1 Printer: GK-7 CONTROLLER
L2 Printer:
L3 Printer:
L4 Printer:
L5 Printer:
Ticket requ. Seconds: 60
Address: 1
Hiding 300 ml YES
TAX decimals 0
Price decimals 3
Total decimals 2
Hose selector NO
Free field UNABLED
Free field mask NUMERICAL
Free field Text1
Free field Text2
TANK 1
Product PRODUCT 1
PRODUCT 1:
Name: PRODUCT
Sale price: 0.000
Tax: 0
HOSE CONFIGURATION
HOSE 1
Tank: 1
Resolution: 1/100
Generator type: 2 channels at 9º
Divisor Factor: approx. 500(1)
Factor Protection: Not protected
Seconds w/o pulses: 90
Maximum amount: 1000
Maximum time: 600
(1) This value can be changed depending on its calibration from factory.
Table of contents
Popular Controllers manuals by other brands

Automation Devices
Automation Devices 6006 Series Adjustments and Set Up

Panasonic
Panasonic WV-CU101 operating instructions

Seneca
Seneca Z-LTE Series installation manual

Vortex
Vortex iStat6 user manual

ANALOGUE SYSTEMS
ANALOGUE SYSTEMS RS200 manual

Rockwell Automation
Rockwell Automation micrologix 1200 installation instructions