FunctionMonitoring terminalsOutputMin.breaking capacity DCSwitching voltageCurrent ratingRated supply frequencyMeasurement errorMeasuring range DimensionsWeightStandardsMechanical lifeElectrical life(AC1)Voltage range(Un)Operating temperatureStorage temperatureMounting/DIN railProtection degreeOperating positionOvervoltage cathegoryPollution degree
Time deviation
Temperature coefficient L1-L2-L32×SPDT8A/AC1250VAC/24VDC500mWMonitoring 3-phase voltage GRV8-SN≤1%≤5%127-132-138-220-230-240-254-265(P-N)127-132-138-220-230-240-254-265(P-N)
130V-650V
solid wire max.1×2.5or 2×1.5/with sleeve max.1×2.5(AWG 12)
90×36×64mm 109g 100gEN 60255-1,IEC60947-5-1
1×10L1-L2-L3-N
70V-400V
45Hz-65Hz1×105GRV8-SP220-230-240-380-400-415-440-460(P-P)220-230-240-380-400-415-440-460(P-P)-20℃ to +55℃(-4℉ to 131℉)-35℃ to +75℃(-22℉ to 158℉)Din rail EN/IEC 60715IP40 for front panel/IP20 terminalsany
-1-
General■Model and connotationTechnical parametersInstruction Manual3-Phase display voltage relay GRV8-SGEYA ELECTRICAL CO.,LTDAdd:Wenzhou Brige Industrial Zone,Beibaixiang Town,Yueqing,Zhejiang,China 325603■Applications -Control for connection of moving equipment(site equipment,agricultural equipent,refrigerated trucks). -Control for protection of persons and equipment against the consequences of reverse running. -Normal/emergency power supply switching. -Protection against the risk of a driving load(phase failure).■Function Features -Controls its own supply voltage(True RMS measurement). -LCD display. - Measuring frequency range:45Hz-65Hz. - Voltage measurement accuracy<1%. - 2-MODULE,DIN rail mounting. GRV8 SeriesGRV8 N:phase to neutralP:phase to phaseS LCD display Rated control supply code:Wiring DiagramL1L2L3121114~U222124Short press T/R 0.5s can test relay action.Operation description0.5s 11(21) 12(22) 14(24) 11(21) 12(22) 14(24)NOTE:Only when the power supply is normal, press the button.Phase voltage inquiryShort press to see the value of 3- phase voltage.212224L1L2L3N~UGRV8-SPGRV8-SNGRV8-SPGRV8-SNAuto-resetParameter setting rangeAsy=Note:Uavr=Umax=Max(U1,U2,U3)Umin=Min(U1,U2,U3)Umax-UminU1+U2+U3Uavr3×100%Rate voltage(Un)220VGRV8-SNGRV8-SP380VOFF,(Un+1)...350OFF,(Un+1)...60080...(Un-1),OFF150...(Un-1),OFF0.05%/℃,at=20℃(0.05%℉,at=68℉)NHysteresis
2%
Phase failure value50% of Un selected
0.4Nm
Tightening torqueTel:0086-577-62771036Fax:0086-577-62711079E-mail:sale@cnyeya.comWeb:www.geya.net
-2-
Functions DiagramDimensions(mm)
http://www.geya.net
Disposal of Electrical WasteAll electrical waste should bedisposed of in compliance withcurrent WEEE regulations.
95
4.2R/TMDMDRGRV8-S
121411222421
7036max
L1L2L3N
●Phase failure and phase equence function diagram
141112L3
TrTrTrTr
L2L2L1L3L1L3L2L2L1L3L1242122
●Overvoltage and undervoltage function diagram
ToTu<Tu<ToTrTrTr
L1/L2/L3L1/L2/L3-N
212422
●Asymmetry function diagram
Tr:Power up delay
Ta<TaTr
212422
Parameter setting Start and reset time setting Automatic reset setting
Voltage asymmetry action time setting
GRV8-SNPress MD 3s to enter the param-eter setting interface.Overvoltage settingOvervoltage action time settingUndervoltage settingUndervoltage action time setting GRV8-SP GRV8-SP GRV8-SNPhase sequence settingVoltage asymmetry settingNOTE:Short press can add and drop parameters, long press can be quickly set.If 60s does not operate the key, it will exit automatically.When over-voltage protection, und-ervoltage protection or unbalanced protection are switch-ed off,The menu is not showing the action time setup process.Rated voltage setting GRV8-SN
GRV8-SP GRV8-SN
CautionThe products must be installed by qualified electricians. All andany electrical connections of the product shall comply withthe appropriate safety standards.

This manual suits for next models

1

Other GEYA Relay manuals

GEYA GRT8-D User manual

GEYA

GEYA GRT8-D User manual

GEYA GRT8-P User manual

GEYA

GEYA GRT8-P User manual

GEYA GRT8-RL User manual

GEYA

GEYA GRT8-RL User manual

GEYA GRT8-WS User manual

GEYA

GEYA GRT8-WS User manual

GEYA GRT8-X1 User manual

GEYA

GEYA GRT8-X1 User manual

GEYA GRT8-TS Series User manual

GEYA

GEYA GRT8-TS Series User manual

GEYA GRT8-S1 User manual

GEYA

GEYA GRT8-S1 User manual

GEYA GRT6-S Series User manual

GEYA

GEYA GRT6-S Series User manual

Popular Relay manuals by other brands

Pilz PZE X5 operating manual

Pilz

Pilz PZE X5 operating manual

Woodward MRG3 manual

Woodward

Woodward MRG3 manual

Siemens 3VU2932-4 Series Assembly instructions

Siemens

Siemens 3VU2932-4 Series Assembly instructions

Pilz PNOZ s3 operating manual

Pilz

Pilz PNOZ s3 operating manual

Pilz PNOZ e3vp 10 operating instructions

Pilz

Pilz PNOZ e3vp 10 operating instructions

Projecta VSR100 quick guide

Projecta

Projecta VSR100 quick guide

Honeywell TRADELINE R8184G quick start guide

Honeywell

Honeywell TRADELINE R8184G quick start guide

ABB REJ 521 Operator's manual

ABB

ABB REJ 521 Operator's manual

Siemens 3RB12 instructions

Siemens

Siemens 3RB12 instructions

F&F FW-R2D manual

F&F

F&F FW-R2D manual

YewdaleDefiant 980014 Programming instructions

YewdaleDefiant

YewdaleDefiant 980014 Programming instructions

Aiphone RY-18L instructions

Aiphone

Aiphone RY-18L instructions

ABB CIRCUIT SHIELD 437W Series instructions

ABB

ABB CIRCUIT SHIELD 437W Series instructions

GE P642 Technical manual

GE

GE P642 Technical manual

Vimar Elvox 0170/101 Installer's guide

Vimar

Vimar Elvox 0170/101 Installer's guide

Pepperl+Fuchs KFD2-RSH-1.2D.FL2 Original instructions

Pepperl+Fuchs

Pepperl+Fuchs KFD2-RSH-1.2D.FL2 Original instructions

FANOX SIL-G user manual

FANOX

FANOX SIL-G user manual

CD Automation 1100A user manual

CD Automation

CD Automation 1100A user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.