GEYA GRT8-X1 User manual

-1-
Wiring diagramInstruction ManualDigital display time relayGEYA ELECTRICAL CO.,LTDAdd:Wenzhou Brige Industrial Zone,Beibaixiang Town,Yueqing,Zhejiang,China 325603Tel:0086-577-62711079Fax:0086-577-62711751Mobile:0086-13567770207E-mail:sale@cnyeya.comWeb:www.geya.netGeneral■Applications -Multifunctional time relay can be used for industrial equipment, lighting control, heating element control, motor, fan control. -With 20 delay modes, the delay range covers 0.1 seconds to 99 days.■Function Features -20 delay modes: -5 delay modes controlled by power supply -13 delay modes controlled by signal -ON, OFF mode -Ultra wide delay range, 0.1 seconds - 99 days can be set. - Relay status is indicated by LED. - 1-MODULE,DIN rail mounting. ■Model and connotationPanel DiagramTechnical parametersGRT8-X1Digital displayUnUnDigital Setting Time RelayNumber of contacts1:1×SPDT; 2:2×SPDT; GRT8 A230:AC230V ; W240:AC/DC12V-240V;Rated control supply voltageGRT8 SeriesXFunctionSupply terminalsAC/DC 12-240V(50-60Hz)A1-A2Voltage rangeBurdenVoltage rangeAC 0.09-3VA/DC 0.05-1.7WAC 230V(50-60Hz)AC max.6VA/1.3WAC max.6VA/1.9W-15%;+10%Power inputSupply voltage toleranceTime ranges0.1s-99day,ON,OFFKey settingTime settingTime deviationRepeat accuracy≤1%0.2%-set value stability0.05%/℃,at=20℃(0.05%℉,at=68℉)1×SPDT2×SPDT250VAC/24VDCOutput500mWred LED1×10max.200msMin.breaking capacity DCSwitching voltageCurrent ratingOutput indicationMechanical lifeElectrical life(AC1)Reset time-20℃ to+55℃(-4℉to131℉)-35℃ to+75℃(-22℉to158℉)Din rail EN/IEC 60715IP40 for front panel/IP20 terminalsany
solid wire max.1×2.5or 2×1.5/with sleeve max.1×2.5(AWG 12)
90×18×64mm1×SPDT:W240-62g,A230-60g2×SPDT:W240-82g,A230-81gEN 61812-1,IEC60947-5-1
Operating temperatureStorage temperatureMounting/DIN railProtection degreeOperating positionOvervoltage cathegoryPollution degreeDimensionsWeightStandards20 functions
W240
A230
1×1051×16A(AC1)2×16A(AC1)Temperature coefficientGRT8-X1GRT8-X2Button (Set)
-4-
http://www.geya.net
Disposal of Electrical WasteAll electrical waste should bedisposed of in compliance withcurrent WEEE regulations.CautionThe products must be installed by qualified electricians. All andany electrical connections of the time relay shall comply withthe appropriate safety standards.NOTE: the use case is for reference only to understand the working principle of the relay. The actual application should be wired according to the actual needs.CASE1: The working mode is set to 07 and accessed through the sensor (PNP). When the sensor senses the signal, the relay acts (15-18 is closed) and the ventilation fan works. When the sensor loses the signal, the relay disconnects after a delay t (15-18 is disconnected) and the ventilation fan stops working.Sensor(PNP)BrownBlackFanCASE 2: The working mode is set to 03, the ventilation fan is turned on for 10 hours and turned off for 1 hour, and the ventilation fan is cycled on and off.AC220V~~CASE 3: When the working mode is set to 02, the time relay is powered on (15-18 is closed), the contactor is closed, the water pump starts to work, the delay t reaches, the relay is disconnected (15-18 is disconnected), the contactor is disconnected, and the water pump stops working.PUMPLEDCASE 4: The working mode is set to 08, press the trigger button, the time relay acts (15-18 is closed), turn on the LED, delays t, the relay is disconnected (15-18 is disconnected), and the LED is closed.AC220V~~Trigger buttonFanOutput indication(red)Button (UP)MDR15161815161825262828
95
4.2MDGRT8-X1R0V24VBlueAC220V~~AC220V~~Dimensions(mm)Examples
Short press to enter the delay time settingRunning state
-2-
Fast adjustment of delay timeMHD
0.1M
0.1H0.1SMHD
0.1M
0.1H0.1SSet range:0.1DST1 delay time base setting0.1DSSelect function:01~20Delay function settingPress and hold for 3 seconds to enter / exit the function settingPositive timingCount downNOTE:Short press to adjust the parameter value, long press to realize rapid adjustment, if there is no operation key within 60 seconds, it will automatically exit the setting mode. In the setting mode,You can press and hold the key for 3 seconds to exit and save the settings。Set timing display modeShort press to enter the interface of fast setting delay time, as shown below:Long press 3 seconds to enter the function mode parameter setting interface, as shown below:Delay time T1 settingThe delay time T2 setting ,this option is not available when the function mode is single delay timeAdjustment of the productShort press to adjust the parameter value, long press to realize rapid adjustment (when the value exceeds 99, it will start from 0)Short press to adjust the parameter value, long press to realize rapid adjustment (when the value exceeds 99, it will start from 0)Running stateT1 delay time base setting ,this option is not available when the function mode is single delay timeSet range:This option is not available when the function mode is single delay timeSet range:Delay function setting
-3-
When the relay Un is in the power on state, when the S control terminal is connected, the relay will be closed immediately. When the Scontrol terminal is disconnected, the delay will start. After the delay t, the output contact will be disconnected. During the delay process, the S control terminal will be connected and disconnected again, and the delay t will be cleared and delayed again。When the relay Un is in the energized state, when the S control terminal is connected, the relay is closed, and the relay starts to delay. After the delay t, the output contact is disconnected. During the delay t, the S control terminal is connected again, and the delay t remains unchanged and continues to delay.When the relay Un is in the energized state, when the S control terminal is disconnected, the relay is closed, and the relay starts to delay. After the delay t, the output contact is disconnected. During the delay t, the S control terminal is switched on and off again, and the delay t remains unchanged and continues to delay.t1t1Unt1t2When relay Un is powered on, the relay starts to delay. After delay t1, the output contact is closed. At the same time, after delay t2, the relay is disconnected and maintained. After relay Un is powered off, the output contact is disconnected. S control signal is invalid in this function mode.<tWhen the relay Un is in the power on state, when the S control terminal is connected, the relay starts to delay. After the delay t, the output contact is closed. When the S control terminal is disconnected, the output contact is disconnected.When relay Un is powered on, the relay starts to delay, and the output contact is closed after delay t. After the relay Un is de energized, the output contact is disconnected and the S control signal is invalid in this function mode.When relay Un is powered on, the relay output contact will be closed immediately and start delay. After delay t, the output contact will be disconnected. If the delay time t does not arrive and relay Un is powered off, the output contact will be disconnected, and the S control signal is invalid in this function mode.When relay Un is powered on, the relay starts to delay. After delay t1, the output contact is closed. At the same time, after delay t2, the relay output contact is disconnected. In this way, the cycle delay is delayed until relay Unis powered off, and the S control signal is invalid in this function mode.When the relay Un is powered on, the relay is closed and begins to delay. After the delay t2, the output contact is disconnected. At the same time, after the delay time t1, the relay output contact is closed. In this way, the cycle delay is delayed until the relay Un is powered off, and the S control signal is invalid in this function mode.Un01UnUnUnt1t2t1t2t1t2t1t1tWhen the relay Un is in the energized state, when the S control terminal is connected, therelay starts to delay, and the output contact is closed after delay t1. When the S control terminal is disconnected, the relay starts to delay, and the output contact is opened after delay t2.When the relay us is energized and the S control terminal is connected, the relay output contact state changes.t1t2t1t2When the relay us is in the energized state, the S terminal is closed and the relay starts to delay. After the delay T1, the output contact is closed. At the same time, after the delay T2, the relay output contact is disconnected. This cycle delays until the S terminal is disconnected.The relay Un is in the energized state, the S terminal is closed, the relay is closed and begins to delay, the output contact is disconnected after delay t2, and the relay output contact is closed after delay time t1. This cycle delays until the S terminal is disconnected.t2Relay Un is in the energized state. When terminal S is closed, the relay starts to delay. After delay T1, the output contact is closed. At the same time, after delay T2, the relay is disconnected. t2Relay Un is in the energized state. When terminal S is triggered, the relay starts to delay. After delay t1, the output contact is closed and held. When terminal S is triggered again, the relay starts to delay. After delay t2, the relay is disconnected.t1t2The relay Un is in the energized state. When the S terminal is closed, the relay starts to delay. After the delay t, the output contact is closed and held. When the relay Un is disconnected, the relay is disconnected.02030405060606070608060910111213141517t2t1Relay Un is in the energized state. When terminal S is closed, the relay is closed and starts to delay. After delay t1, the output contact is disconnected. When terminal S is disconnected, the relay is closed again and starts to delay. After delay t2, the relay is disconnected.16t2t1+t2t2t1t2t1t2t1t2t1t2t1t2t1t2t2t1t2t1t2UnRelay Un is energized or de energized, and bothrelays are disconnected.20UnRelay Un is in the energized state, the relay is closed, Un is in the de energized state, and the relay is disconnected.19tRelay Un is in the energized state. When terminal S is triggered, the relay starts to delay, and the output contact closes after delay t. when terminal S is triggered again, the relay opens and starts to delay, and the output contact closes after delay t. When relay Un is off, the relay is off.18tOn Delay (Power On)Interval (Power On)
Repeat cycle (Starting Off )Repeat cycle (Starting On)Pulse generator(Power On)
On delay with external contorl Off delay with external startPulse I with external startPulse II with external startOn/off delay with external contorl
Latching relayRepeat cycle with external contorl (Starting Off )Repeat cycle with external contorl (Starting On)Pulse generator with external start
Start-stopDouble delay off with external controlOn delay I by external startOn delay II with external startAlways ONAlways OFFFunction

This manual suits for next models

1

Other GEYA Relay manuals

GEYA GRT8-TS Series User manual

GEYA

GEYA GRT8-TS Series User manual

GEYA GRT8-S1 User manual

GEYA

GEYA GRT8-S1 User manual

GEYA GRT8-P User manual

GEYA

GEYA GRT8-P User manual

GEYA GRT8-D User manual

GEYA

GEYA GRT8-D User manual

GEYA GRT8-WS User manual

GEYA

GEYA GRT8-WS User manual

GEYA GRT6-S Series User manual

GEYA

GEYA GRT6-S Series User manual

GEYA GRT8-RL User manual

GEYA

GEYA GRT8-RL User manual

GEYA GRV8-SN User manual

GEYA

GEYA GRV8-SN User manual

Popular Relay manuals by other brands

Pilz P2HZ X1P operating instructions

Pilz

Pilz P2HZ X1P operating instructions

Omron G9SB datasheet

Omron

Omron G9SB datasheet

Ghisalba GH55 operating instructions

Ghisalba

Ghisalba GH55 operating instructions

ABB REL-300 Instruction leaflet

ABB

ABB REL-300 Instruction leaflet

Davin DV-14 manual

Davin

Davin DV-14 manual

Tense MDK-03 quick start guide

Tense

Tense MDK-03 quick start guide

SSP X2 Series operating manual

SSP

SSP X2 Series operating manual

Moeller DILR Series installation instructions

Moeller

Moeller DILR Series installation instructions

W&T MQTT.box operating instructions

W&T

W&T MQTT.box operating instructions

LOVATO ELECTRIC R1D manual

LOVATO ELECTRIC

LOVATO ELECTRIC R1D manual

Tense GKM-01 quick start guide

Tense

Tense GKM-01 quick start guide

Siemens 7SR242 Duobias Commissioning and maintenance guide

Siemens

Siemens 7SR242 Duobias Commissioning and maintenance guide

White Creations ELV8e installation manual

White Creations

White Creations ELV8e installation manual

Gewa GL-RJ user manual

Gewa

Gewa GL-RJ user manual

Siemens 3TK2810-0 operating instructions

Siemens

Siemens 3TK2810-0 operating instructions

Coster RTL 120 manual

Coster

Coster RTL 120 manual

Vega VEGAVIB 62 operating instructions

Vega

Vega VEGAVIB 62 operating instructions

DOLD VARIMETER MK 9064N Monitoring Technique

DOLD

DOLD VARIMETER MK 9064N Monitoring Technique

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.