Short press to enter the delay time settingRunning state
-2-
Fast adjustment of delay timeMHD
0.1M
0.1H0.1SMHD
0.1M
0.1H0.1SSet range:0.1DST1 delay time base setting0.1DSSelect function:01~20Delay function settingPress and hold for 3 seconds to enter / exit the function settingPositive timingCount downNOTE:Short press to adjust the parameter value, long press to realize rapid adjustment, if there is no operation key within 60 seconds, it will automatically exit the setting mode. In the setting mode,You can press and hold the key for 3 seconds to exit and save the settings。Set timing display modeShort press to enter the interface of fast setting delay time, as shown below:Long press 3 seconds to enter the function mode parameter setting interface, as shown below:Delay time T1 settingThe delay time T2 setting ,this option is not available when the function mode is single delay timeAdjustment of the productShort press to adjust the parameter value, long press to realize rapid adjustment (when the value exceeds 99, it will start from 0)Short press to adjust the parameter value, long press to realize rapid adjustment (when the value exceeds 99, it will start from 0)Running stateT1 delay time base setting ,this option is not available when the function mode is single delay timeSet range:This option is not available when the function mode is single delay timeSet range:Delay function setting
-3-
When the relay Un is in the power on state, when the S control terminal is connected, the relay will be closed immediately. When the Scontrol terminal is disconnected, the delay will start. After the delay t, the output contact will be disconnected. During the delay process, the S control terminal will be connected and disconnected again, and the delay t will be cleared and delayed again。When the relay Un is in the energized state, when the S control terminal is connected, the relay is closed, and the relay starts to delay. After the delay t, the output contact is disconnected. During the delay t, the S control terminal is connected again, and the delay t remains unchanged and continues to delay.When the relay Un is in the energized state, when the S control terminal is disconnected, the relay is closed, and the relay starts to delay. After the delay t, the output contact is disconnected. During the delay t, the S control terminal is switched on and off again, and the delay t remains unchanged and continues to delay.t1t1Unt1t2When relay Un is powered on, the relay starts to delay. After delay t1, the output contact is closed. At the same time, after delay t2, the relay is disconnected and maintained. After relay Un is powered off, the output contact is disconnected. S control signal is invalid in this function mode.<tWhen the relay Un is in the power on state, when the S control terminal is connected, the relay starts to delay. After the delay t, the output contact is closed. When the S control terminal is disconnected, the output contact is disconnected.When relay Un is powered on, the relay starts to delay, and the output contact is closed after delay t. After the relay Un is de energized, the output contact is disconnected and the S control signal is invalid in this function mode.When relay Un is powered on, the relay output contact will be closed immediately and start delay. After delay t, the output contact will be disconnected. If the delay time t does not arrive and relay Un is powered off, the output contact will be disconnected, and the S control signal is invalid in this function mode.When relay Un is powered on, the relay starts to delay. After delay t1, the output contact is closed. At the same time, after delay t2, the relay output contact is disconnected. In this way, the cycle delay is delayed until relay Unis powered off, and the S control signal is invalid in this function mode.When the relay Un is powered on, the relay is closed and begins to delay. After the delay t2, the output contact is disconnected. At the same time, after the delay time t1, the relay output contact is closed. In this way, the cycle delay is delayed until the relay Un is powered off, and the S control signal is invalid in this function mode.Un01UnUnUnt1t2t1t2t1t2t1t1tWhen the relay Un is in the energized state, when the S control terminal is connected, therelay starts to delay, and the output contact is closed after delay t1. When the S control terminal is disconnected, the relay starts to delay, and the output contact is opened after delay t2.When the relay us is energized and the S control terminal is connected, the relay output contact state changes.t1t2t1t2When the relay us is in the energized state, the S terminal is closed and the relay starts to delay. After the delay T1, the output contact is closed. At the same time, after the delay T2, the relay output contact is disconnected. This cycle delays until the S terminal is disconnected.The relay Un is in the energized state, the S terminal is closed, the relay is closed and begins to delay, the output contact is disconnected after delay t2, and the relay output contact is closed after delay time t1. This cycle delays until the S terminal is disconnected.t2Relay Un is in the energized state. When terminal S is closed, the relay starts to delay. After delay T1, the output contact is closed. At the same time, after delay T2, the relay is disconnected. t2Relay Un is in the energized state. When terminal S is triggered, the relay starts to delay. After delay t1, the output contact is closed and held. When terminal S is triggered again, the relay starts to delay. After delay t2, the relay is disconnected.t1t2The relay Un is in the energized state. When the S terminal is closed, the relay starts to delay. After the delay t, the output contact is closed and held. When the relay Un is disconnected, the relay is disconnected.02030405060606070608060910111213141517t2t1Relay Un is in the energized state. When terminal S is closed, the relay is closed and starts to delay. After delay t1, the output contact is disconnected. When terminal S is disconnected, the relay is closed again and starts to delay. After delay t2, the relay is disconnected.16t2t1+t2t2t1t2t1t2t1t2t1t2t1t2t1t2t2t1t2t1t2UnRelay Un is energized or de energized, and bothrelays are disconnected.20UnRelay Un is in the energized state, the relay is closed, Un is in the de energized state, and the relay is disconnected.19tRelay Un is in the energized state. When terminal S is triggered, the relay starts to delay, and the output contact closes after delay t. when terminal S is triggered again, the relay opens and starts to delay, and the output contact closes after delay t. When relay Un is off, the relay is off.18tOn Delay (Power On)Interval (Power On)
Repeat cycle (Starting Off )Repeat cycle (Starting On)Pulse generator(Power On)
On delay with external contorl Off delay with external startPulse I with external startPulse II with external startOn/off delay with external contorl
Latching relayRepeat cycle with external contorl (Starting Off )Repeat cycle with external contorl (Starting On)Pulse generator with external start
Start-stopDouble delay off with external controlOn delay I by external startOn delay II with external startAlways ONAlways OFFFunction