Instruction ManualGEYA ELECTRICAL CO.,LTDAdd:Wenzhou Brige Industrial Zone,Beibaixiang Town,Yueqing,Zhejiang,China 325603E-mail:sale@cngeya.comWeb:www.geya.netVoltage / Current Protector GPS8-06GeneralApplications -Overvoltage ,undervoltage and overcurrent protection for household equipment. Function Features -Voltage / current monitoring and protection. -Special metering chips are used to detect voltage, current, electricity, and power. -It is possible to control switches, monitor electrical energy, and set timing for opening and closing through WIFI. -Double bus wiring design stronger ability. -Over / under voltage value and over-current value can be set. -Self reset after fault. -Digital display voltage, current value, fault status can be displayed by LED. -DIN rail mounting. Model and connotationTechnical parametersRated operational currentOFF,230V~300V45~65Hz
AC220V(L-N)
≤1%Rated supply voltageRated supply frequency
Over voltage operation value
Over/under voltage action delay
Reset timePower-up delayMeasurement error-20℃ ~ +60℃-35℃ ~ +75℃Din rail EN/IEC 60715IP40 for front panel/IP20 terminalsany
823668mm××
Operating temperatureStorage temperatureMounting/DIN railProtection degreeOperating positionOvervoltage cathegoryPollution degreeDimensionsWeight
135g
BurdenAC max.3VAGPS8-06Function
Over voltage, under voltage and over current
0.1s~10s140V~210V,OFF
Under voltage operation valueOver current operation value
Over current action delay
Functions DiagramTp:Power-up delay(2~600s)Tr:Reset delay time(2~900s)Tu:Over/under voltage fault action time(0.1~10s)Tc:Overcurrent fault action time(2~600s)
ULED:
<Tu
TpTrTr
ILED:
LED: >I
TpTr
LED: >U
LED: <U
I>Panel DiagramPower open and closeindicatorOver voltage indicatorUnder voltage indicatorOver current indicatorOperating voltage valueOperating current value
32A,40A,50A,63A,80A(AC1)
1~32A,40A,50A,63A,80A
1×101×10Mechanical lifeElectrical life(AC1)4
GPS8
GPS8 SeriesDesign numberU:upper incoming lineD:lower incoming lineIncoming line mode
06
TuTu
<Tu
Tc
Operation voltage range80V~400V(L-N)2s~600s2s~600s2s~900sParameter settingParameterRangeStep valueFactory settingsOver voltage value
OFF,230V~300V
275V1VUnder voltage value
140V~210V,OFF
175V1VOver current value
OFF,1A~32/40/50/63A
32A/40/50/63A0.1AOver current action delay2s~600s5s1sReset time2s~900s30s1sFault resetON-OFFONPower on delay time2s~600s5s1sOver voltage recovery value225V~295V265V1VUnder voltage recovery value145V~215V180V1VVoltage fault action time0.1s~10s0.5s0.1sMPress and hold the setting key for 3 seconds to enter the setting. After modifying the setting, press and hold for 3 seconds to save the setting.1.Used to increase the value when setting parameters.1.Used to reduce the value when setting parameters.2.After exiting the setting, it can be used to manually turn on or off the load.3.If the automatic fault reset function is turned off, this button can be used for manual reset when the fault occurs.
>I<U>U
NOTE:In the power off state, press and hold , and then power on again to restore the factory settings.LCD backlight time10s~900s,ON1s60sM
GPS8-06 63ANNIN>I<U>U
M2.Press and hold for 5 seconds to reconfigure WIFI.
>I<U>U
MWIFI status indication
GPS8-06 63A