Wiring diagram
Commissioning
Operation

2
GEZE SecuLogic emergency exit system
Contents
1 Introduction............................................................................................................................................................5
1.1 Symbols and illustrations ...........................................................................................................................................................................5
1.2 Validity...............................................................................................................................................................................................................5
1.3 Product liability..............................................................................................................................................................................................5
2 Basic safety notes..................................................................................................................................................6
2.1 Intended use ...................................................................................................................................................................................................6
2.2 Safety notes.....................................................................................................................................................................................................6
2.3 Installation information ..............................................................................................................................................................................6
2.4 Safety-conscious working..........................................................................................................................................................................6
2.5 Inspection of the installed system..........................................................................................................................................................6
2.6 Maintenance notes .......................................................................................................................................................................................6
2.7 Disposal.............................................................................................................................................................................................................7
3 Normative requirements....................................................................................................................................7
3.1 Door control unit TZ 320.............................................................................................................................................................................7
3.2 Classication in accordance with DIN EN 13637: 2015.....................................................................................................................7
3.2.1 GEZE SecuLogic with TZ 320 and FTV 320 or MA 500 .....................................................................................................................7
3.2.2 GEZE SecuLogic with TZ 320 and FTÖ 332...........................................................................................................................................7
3.3 Door control unit TZ 321.............................................................................................................................................................................8
3.4 Door control unit TZ 322.............................................................................................................................................................................8
3.5 Emergency exit sign .....................................................................................................................................................................................8
4 Abbreviations .........................................................................................................................................................9
4.1 Colours...............................................................................................................................................................................................................9
4.2 Abbreviations..................................................................................................................................................................................................9
5 Technical data...................................................................................................................................................... 10
5.1 Technical data GEZE SecuLogic emergency exit system............................................................................................................. 10
5.2 Door control unit TZ 32x.......................................................................................................................................................................... 10
5.2.1 Variants........................................................................................................................................................................................................... 10
5.2.2 Power supply................................................................................................................................................................................................ 10
5.2.2.1 Variants with integrated power supply............................................................................................................................................................10
5.2.2.2 Variants without integrated power supply ...................................................................................................................................................10
5.2.3 Installation .................................................................................................................................................................................................... 10
5.2.4 Components..................................................................................................................................................................................................11
5.2.5 Ribbon cable .................................................................................................................................................................................................12
5.2.5.1 Assignment ribbon cable......................................................................................................................................................................................12
5.2.6 Emergency exit sign (FWS).......................................................................................................................................................................12
5.2.6.1 Variants.........................................................................................................................................................................................................................12
5.2.6.2 Power supply FWS 320 B........................................................................................................................................................................................12
5.2.6.3 Installation ..................................................................................................................................................................................................................12
5.2.7 Key switch SCT 320......................................................................................................................................................................................12
5.2.7.1 Power supply..............................................................................................................................................................................................................12
5.2.7.2 Installation .................................................................................................................................................................................................................12
5.2.7.3 Terminal assignment SCT 320..............................................................................................................................................................................12
5.2.8 Door controller TST 32x.............................................................................................................................................................................13
5.2.8.1 Variants.........................................................................................................................................................................................................................13
5.2.8.2 Terminal assignment...............................................................................................................................................................................................13
5.3 Emergency push button NOT 320.........................................................................................................................................................14
5.3.1 Power supply.................................................................................................................................................................................................14
5.3.2 Installation .....................................................................................................................................................................................................14
5.3.3 Terminal assignment..................................................................................................................................................................................14
5.4 Door terminal T 320....................................................................................................................................................................................14
5.4.1 Power supply.................................................................................................................................................................................................14
5.4.2 Installation .....................................................................................................................................................................................................14
5.4.3 Components..................................................................................................................................................................................................15
5.4.4 Ribbon cable ................................................................................................................................................................................................ 16

3
GEZE SecuLogic emergency exit system
5.4.5 Emergency exit sign (FWS)...................................................................................................................................................................... 16
5.4.6 Key switch SCT 320..................................................................................................................................................................................... 16
5.4.7 Control door terminal TAN 320.............................................................................................................................................................. 16
5.4.7.1 Terminal assignment TAN 320 .............................................................................................................................................................................16
5.5 Terminal box KL 220 ...................................................................................................................................................................................17
5.5.1 Power supply.................................................................................................................................................................................................17
5.5.2 Installation .....................................................................................................................................................................................................17
5.5.3 Terminal assignment..................................................................................................................................................................................17
6 Installation of door control unit TZ 32x and door terminal T 320......................................................19
6.1 Position of the emergency push button.............................................................................................................................................19
6.2 Replacing the lock cylinder .....................................................................................................................................................................19
6.3 Installation UP door control unit and UP door terminal.............................................................................................................. 20
6.3.1 Fasten the impact cover to the support ring ................................................................................................................................... 23
6.3.2 Fastening the key switch .........................................................................................................................................................................23
6.4 Installation AP door control unit and AP door terminal .............................................................................................................. 24
6.4.1 Installation of the door control unit in the stainless steel UP or AP box. .............................................................................. 26
7 Wiring diagram ................................................................................................................................................... 29
7.1 Mains connection of the door control unit TZ 32x ........................................................................................................................ 29
7.1.1 Power supplies............................................................................................................................................................................................. 29
7.1.2 Mains connection of the TZ 32x UP variants.................................................................................................................................... 30
7.1.3 Mains connection of the TZ 32x AP variants.................................................................................................................................... 30
7.1.4 Mains connection of the TZ 32x variants in the UP or AP stainless steel box...................................................................... 30
7.1.4.1 Installation of the mains connection terminal and mains connection................................................................................................31
7.1.5 Uninterruptible power supply STEP UPS........................................................................................................................................... 32
7.2 Locking mechanism................................................................................................................................................................................... 32
7.2.1 Escape door lock FTV 320........................................................................................................................................................................ 32
7.2.2 Holding magnet MA 500 ......................................................................................................................................................................... 33
7.2.3 Emergency exit electric strike FTÖ 332 .............................................................................................................................................. 33
7.2.4 Operation without locking mechanism............................................................................................................................................. 34
7.3 External / central emergency push button ...................................................................................................................................... 35
7.3.1 External emergency button................................................................................................................................................................... 35
7.3.1.1 Emergency push button NOT 220 .....................................................................................................................................................................35
7.3.1.2 Emergency push button NOT 320......................................................................................................................................................................36
7.3.1.3 External emergency button in the door terminal T 320............................................................................................................................36
7.3.2 Central emergency push button .......................................................................................................................................................... 37
7.3.2.1 Emergency push button NOT 220 .....................................................................................................................................................................37
7.3.2.2 Emergency push button NOT 320 ....................................................................................................................................................................38
7.3.2.3 Emergency-o panel in the door panel TE 220 ...........................................................................................................................................39
7.4 External key switch for controlling the door control unit........................................................................................................... 39
7.4.1 Key switch SCT 220 .................................................................................................................................................................................... 39
7.4.2 Key switch SCT 222 ....................................................................................................................................................................................40
7.4.3 Key switch SCT 320......................................................................................................................................................................................41
7.5 Panic lock .......................................................................................................................................................................................................41
7.5.1 Contact lock IQ lock C................................................................................................................................................................................41
7.5.2 Lever lock IQ lock EM..................................................................................................................................................................................41
7.5.3 Motor lock IQ lock EL with MST 210..................................................................................................................................................... 42
7.6 Automatic swing door drive................................................................................................................................................................... 43
7.6.1 Swing door drive Powerturn.................................................................................................................................................................. 43
7.6.2 Swing door drive EMD.............................................................................................................................................................................. 45
7.6.2.1 Operating EMD via internal programme switch...........................................................................................................................................45
7.6.2.2 Operating EMD via DPS, TPS or MPS.................................................................................................................................................................45
7.7 Congurable inputs...................................................................................................................................................................................46
7.7.1 Sabotage........................................................................................................................................................................................................ 47
7.7.2 Short-time unlocking................................................................................................................................................................................ 47
7.7.2.1 Key switch SCT 220 ..................................................................................................................................................................................................47
7.7.2.2 Key switch SCT 221.................................................................................................................................................................................................. 48
7.7.2.3 Number code lock TOPLOCK CTI, CTI B........................................................................................................................................................... 48
7.7.2.4 Number code lock TOPLOCK CTS V, CTS BV...................................................................................................................................................49

4
GEZE SecuLogic emergency exit system
7.7.3 Emergency unlocking via BMA or RWA.............................................................................................................................................. 49
7.8 Congurable outputs................................................................................................................................................................................ 50
7.8.1 Indicator lamp or alarm ........................................................................................................................................................................... 50
7.9 Terminal box KL220 ................................................................................................................................................................................... 50
7.10 GEZE bus........................................................................................................................................................................................................ 51
7.10.1 GEZE bus terminating resistor ............................................................................................................................................................... 52
7.10.1.1 Door control unit TZ 32x .......................................................................................................................................................................................52
7.10.1.2 Master panel MTA 220 (panel TE 220) ..............................................................................................................................................................52
7.10.2 GEZE bus........................................................................................................................................................................................................ 52
7.10.3 Emergency unlocking via GEZE bus.................................................................................................................................................... 52
8 Commissioning................................................................................................................................................... 53
8.1 Service mode ............................................................................................................................................................................................... 53
8.1.1 Switching service mode on .................................................................................................................................................................... 53
8.1.2 Switching service mode o .................................................................................................................................................................... 53
8.1.3 Connecting service terminal ST 220 to the door control unit ................................................................................................... 54
8.1.4 Switching the service terminal ST 220 o ......................................................................................................................................... 54
8.1.5 Service menu ST 220................................................................................................................................................................................. 55
8.2 Display of alarms and faults.................................................................................................................................................................... 63
8.2.1 Display of alarms......................................................................................................................................................................................... 63
8.2.2 Display of faults........................................................................................................................................................................................... 63
9 Operation..............................................................................................................................................................64
9.1 Signals.............................................................................................................................................................................................................64
9.1.1 Alarm signals ................................................................................................................................................................................................ 64
9.1.2 Alarm tones...................................................................................................................................................................................................64
9.2 Controlling the door control unit via key switch............................................................................................................................ 65
9.2.1 Unlocking the door.................................................................................................................................................................................... 65
9.2.2 Locking the door.........................................................................................................................................................................................66
9.2.3 Unlocking the door for a limited time (short-time unlocking)..................................................................................................66
9.3 Unlocking the door in an emergency................................................................................................................................................. 66
9.4 Resetting alarm ........................................................................................................................................................................................... 67
9.4.1 Resetting door alarm ................................................................................................................................................................................ 67
9.4.2 Resetting disconnection.......................................................................................................................................................................... 67
9.4.3 Resetting emergency unlocking .......................................................................................................................................................... 67
9.4.4 Resetting sabotage alarm ....................................................................................................................................................................... 67
9.4.5 Acknowledging alarm with key switch ..............................................................................................................................................68
9.5 Power failure ................................................................................................................................................................................................ 68
9.6 Maintenance................................................................................................................................................................................................. 68

5
GEZE SecuLogic emergency exit system
1 Introduction
1.1 Symbols and illustrations
Warning notices
In these instructions, warning notices are used to warn against material damage and injuries.
XAlways read and observe these warning notices.
XObserve all measures marked with the warning symbol and warning word.
Warning
symbol
Warning
word
Meaning
DANGER Danger to persons.
Non-compliance will result in death or serious injuries.
WARNING Danger to persons.
Non-compliance can result in death or serious injuries.
CAUTION Danger to persons.
Non-compliance can result in minor injuries.
Further symbols and illustrations
Important information and technical notes are highlighted to explain correct operation.
Symbol Meaning
means “important note”
Information to prevent property damage, to understand or optimise the workows
means “additional Information”
XSymbol for an action: This means you have to do something.
If there are several actions to be taken, keep to the given order.
Symbol Meaning Use
EltVTR conforms to EltVTR
Directive on the electrical interlocking of doors
inescape routes (EltVTR)
Note must always be heeded, if conformity with
EltVTR is required.
EN 13637 conforms to DIN EN 13637: 2015
Electrically controlled emergency exit systems
for doors on escape routes
Note must always be heeded, if conformity with
DIN EN 13637: 2015 is required.
1.2 Validity
Valid from software
àTST 320, TST 322 Version V1.1
àTST 321 Version V1.1
1.3 Product liability
In compliance with the liability of the manufacturer for his products as dened in the German “Product Liability
Act”, compliance with the information contained in this brochure (product information and intended use, misuse,
product performance, product maintenance, obligations to provide information and instructions) must be en-
sured. Failure to comply releases the manufacturer from his statutory liability.

6
GEZE SecuLogic emergency exit system
2 Basic safety notes
To ensure personal safety, it is important to follow these safety instructions.
These instructions must be kept.
2.1 Intended use
The GEZE SecuLogic emergency exit system has been designed for controlling and monitoring electrically locked
escape routes.
2.2 Safety notes
àOnly specialists who are authorised by GEZE are permitted to carry out installation, commissioning and maintenance.
àIf unauthorised changes are made to the system, GEZE cannot be made liable in any way whatsoever for any
resulting damages.
àGEZE does not accept any warranty for combinations with third-party products. In addition, only original GEZE
parts may be used for repair and maintenance work.
àThe connection to the mains voltage must be carried out by a qualied electrician. Perform the mains connec-
tion and protective earth connection test in accordance with VDE 0100 Part 600.
àSabotage-resistant cable laying in accordance with VDE 0833 (AP cables in steel hose)
àObserve the latest versions of guidelines, standards and country-specic regulations, in particular:
àDirective on electrical interlocking of doors in escape routes
àDIN EN 13637: 2015 “Electrically controlled emergency exit systems for doors on escape routes”
àDIN VDE 100-600 “Installation of low-voltage systems - Part 6 Tests”
àDIN EN 60335-2-103 “Safety of electrical devices for home use and similar purposes, special requirements
for drives for gates, doors and windows”
àAccident-prevention regulations, especially DGUV V1 (BGV A1) “General regulations”
àDGUV V3 (BGV A3) “Electrical installations and equipment”
2.3 Installation information
àThe GEZE SecuLogic emergency exit system is designed exclusively for use in dry areas.
àCables laid in accordance with GEZE cable plan.
àUse only the cables specied on the cable plan provided. Cables must be shielded in compliance with the wiring diagram.
àAlways use insulated wire-end ferrules for wire cores.
àInsulate wires that are not used.
àSecure loose cables with cable ties.
2.4 Safety-conscious working
DANGER
Danger of fatal injury due to electric shock!
When an Uninterruptible Power Supply is used, the system will still be under voltage even when
disconnected from the mains.
XBefore working on the electrical system, interrupt the power supply (mains and rechargeable
battery) and check that no voltage is present.
XSecure workplace against unauthorised entry
2.5 Inspection of the installed system
XCheck the necessary protective earth connection to metal parts that can be touched.
XCheck the doubled/reinforced insulation of the power cables or mains connection.
2.6 Maintenance notes
XHave doors with electric locking mechanisms on rescue routes inspected annually by an expert.
This expert must
issue a certicate of the recurring inspection, which the operator must submit to the building supervisory
authority on request. The inspection can be carried out by GEZE Service within the context of a maintenance
contract or by a specialist company authorised by GEZE. The checklists in the log book must be used when the
inspection is carried out. GEZE recommends using the log book for documentation of the annual inspection.
EltVTR
EN 13637

7
GEZE SecuLogic emergency exit system
2.7 Disposal
The GEZE SecuLogic emergency exit system is made of materials that should be recycled. For this purpose,
theindividual components should be sorted corresponding to material type:
àAluminium
àIron (ttings, screws, ...)
àPlastic (housing, ...)
àElectronic parts (locking mechanism, motor gear unit, control unit, power supply, sensors, ...)
àCables
àRechargeable battery
The parts can be disposed of at the local recycling depot or by a scrap recycling company.
Rechargeable batteries contain pollutants and heavy metals. Do not dispose of these with household waste.
Onlydispose of rechargeable batteries at the collecting points prescribed by law.
Information on the German Battery Directive
Batteries and rechargeable batteries supplied by GEZE include a supplementary sheet with information on the
provisions of the German Battery Directive regarding the disposal and return of used batteries and rechargeable
batteries.
These instructions must always be followed and observed.
3 Normative requirements
3.1 Door control unit TZ 320
The GEZE SecuLogic emergency exit system - TZ 320 - is approved in accordance with
àEltVTR
Directive on the electrical interlocking of doors in escape routes
and is tested, certied and monitored in accordance with
àDIN EN 13637: 2015
Locks and building hardware - Electrically controlled emergency exit systems for doors on escape routes -
Requirements and test methods
checked, certied and monitored.
3.2 Classication in accordance with DIN EN 13637: 2015
3.2.1 GEZE SecuLogic with TZ 320 and FTV 320 or MA 500
375
0/A/B
1 0 5 5 0 0 B
GEZE SecuLogic comprising TZ 320 with FTV 320 or MA 500 is an electrically controlled emergency exit system,
àthat has been tested with 200 000 cycles,
àfor door leaves with a weight of up to 200 kg and a closing force of no more than 25 N
àthat is suitable for use on re protection/smoke protection doors (depending on the certication of the es-
cape door lock)
àIP30, suitable for use inside,
àwith a safety/retention force from outside of 5 000 N,
àwith a safety/retention force from inside of 5 000 N,
àwithout time delay,
àwithout blocking release,
àwith a triggering element that is mounted outside the door leaf.
3.2.2 GEZE SecuLogic with TZ 320 and FTÖ 332
372
0/A/B
1 0 3 3 0 0 B
GEZE SecuLogic comprising TZ 320 with FTÖ 332 is an electrically controlled emergency exit system,
àthat has been tested with 200 000 cycles,
àfor door leaves with a weight of up to 200 kg and a closing force of no more than 50 N
EN 13637
EN 13637

8
GEZE SecuLogic emergency exit system
àthat is suitable for use on re protection/smoke protection doors (depending on the certication of the escape door lock)
àIP30, suitable for use inside,
àwith a safety/retention force from outside of 5 000 N,
àwith a safety/retention force from inside of 5 000 N,
àwithout time delay,
àwithout blocking release,
àwith a triggering element that is mounted outside the door leaf.
3.3 Door control unit TZ 321
The GEZE SecuLogic emergency exit system - TZ 321 - with delayed emergency button - does not comply with
the requirements of EltVTR or DIN EN 13637: 2015. Use of the TZ 321 in Germany must be applied for byagree-
ment in individual case or project-related construction technique permit in accordance with the relevant
regional government building laws (national regulations).
3.4 Door control unit TZ 322
Without an additional external emergency button on the door, the GEZE SecuLogic emergency exit system - TZ 322-
without emergency push button - does not comply with the requirements of EltVTR nor DIN EN 13637: 2015. Use of
the TZ 322 without an additional external emergency button on the door in Germany must be applied for by agree-
ment in individual case or project-related construction technique permit in accordance with the relevant regional
government building laws (national regulations).
3.5 Emergency exit sign
EltVTR requires this emergency exit sign: EMERGENCY
PUSH-BUTTON
Only press in an emergency
DIN EN 13637:2015 requires this emergency exit sign:
The variants of TZ 320 which have been tested in accordance with DIN EN 13637:2015, receive the emergency
exit sign with the pictogram in accordance with DIN EN 13637:2015. For operation of these variants in accordance
with EltVTR in Germany, an emergency exit sign with the pictogram in accordance with EltVTR must be attached
in addition to the pictogram in accordance with DIN EN 13637:2015. The requirement and operation in accord-
ance with EltVTR are dened in the relevant regional government building ordinance.
The system components permissible in accordance with
EltVTR can be found in the current annex to the type
examination certicate:
The congurations tested to DIN EN 13637:2015 are
named in the certicate with the respective classica-
tion key:
EltVTR
EN 13637
EltVTR
EN 13637
EltVTR
EN 13637
EltVTR
EltVTR
EN 13637

9
GEZE SecuLogic emergency exit system
4 Abbreviations
4.1 Colours
Colour Description Colour Description
BN brown PK pink
BK black RD red
BU blue TQ turquoise
GN green VT violet
GY grey WH white
OG orange YE yellow
4.2 Abbreviations
Abbreviation Description
AC Alternating current
AP Surface-mounted installation
BMA Fire alarm system
CAN GEZE bus (Controller Area Network)
DC Direct current
EMA Burglar alarm system
FF Finished oor level
LED Light emitting diode
NC Potential-free opener contact (normally closed)
NO Potential-free normally open contact (normally open)
NT Power supply
PA Congurable output
PE Congurable input
RS485 Serial communication
RWA Smoke/heat extraction system
SA Sabotage contact
UP Flush-mounted installation
ZSU Timer

10
GEZE SecuLogic emergency exit system
5 Technical data
5.1 Technical data GEZE SecuLogic emergency exit system
Temperature –10 °C … +55 °C
Storage temperature –20 °C … +80 °C
Humidity up to 85%, non-condensing
Altitude above sea level max. 3000 m
IP rating (DIN EN 60529) IP30
Installation only in dry areas (DIN VDE 0100-200)
electrical safety DIN EN 62368-1
DIN EN 60950-1
Guidelines EltVTR
DIN EN 13637: 2015
5.2 Door control unit TZ 32x
5.2.1 Variants
TZ 320 Door control unit with GEZE bus
TZ 321 Door control unit with GEZE bus and delayed emergency button
TZ 322 Door control unit with GEZE bus without emergency push button
Index B with illuminated emergency exit sign
Index S with key switch
Index N with integrated power supply
5.2.2 Power supply
Mains connection Fixed connection (installation cable)
Secondary voltage
(for external components)
24 V DC ±5%, SELV
5.2.2.1 Variants with integrated power supply
Power supply 230 V AC ±5%, 50 Hz
UP variants
Power supply NET 320, 750 mA
Power supply NT 1.1A-24V U P, 1100 mA
AP variants
Power supply NT19.2-24, 800 mA
Power supply NT 1.1A-24V UP, 1100 mA
Variants in UP or
AP stainless steel box
Power supply NET 320, 750 mA
Power supply NT 1.1A-24V UP, 1100 mA
5.2.2.2 Variants without integrated power supply
Power supply 24 V DC, ±5%
Power supply NT6.25A-24 HS, 6250 mA
5.2.3 Installation
UP variants in UP boxes: diameter 60 mm, depth 62 mm
AP variants in AP-housing: 77 mm x 197 mm x 88 mm (W x H x D)
Variants in stainless steel box in UP, AP stainless steel box: 78 mm x 240 mm x 69 mm (W x H x D)
Front plate: 98 mm x 260 mm x 1.5 mm (W x H x D)
EltVTR
EN 13637
EltVTR
EN 13637
EltVTR
EN 13637

11
GEZE SecuLogic emergency exit system
5.2.4 Components
FWS 320 B
X1 Ribbon cable to SCT 320 or TST 320
X1
SCT 320
X1 Key switch
X2 Ribbon cable to FWS 320 B
X3 Ribbon cable to TST 320
2 12 11 54
X1
X2 X3
TST 32x
9
5
1
6
7
3
8
2
4
2 12 11
X1 X2-BK
F1
X3-RD X4-BU
X5-GN X6-OG
1 3 46 45 42 41
12 7 8 53 52 9 2 2 15 14 6 5
21 51 502 22 21
1234
12
J3
J1 J2
1 LED – status locking mechanism F1 Fuse 24 V
2 LED – door status 1.5 A, SMF 125 V, fast-acting, mat. no. 138362
3 LED – alarm / fault X1 Ribbon cable to SCT 320 or FWS 320 B
4
Emergency push button illuminated (not with TST 322)
X2 SCT external
5 Infrared interface for ST 220 X3 GEZE bus, supply, T 320, KL 220
6 Sabotage contact X4 PA
7 Reset switch X5 indirect disconnection
8 Buzzer (75 dB at 50 cm) X6 Locking mechanism inputs, PE
9 Programming interface J1, J2 Indirect disconnection
J3 GEZE bus terminating resistor

12
GEZE SecuLogic emergency exit system
5.2.5 Ribbon cable
Ribbon cable, mat. no. 131823
5.2.5.1 Assignment ribbon cable
Terminal panel Terminal Function
FWS 320 B – X1 1 24V
SCT 320 – X2, X3 2 SCT 320 (unlock, acknowledge alarm)
TST 32x – X1 3 SCT 320 (lock, short-time unlocking, acknowledge alarm)
4 SCT 320 SA
5 5V
6 GND
5.2.6 Emergency exit sign (FWS)
5.2.6.1 Variants
FWS, EltVTR, 1 x arrow down, 1 x arrow up, mat. no. 157337
FWS, EltVTR, 1 x arrow left, 1 x arrow right, mat. no. 157338
FWS 320 B, EltVTR, illuminated, mat. no. 130383
EMERGENCY
PUSH-BUTTON
Only press in an emergency
FWS, EN13673, mat. no. 194035
FWS 320 B, EN13673, illuminated, mat. no. 193554
5.2.6.2 Power supply FWS 320 B
Power supply 24 V DC, ±10%
5.2.6.3 Installation
àMount the emergency exit sign near to the emergency push button.
àThe arrow on the emergency exit sign must be pointing towards the emergency push button.
àThe non-illuminated signs can be mounted in the plexiglass bracket, mat. no. 089361.
5.2.7 Key switch SCT 320
5.2.7.1 Power supply
Power supply 24 V DC, ±10%
5.2.7.2 Installation
UP variant in UP boxes: diameter 60 mm, depth 62 mm
AP variant in AP-housing: 80 mm x 80 mm x 64 mm (W x H x D)
5.2.7.3 Terminal assignment SCT 320
Plug-in and screw terminals, max. cable cross-section: 1 mm²
Terminal panel Terminal Function
X1 2 24V
12 lock
11 unlock
54 SA
EltVTR
EN 13637
EltVTR

13
GEZE SecuLogic emergency exit system
5.2.8 Door controller TST 32x
5.2.8.1 Variants
Door controller TST 320, door controller with GEZE bus, mat. no. 128958
Door controller TST 321, door controller with GEZE bus and delayed emergency button, mat. no. 128960
Door controller TST 322, door controller with GEZE bus, without emergency push button, mat. no. 128959
5.2.8.2 Terminal assignment
Plug-in and screw terminals, max. cable cross-section: 1 mm²
Terminal panel Terminal Function
X2 - BK 2 24V
12 lock, short-time unlocking, acknowledge
11 unlock, acknowledge
X3 - RD 1 GND
3 24VDC (supply)
46 GEZE bus (CAN-H)
45 GEZE bus (CAN-L)
42 RS485-A
41 RS485-B
X4 – BU 2 24V
22 COM PA1
max. 1 A, 30 VDC
21 NO
1 GND
2 24V
51 COM PA2
max. 1 A, 30 VDC
50 NO
X5 – GN 2 24V
1 GND
7 indirect disconnection
8
X6 – OG 53 PE3
52 PE2
9 PE1
2 24V
2 24V
15 closed
14 locked
6 Locking– (GND)
5 Locking+ (24V)

14
GEZE SecuLogic emergency exit system
5.3 Emergency push button NOT 320
5.3.1 Power supply
Power supply 24 V DC, ±10%
5.3.2 Installation
UP variant in UP box: Diameter 60 mm, depth 62 mm
AP variant in AP-housing: 80 mm x 80 mm x 64 mm (W x H x D)
5.3.3 Terminal assignment
1
2
X1
8 8 9 9
31 4 5
X3 X4
X2X5
10 6 7 7
1 Emergency push button illuminated
2 Sabotage contact
Terminal panel Terminal Function
X1 1 GND
3 24VDC (supply)
4 SA
5 SA
X2 7 COM1
7 COM1
X3 8 NO2 (8 and 8 together max. 1A, 30 VDC)
8 NO2
X4 9 COM2
9 COM2
X5 10 NC1 (10 and 6 together max. 1A, 30 VDC)
6 NC1 with terminating resistor 2 kΩ (10 and 6 together max. 1A, 30 VDC)
5.4 Door terminal T 320
5.4.1 Power supply
Power supply 24 V DC, ±10%
5.4.2 Installation
UP variant in UP boxes: diameter 60 mm, depth 62 mm
AP variants in AP-housing: 77 mm x 197 mm x 88 mm (W x H x D)

15
GEZE SecuLogic emergency exit system
5.4.3 Components
FWS 320 B
X1 Ribbon cable to SCT 320 or TAN 320
X1
SCT 320
X1 Key switch
X2 Ribbon cable to FWS 320 B
X3 Ribbon cable to TST 320
2 12 11 54
X1
X2 X3
TAN 320
1
5
3
6
2
4
X2
X1
7
31 7 8 41 42
1 LED – status locking mechanism 7 Programming interface
2 LED – door status X1 Ribbon cable to SCT 320 or FWS 320 B
3 LED – alarm / fault
4 Emergency push button illuminated
5 Sabotage contact
6 Buzzer (75 dB at 50 cm)

GEZE SecuLogic emergency exit system
16
5.4.4 Ribbon cable
see chap. 5.2.5
5.4.5 Emergency exit sign (FWS)
see chap. 5.2.6
5.4.6 Key switch SCT 320
see chap. 5.2.7
5.4.7 Control door terminal TAN 320
Control door terminal TAN 320, mat. no. 141033
5.4.7.1 Terminal assignment TAN 320
Plug-in and screw terminals, max. cable cross-section: 1 mm²
Terminal panel Terminal Function
X2 - BK 1 GND
3 24VDC (supply)
7 indirect disconnection +
8 indirect disconnection -
41 RS485-B
42 RS485-A

17
GEZE SecuLogic emergency exit system
5.5 Terminal box KL 220
Terminal box KL 220 oers 4 additional inputs and 6 additional outputs.
5.5.1 Power supply
Mains connection Fixed connection (installation cable)
Power supply 230 V AC ±10%, 50 Hz
Power supply NT19.2-24, 800 mA
Secondary voltage
(for external components)
24VDC (±5%), SELV
5.5.2 Installation
UP variant in ush-mounted connection box,
107 x 107 x 57 mm (W x H x D)
AP variants in AP housing,
113 mm x 113 mm x 58 mm (W x H x D)
5.5.3 Terminal assignment
F1
X3
302 1
X1
X2 RES
31 32 33 34 35 36 37 38
231 2 24 25 26 27 28 29
19 18 2 17 16 2 42 41 3 1
12
34
24 VDC
RD/BK
230VAC
BU/BN
NT19.2-24
1 Sabotage contact F1 Fuse 24 V
2 LED RD – operation 1.0 A, SMF 125 V, fast-acting, mat. no. 111789
3 Mains connection RES Reserve fuse F1
4 Mains connection terminals X1 Supply, TZ 320,
Additional PE
X2 Additional PA
X3 Additional PA
EltVTR
EN 13637

18
GEZE SecuLogic emergency exit system
Plug-in and screw terminals, max. cable cross-section: 1 mm²
Terminal panel Terminal Function
X1 1 GND
3 24VDC (supply)
41 RS485-B
42 RS485-A
2 24V
16 PE1
17 PE2
2 24V
18 PE3
19 PE4
X2 1 GND
2 24V
23 NO PA1
24 COM max. 1 A, 30 VDC
25 NO PA2
26 COM max. 1 A, 30 VDC
27 NO PA3
28 COM max. 1 A, 30 VDC
29 NC
X3 2 24V
1 GND
30 NO PA4
31 COM max. 1 A, 30 VDC
32 NC
33 NO PA5
34 COM max. 1 A, 30 VDC
35 NC
36 NO PA6
37 COM max. 1 A, 30 VDC
38 NC

19
GEZE SecuLogic emergency exit system
6 Installation of door control unit TZ 32x and door terminal T 320
6.1 Position of the emergency push button
EltVTR Installation height above FF
Distance to the main closing edge of the door
850 mm to 1200 mm
no requirement
Attach the emergency exit sign in such a way that the arrow is pointing towards the emergency push button.
EN 13637 Installation height above FF
Distance to the main closing edge of the door
800 mm to 1200 mm
less than 600 mm
For this reason, GEZE recommends this position for the emergency push button to comply with the requirements
from EltVTR and DIN EN 13637:2015:
1 200 mm
850 mm
90°
600 mm
1 200 mm
850 mm
90°
600 mm
In the case of double-leaf doors, the distance 600 mm refers to the secondary closing edge of the active leaf.
6.2 Replacing the lock cylinder
The lock cylinder installed in the door control unit or the door terminal can be replaced by an on-site
lock cylinder:
àEuro prole half cylinder / 40 mm (30 mm/10mm) / 8-fold adjustment
XUndo the cylinder head screw (1),
XReplace the Euro prole half cylinder and
XFasten with cylinder head screw
1

20
GEZE SecuLogic emergency exit system
6.3 Installation UP door control unit and UP door terminal
Installation is described using the example of TZ 320 BSN, EltVTR:
GeraDevicereference:Powersupply NET320
Output: 24 V===/0.75A/18W (+RD/-BK)
Input: 230V ~ /50HZ/0.2A (BU/BN)
Working temperature: Tu=°20-C...°60+C
Serial no.:
Mat. no.:
Batch.:
1 FWS 320 B
2 UP frame
3 UP power supply
4 Terminals
5 Ribbon cable
6 TST 320
7 SCT 320
XUse UP boxes with a depth of 62.5 mm.
The layout of the assemblies in the UP boxes can be selected as required.
The following must be heeded:
àFor position of the emergency push button, see chap. 6.1
àThe arrow on the emergency exit sign must be pointing towards the emergency push button.
EltVTR
Other manuals for SecuLogic TZ320
2
This manual suits for next models
2
Table of contents
Popular Safety Equipment manuals by other brands

Elcon
Elcon HiD 2000 Series User instruction manual

ABS
ABS ABS-Lock SYS III Safety instructions

Tractel
Tractel derope Series Use and maintenance instructions

Bartec
Bartec ER 100ims Operation manual

HACA LEITERN
HACA LEITERN 0529.74 Instructions for use

ABB
ABB Stanilite Platinum exit LED Quickfit installation manual