Installation Instructions
Installation of the Giant Industries, Inc., pump
is not a complicated procedure, but there are
some basic steps common to all pumps. The
following information is to be considered as
a general outline for installation. If you have
unique requirements, please contact Giant
Industries, Inc. or your local distributor for as-
sistance.
1. The pump should be installed at on a base to
a maximum of a 15 degree angle of inclination to
ensure optimum lubrication.
2. The inlet to the pump should be sized for the
ow rate of the pump with no unnecessary restric-
tions that can cause cavitation. Teon tape should
be used to seal all joints. If pumps are to be oper-
ated at temperatures in excess of 160oF for the
LP122A-3100 pump or 86o F for the LP250-3100
pump, it is important to insure a positive head to
the pump to prevent cavitation.
3. The discharge plumbing from the pump should
be properly sized to the ow rate to prevent line
pressure loss to the work area. It is essential to
provide a safety bypass valve between the pump
and the work area to protect the pump from pres-
sure spikes in the event of a blockage or the use of
a shut-off gun.
Finally, remember that high pressure operation in a pump system has many advantages. But,
if it is used carelessly and without regard to its potential hazard, it can cause serious injury.
IMPORTANT OPERATING CONDITIONS
Failure to comply with any of these conditions invalidates the warranty.
1. Prior to initial operation, add oil to the crankcase
so that oil level is between the two lines on the oil
dipstick. DO NOT OVERFILL.
Use SAE 80-90W Industrial Gear Lube Oil
(p/n 01154)
Crankcase oil should be changed after the rst
50 hours of operation, then at regular intervals of 500
hours or less depending on operating conditions.
4. Use of a dampener is necessary to minimize pul-
sation at drive elements, plumbing, connections, and
other system areas. The use of a dampener with
Giant Industries, Inc. pumps is optional, although
recommended by Giant Industries, Inc. to further
reduce system pulsation. Dampeners can also
reduce the severity of pressure spikes that occur in
systems using a shut-off gun. A dampener must be
positioned downstream from the unloader.
5. Crankshaft rotation on Giant Industries, Inc.
pumps should be made in the direction designated
by the arrows on the pump crankcase. Reverse
rotation may be safely achieved by following a few
guidelines available upon request from Giant Indus-
tries, Inc. Required horsepower for system opera-
tion can be obtained from the charts on pages 3.
6. Before beginning operation of your pumping
system, remember: Check that the crankcase and
seal areas have been properly lubricated per recom-
mended schedules. Do not run the pump dry for
extended periods of time. Cavitation will result in
severe damage. Always remember to check that all
plumbing valves are open and that pumped media
can ow freely to the inlet of the pump.
2. Pump operation must not exceed rated pressure,
volume, or RPM. A pressure relief device must be
installed in the discharge of the system.
3. Acids, alkalines, or abrasive uids cannot be
pumped unless approval in writing is obtained before
operation from Giant Industries, Inc.
4. Run the pump dry approximately 10 seconds to
drain the water before exposure to freezing
temperatures.