Gigabyte H270-T70 User manual

Motherboard Components/ 主板组件
288
287
143
8
9
10
11
12
13 14 16
17 18 19 20
26 25 24 23
33 32 31 30
37 36 35 34
21 22
27
28
2938394142
43
44
45
40
46 47
49
48
15
76
1
2
34
5
No Descripon
1 Power module
2 Power supply board cage
3 PCI Express card
4 Fan duct
5 Memory module
6 System fan #1/#2 (FAN1/FAN2)
7 System fan #3/#4 (FAN3/FAN4)
8 System fan #5/#6 (FAN5/FAN6)
9 System fan #7/#8 (FAN7/FAN8)
10 HDD bays
System Components/系统组件
2
3
4
5
5
4
5
6
7
8
9
6
7
8
9
10
10
5
3
1
PDB Components/配电板组件
No Descripon
1 System fan #1 (FAN1)
2 System fan#2 (FAN2)
3 System fan #3(FAN3)
4 System fan #4 (FAN4)
5 System fan #5 (FAN5)
6 System fan #6 (FAN6)
7 System fan #7 (FAN7)
8 System fan #8 (FAN8)
Power Distribuon Board Components
1
2
3
4
5
6
7
8
Front Panel Header/ 前面板接头
No. Pin Define
1 PS_ON_N_LF
3 FP_PSU
5 BMC_FCB_N
7 Power Buon
9 ACK_BMC_N
11 GND
No. Pin Define
2 SMBus Clock
4 SMBus Data
6 System Status LED (Green)
8 System Status LED (Amber)
10 ID LED
12 ID Buon
SATA SGPIO Header/SATA SGPIO 接头
No. Pin Define
1 SGPIO_SATA_DATAOUT_R
2 GND
3 SGPIO_SATA_DIN
4 SGPIO_SATA_LOAD_R
5 SGPIO_SATA_CLOCK_R
1 5
12
1211
Power Supply Board Cage/电源箱
1
2
CAUTION!
Before you remove or install power
supply board cage cover:
Make sure the system is not turned on
or connected to AC power.
CPU0: CPU1:
Heat Sink/ 散热装置
1CPU1
3
2
CPU0
Memory Populaon Configuraon/ 安装内存
Rank(s) 1 Rank 2 Rank
x8,x16 x8,x16
1 Rank 2 Rank
x8,x16 x8,x16
8 8,16 8 8,16
 
 
 
 
 
 
Data Width
Per DIMM Capacity (GB)
1600MTS
1866MTS
2133MTS
1 DIMM per channel 2 DIMM per channel#DIMM per channel
DDR4 UDIMM Configuration
Rank(s) 1 Rank
x4
8,16



x8
4,8



2 Rank
x4
16,32



x8
8,16



1 Rank
x4
8,16


x8
4,8


2 Rank
x4
16,32


x8
8,16


Data Width
Per DIMM Capacity (GB)
1600MTS
1866MTS
2133MTS
1 DIMM per channel 2 DIMM per channel#DIMM per channel
DDR4 RDIMM Configuration
 DIMM must be populated starng from DIMM_P0_A0/DIMM_P0_B0 socket and must be installed in
matched pairs.
 One CPU only supports the populaon of 2/4 (1DPC)/8 (2DPC) in the same me.
 System will not boot normally with incorrect populated sequence.
 DIMM必须从DIMM_P0_A0//DIMM_P0_B0插槽开始按顺序安装。DIMM必须成对安装。
 只能支持一個CPU同時上2/4 (1DPC)/8(2DPC)數量的DIMM。
 若安装顺序有误,系统将无法正常开机。
Fan Duct/ 导风罩
注意!
确保系统未开机且未连接到交流电源。
断开所有必要的线缆连接。若不遵循
这些警告,可能造成人员伤害或设备
损坏。
CAUTION!
Before you remove or install the system fan:
 Make sure the system is not turned on or
connected to the AC power.
 Disconnect all necessary cable connecons.
Failure to observe these
warnings could result in personal injury or
damage to the equipment.
System Fan/ 系统风扇
No Descripon
1 SATA0
2 SATA1
3 SATA2
Hard Disk Drive and Back Plane Board/ 硬盘驱动器与硬盘驱动器底板
HDD Backplane Board Components
HDD Installon
2
3
4
1
4
1
2
3
4
5
6
No Descripon
4 SATA4
5 IPMB
6 SATA_SGPIO
System Front View/系统前部概览 System Rear View/系统后部概览
No Descripon
1 HDD Node#1
2 HDD Node#2
3 HDD Node#3
4 HDD Node#4
5 ID buon w/LED
6 VGA port
7 USB 3.0 ports
8 Power buon w/LED
No Descripon
1 VGA port
2 Serial port
3 Power buon w/LED
4 ID buon w/LED
5 NMI buon
6 Reset buon
7 System status LED
8 QSFP+ LAN ports
9 10/100/1000 Server management LAN port
10 USB 3.0 ports
11 Power supply fan
12 Power supply module cord socket
Front & Rear/ 系统前部与后部概览
ID buon/LED:
Blue On
Off
Description
Unit selected for identification.
System is powered off
State
Power buon/LED:
Green On
Off
Description
System is powered on
System is powered off
State
Speed LED Link/Acvity
LED
Off
State Description
Yellow On 1Gbps data rate
Green On 100Mbps data rate
10Mbps data rate
10/100/1000 LAN LED:
State Description
Green On Link between system
and network
Blink LAN is active
Link/Acvity LED:
12
1
5
2
9
8
7
6
10 11
3
4
Speed LED Link/Acvity
LED
7
1
2
3
4
85 6
State Description
Green On 40 Gbps data rate
Yellow On 10 Gbps data rate
QSFP+ LAN LED:
注意!
连接了交流电源时,服务器内可能存在电压。甚至在主电源开关处于关闭位置时,也
存在此电压。在安装PCI卡之前,确保系统处于关机状态并且断开服务器的所有电源。
若不遵循这些警告,可能造成人员伤害或设备损坏。
CAUTION!
Before you remove or install the PCI express card:
 Voltages can be present within the server whenever an AC power source is connected.
This voltage is present even when the main power switch is in the off posion. Ensure that the system is
powered-down and all power sources have been disconnected from the server prior to installing a
PCI express card.
PCI Express Expansion Card/PCI Express 扩展卡
注意!
连接了交流电源时,服务器内可能存在电压。甚至在主电源开关处于关闭位置时,也存
在此电压。在安装附加卡之前,确保系统处于关机状态并且断开服务器的所有电源。
若不遵循这些警告,可能造成人员伤害或设备损坏。
CAUTION!
Before you remove or install the Add-on card:
 Voltages can be present within the server whenever an AC power source is connected.
This voltage is present even when the main power switch is in the off posion. Ensure that the system is
powered-down and all power sources have been disconnected from the server prior to installing an
add-on card.
Add-on Card (Oponal)/ 附加卡 ( 选购 )
12
4
5
3
1
2
3
4
注意!
在替换或安装电源前,请注意下列事项:
确保系统未开启且未连接到交流电源。
注意!
在替换或安装电源主板前,请注意下列事
项:
确保系统未开启且未连接到交流电源。
CAUTION!
Before you remove or install the power
supplies:
Make sure the system is not turned on or
connected to AC power.
Power Supply/ 电源
Rail Kit/ 导轨
Attach therails to therack.
12
PUSH


PUSH
Click!
Click!
⯭㺸彏⭰墬󰶒㜡㟃
!
㜡㟃ḡ㖠⬻㟘
寞㳏ヶ⯭㺸彏⭳㕛
墬⅌㜡㟘⬻Ⅼ
CAUTION!
Post Square stud must
be fullyattached inside
the squarehole on the
rack rail.
Install into thechassis.
Two persons lift required.
Insert thechassisdirectlyonthe Lbracket.
$
%
㭊䡕✗⯭㜡䮘⭰墬⅌⌵彏⤎⏞⏝䈮󰶒
⭰墬㜡䮘
寞䡕ῄ凚⯸ḋạ㒴ὃ⭰墬
Tighten the positioning screws
擨䴎㜡♏ḋᾎ垡Ḅ
1
2
2
Front Panel LEDs and Buons/ 前面板 LED 说明
1
2
H270-T70 Quick Installaon Guide/H270-T70 快速安装说明
No. Code Descripon
1 VGA_1 Rear VGA port
2 F_VGA1 Front VGA header
3 COM1 Rear serial port
4 COM2 Front serial port header
5 SW_PWR Power buon w/LED
6 SW_ID ID switch buon w/LED
7 SW_RST_NMI Reset buon (top)
8 LED_LAN QSFP LAN link/acvity/speed LED for port #1 and port #2
9 QSFP_1 QSFP LAN port #1
10 QSFP_2 QSFP LAN port #2
11 LED_STA System status LED
12 USB3_MLAN BMC management LAN port (top)/USB 3.0 ports (buom)
13 SATA_SGP1 SATA SGPIO header
14 SATA3/SATA2/SATA1 SATA 6Gb/s connectors
15 SATA_DOM0 SATA0 port DOM support jumper
16 SATA0 SATA 6Gb/s connector
17 DIMM_P0_A0 Channel 1 slot 0 (for primary CPU)
18 DIMM_P0_A1 Channel 1 slot 1 (for primary CPU)
19 DIMM_P0_C0 Channel 3 slot 0 (for primary CPU)
20 DIMM_P0_C1 Channel 3 slot 1 (for primary CPU)
No. Code Descripon
21 CPU0 Cavium ThunderX CN88xx ARMv8 SoC processor (Primary CPU)
22 CPU1 Cavium ThunderX CN88xx ARMv8 SoC processor (Secondary CPU)
23 DIMM_P1_H1 Channel 4 slot 1 (for secondary CPU)
24 DIMM_P1_H0 Channel 4 slot 0 (for secondary CPU)
25 DIMM_P1_F1 Channel 2 slot 1 (for secondary CPU)
26 DIMM_P1_F0 Channel 2 slot 0 (for secondary CPU)
27 ATX1 18 pin power connector
28 FP_1 Front panel header
29 ATX2 18 pin power connector
30 DIMM_P1_E0 Channel 1 slot 0 (for secondary CPU)
31 DIMM_P1_E1 Channel 1 slot 1 (for secondary CPU)
32 DIMM_P1_G0 Channel 3 slot 0 (for secondary CPU)
33 DIMM_P1_G1 Channel 3 slot 1 (for secondary CPU)
34 DIMM_P0_B0 Channel 2 slot 0 (for primary CPU)
35 DIMM_P0_B1 Channel 2 slot 1 (for primary CPU)
36 DIMM_P0_D0 Channel 4 slot 0 (for primary CPU)
37 DIMM_P0_D1 Channel 4 slot 1 (for primary CPU)
38 BMC_SGPIO1 BMC SGPIO header
39 IPMB IPMB connector
40 F_USB3 USB 3.0 header
No. Name Color Status Description
Description
1
2
System is operating normally.
Unit selected for identification.
No identification.
Power Button and
Status LED
Green
Amber
Blue
N/A
Solid On
On
Critical condition, may indicates:
Power module failure
System fan failure
Power supply voltage issue
System temperature
Solid On
Non-critical condition, may indicates:
Redundant power module failure
Temperature and voltage issue
Chassis intrusion
System is not ready, may indicates:
POST error
NMI error
Processor or terminator missing
Blink
N/A Off
Off
ID Button w/LED
1系统正常运行。Power Button and
Status LED
编号 名称 颜色 状态 说明
橙色
绿色 恒亮
恒亮
不亮
闪烁
无亮灯
No. Code Descripon
41 S3_MASK S3 Power On Select jumper
1-2 Close: Stop an inial power on when BMC is not ready.
2-3 Close: Keep inial power on. (Default seng)
42 BIOS_PWD Clearing Supervisor Password jumper
1-2 Close: Normal operaon. (Default seng)
2-3 Close: Skip supervisor password.
43 CASE_OPEN Chassis intrusion alert header
44 PCIE_1 Half-length low-profile slot with PCIe x16
(Gen3 x16 bus) connector
45 LED_BMC BMC frmware readiness LED
46 MEZZ_1 Mezzanine PCIe x8 (Gen3 x8 bus) connector
47 BIOS_RCVR BIOS recovery jumper
1-2 Close: Normal operaon. (Default seng)
2-3 Close: BIOS recovery mode.
48 BAT1 Baery socket
49 CLR_CMOS Clear CMOS jumper
1-2 Close: Normal operaon (Default seng)
2-3 Close: Clear CMOS data.
2系统识别功能。
无系统识别功能。
ID按钮和LED 恒亮
不亮无亮灯
蓝色
严重情形,可能为下列状况:
电源模块故障
系统风扇故障
电源电压问题
系统温度/电压问题
非严重情形,可能为下列状况:
冗余电源模块故障
系统温度/电压问题
机箱侵入
系统未正常运行,可能为下列状况:
POST错误
NMI错误
处理器或终结器缺失
PN:25ME0-H27000-CLR
Regulatory Noces
Connect With Us
WEEE Symbol Statement
For more informaon, visit our website at:
hp://b2b.gigabyte.com
You are a professional?
Get access to our complete source of sales & markeng materials at:
hp://reseller.b2b.gigabyte.com
hps://www.facebook.com/gigabyteserver
The symbol shown below is on the product or on its packaging, which indicates that this product must not be disposed of with other
waste. Instead, the device should be taken to the waste collecon centers for acvaon of the treatment, collecon, recycling and
disposal procedure. The separate collecon and recycling of your waste equipment at the me of disposal will help to conserve
natural resources and ensure that it is recycled in a manner that protects human health and the environment.
For more informaon about where you can drop off your waste equipment for recycling, please contact your local government
office, your household waste disposal service or where you purchased the product for details of environmentally safe recycling.
 When your electrical or electronic equipment is no longer useful to you, "take it back" to your local or regional waste
collecon administraon for recycling.
 If you need further assistance in recycling, reusing in your "end of life" product, you may contact us at the Customer Care
number listed in your product's user's manual and we will be glad to help you with your effort.
GIGABYTE产品未故意添加和使用有害物质(Cd、Pb、Hg、Cr+6、PBDE和PBB)。所有部件和元件均经过严格挑选,符合RoHS要求。此
外,我们GIGABYTE一直致力于开发不使用国际上禁止的有毒化学品的产品。
GIGABYTE products have not intended to add and safe from hazardous substances (Cd, Pb, Hg, Cr+6, PBDE and PBB). The parts and components
have been carefully selected to meet RoHS requirement. Moreover, we at GIGABYTE are connuing our efforts to develop products that do not use
internaonally banned toxic chemicals.
Restricon of Hazardous Substances (RoHS) Direcve Statement
This server is intended for installaon only in restricted access locaons where .
• Access can only be gained by SERVICE PERSONS who have been instructed about the reasons for the restricons applied to the
locaon and about any precauons that shall be taken.
• Access is through the use of a TOOL or lock and key, or other means of security, and is controlled by the authority responsible for the locaon.
The following or similar rack-mount instrucons are included with the installaon instrucons:
A) Elevated Operang Ambient - If installed in a closed or mul-unit rack assembly, the operang ambient temperature of the rack environment
may be greater than room ambient. Therefore, consideraon should be given to installing the equipment in an environment compable with the
maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installaon of the equipment in a rack should be such that the amount of air flow required for safe operaon of the
equipment is not compromised.
C) Mechanical Loading - Mounng of the equipment in the rack should be such that a hazardous condion is not achieved due to uneven mechani-
cal loading.
D) Circuit Overloading - Consideraon should be given to the connecon of the equipment to the supply circuit and the effect that overloading of
the circuits might have on overcurrent protecon and supply wiring. Appropriate consideraon of equipment nameplate rangs should be used
when addressing this concern.
E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Parcular aenon should be given to supply connec-
ons other than direct connecons to the branch circuit (e.g. use of power strips)."
Disconnect 2 power supply cords before servicing
This device complies with Part 15 of the FCC Rules.
Operaon is subject to the following two condions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired operaon.
FCC Statement
This equipment should not be operated above an ambient operaon temperature of 35 degrees cengrade.
Ambient Operaon
CAUTION: The power supplies in your system may produce high voltages and energyhazards, which can cause bodily harms. Unless you are
instructed otherwise, only trained service technicians are authorized to remove the covers and access any of the components inside the system.
Power Supply
CAUTION: Do not connect of disconnect any cables or perform installaon, maintenance, or reconfiguraon of this server during an electrical storm
CAUTION: Connect all power cords to a properly wired and grounded electrical outlet.
Reliable Earthing:
CAUTION: This server contains hazardous moving fan blades, keep fingers and other bodyparts away.
Disconnect all power supply cords before servicing. Connect power supply cord only aer all the covers are properly installed.
Hazardous FAN
CAUTION: This server contains hazardous energy over 240VA on the backplane. To prevent accidental short circuit, always insert the
HDD trays aer servicing.
Hazardous Energy
Restricted Access Locaon
The system may have more than one power supply cable. To reduce the risk of electrical shock, a trained service technician may need to disconnect
all power supply cables before servicing the system.
Rack Mount Instrucons
CAN ICES-3 (A)/NMB-3(A)
CAUTION: Slider/rail mounted equipment is not to be
used as a shelf or a work space.
CAUTION: Whenever you need to li the system, get others to assist you.
To avoid injury, do not aempt to li the system by yourself.
限制使用有害物质 (RoHS) 指令声明
California Proposion 65 Warning
WARNING:
This product contains a chemicals , including lead, known to the State of California to cause cancer and birth defects or other reproducve harm.
For more informaon, please visit: hp://www.p65warnings.ca.gov/
Baery Warning:
Incorrectly installing a baery or using incompable baery may increase the risk of ifre explosion. Replace the baery only with
the same or equivalent type.
 Do not disassemble, crush, punchture baeries.
 Do not store or place your baery pack next to or in a heat source such as a fire, heatgenerang appliance, can or exhaust
vent. Heang baery cells to temperatures above 65oC (149oF) can cause explosion or fire.
 Do not aempt to open or service baeries. Do not dispose of baeries in a fire or with household waste.
电池警告:
电池安装不当或使用不兼容的电池会增加火灾爆炸风险。更换电池时,只可使用相同或同等类型的电池。
 请勿拆解、挤压、刺破电池。
 请勿将电池存放或放置在热源中或旁边,如火源、产生热的设备、罐体或排气口。电池温度升至65oC (149oF)以上
可能导致爆炸或火灾。
 请勿尝试打开或维修电池。电池废弃时,请勿投入火中或者作为家庭废弃物进行处理。
依照中华人民共和国的有毒有害物质的限制要求(China RoHS)提供以下的表格:
中华人民共和国电子信息产品中有毒有害物质或元素的名称及含量标识格式
声明 本系统功率大于 1300W

Other Gigabyte Server manuals

Gigabyte G292-Z24 User manual

Gigabyte

Gigabyte G292-Z24 User manual

Gigabyte R162-ZA1 User manual

Gigabyte

Gigabyte R162-ZA1 User manual

Gigabyte DO22-ST0 User manual

Gigabyte

Gigabyte DO22-ST0 User manual

Gigabyte GS-R114L User guide

Gigabyte

Gigabyte GS-R114L User guide

Gigabyte R282-Z93 User manual

Gigabyte

Gigabyte R282-Z93 User manual

Gigabyte R263-Z32-AAD1 User manual

Gigabyte

Gigabyte R263-Z32-AAD1 User manual

Gigabyte TO15-S40-IA01 User manual

Gigabyte

Gigabyte TO15-S40-IA01 User manual

Gigabyte G242-P35 User manual

Gigabyte

Gigabyte G242-P35 User manual

Gigabyte H273-Z82-AAN1 User manual

Gigabyte

Gigabyte H273-Z82-AAN1 User manual

Gigabyte R282-Z97 User manual

Gigabyte

Gigabyte R282-Z97 User manual

Gigabyte GS-R127H-RH User guide

Gigabyte

Gigabyte GS-R127H-RH User guide

Gigabyte ME03-CE0 User manual

Gigabyte

Gigabyte ME03-CE0 User manual

Gigabyte S12-P10R User manual

Gigabyte

Gigabyte S12-P10R User manual

Gigabyte H263-S64-AAN1 User manual

Gigabyte

Gigabyte H263-S64-AAN1 User manual

Gigabyte G293-Z43-AAP1 User manual

Gigabyte

Gigabyte G293-Z43-AAP1 User manual

Gigabyte W733-W30 User manual

Gigabyte

Gigabyte W733-W30 User manual

Gigabyte R183-S93-AAC1 User manual

Gigabyte

Gigabyte R183-S93-AAC1 User manual

Gigabyte G242-P33 User manual

Gigabyte

Gigabyte G242-P33 User manual

Gigabyte G262-ZO0 User manual

Gigabyte

Gigabyte G262-ZO0 User manual

Gigabyte E152-ZE1 User manual

Gigabyte

Gigabyte E152-ZE1 User manual

Gigabyte R272-P30 User manual

Gigabyte

Gigabyte R272-P30 User manual

Gigabyte E152-ZE0 User manual

Gigabyte

Gigabyte E152-ZE0 User manual

Gigabyte E243-E30-AAD1 User manual

Gigabyte

Gigabyte E243-E30-AAD1 User manual

Gigabyte GS-SR 113 User manual

Gigabyte

Gigabyte GS-SR 113 User manual

Popular Server manuals by other brands

Toshiba C1 installation guide

Toshiba

Toshiba C1 installation guide

QSSC QSSC-580 user manual

QSSC

QSSC QSSC-580 user manual

Dell E56S Series Installation and service manual

Dell

Dell E56S Series Installation and service manual

Lenovo System x3500 M5 Type 5464 Installation and service guide

Lenovo

Lenovo System x3500 M5 Type 5464 Installation and service guide

H3C UniServer R2700 G3 user guide

H3C

H3C UniServer R2700 G3 user guide

Supero AS2021M-82R+ user manual

Supero

Supero AS2021M-82R+ user manual

Lenovo ThinkServer RD550 Product guide

Lenovo

Lenovo ThinkServer RD550 Product guide

IBM p5 510 quick start guide

IBM

IBM p5 510 quick start guide

Fujitsu PRIMERGY RX1330 M4 Upgrade and maintenance manual

Fujitsu

Fujitsu PRIMERGY RX1330 M4 Upgrade and maintenance manual

HP D7171A - NetServer - LPr Reference

HP

HP D7171A - NetServer - LPr Reference

Lenovo ThinkServer TD200x Guia del usuario de instalacion

Lenovo

Lenovo ThinkServer TD200x Guia del usuario de instalacion

Polycom RMX 2000 Installation & quick start guide

Polycom

Polycom RMX 2000 Installation & quick start guide

Supero SuperServer 6027PR-HC1R user manual

Supero

Supero SuperServer 6027PR-HC1R user manual

Sprint SPHN240SS manual

Sprint

Sprint SPHN240SS manual

HP ProLiant DL380e user guide

HP

HP ProLiant DL380e user guide

Fujitsu PRIMERGY RX200 S3 Start guide

Fujitsu

Fujitsu PRIMERGY RX200 S3 Start guide

HP HPE iLO 5 user guide

HP

HP HPE iLO 5 user guide

Fujitsu SPARC M10-4 Service manual

Fujitsu

Fujitsu SPARC M10-4 Service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.