Gigaset N720 SPK PRO User manual

Gigaset N720 SPK PRO / LUG ALL en / A31008-XXXXX-XXXX-X-XX / Cover_front.fm / 3/20/20
Version 2, 06.08.2010 / ModuleVersion 1.0
N720 SPK PRO
Multicell System
Site Planning Kit

2
Version 2, 06.08.2010 / ModuleVersion 1.0
Table of Contents
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / Measure_kitIVZ.fm / 3/20/20
Table of Contents
Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Working with the Gigaset N720 SPK PRO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Checking the package contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Further recommended accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Setting up the measuring base station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Starting up the measuring handset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Operating the measuring handset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Customer service and help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Questions and answers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Care. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Contact with liquid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Technical details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

3
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / security.fm / 7/2/20
Version 2, 06.08.2010 / ModuleVersion 1.0
Safety precautions
Safety precautions
Read the safety precautions and the user guide before use.
Comprehensive user guides for all telephones andtelephone systems as well as for accessories
can be found online at gigasetpro.com in the Support category.We thereby help to save paper
while providing fast access to the complete up-to-date documentation at any time.
The device cannot be used in the event of a power failure. In case of a power failure it is also not
possible to make emergency calls.
Emergency numbers cannot be dialled if the keypad/display lock is activated!
Use only rechargeable batteries that correspond to the specification (see list of permitted
batteries www.gigaset.com/service). Never use a conventional (non-rechargeable) battery or
other battery types as this could result in significant health risks and personal injury. Rechargeable
batteries, which are noticeably damaged, must be replaced.
The handset must not be operated if the battery cover is open.
Do not use the devices in environments with a potential explosion hazard (e.g. paint shops).
The devices are not splashproof. For this reason do not install them in a damp environment such
as bathrooms or shower rooms.
Use only the power adapter indicated on the device.
Whilst charging, the power socket must be easily accessible.
Remove faulty devices from use or have them repaired by our Service team, as these could inter-
fere with other wireless services.
Do not use the device if the display is cracked or broken. Broken glass or plastic can cause injury
to hands and face. Send the device to our Service department to be repaired.
Keep small cells and batteries, which can be swallowed, out of the reach of children.
Swallowing a battery can lead to burns, perforation of soft tissue and death. Severe burns can
occur within 2 hours of swallowing.
In the case of a swallowed cell or battery, seek medical care immediately.
Using your telephone may affect nearby medical equipment. Be aware of the technical conditions
in your particular environment, e.g. doctor's surgery. If you use a medical device (e.g. a pace-
maker), please contact the device manufacturer. They will be able to advise you regarding the
susceptibility of the device to external sources of high frequency energy (for the specifications of
your Gigaset product see "Technical data").

4
Version 2, 06.08.2010 / ModuleVersion 1.0
Working with the Gigaset N720 SPK PRO
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / mess_kit.fm / 7/2/20
Working with the Gigaset N720 SPK PRO
The Gigaset N720 SPK PRO (Site Planning Kit) helps you to plan and install your DECT multi-cell
system. It contains one measuring base station, two measuring handsets and further helpful
accessories for exact determination of the DECT environmental conditions for the planned
network, and is delivered in a case.
You can use the measuring devices in the case to determine the DECT
wireless coverage at your location, establish how many base stations are
required and their optimum location and find sources of interferences
in the wireless network.
Checking the package contents
Detailed information on planning a multicell system and performing measurements
to find the optimum positions for the base stations can be found in the Gigaset N870
IP PRO Site Planning and Measurement Guide.
1
4
3
2
5

5
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / mess_kit.fm / 7/2/20
Version 2, 06.08.2010 / ModuleVersion 1.0
Working with the Gigaset N720 SPK PRO
Further recommended accessories
Before you begin
Please note that the measuring devices run on batteries that must be charged before you start
taking measurements. Bear this in mind when planning your time.
You need eight batteries for the measuring base station, provided as a battery pack. The case con-
tains a charging device for charging the battery pack.
The charging time is approximately 3 hours.
You need two batteries for each measuring handset. These can be charged in the chargers and
in standard charging devices. The charging time in the charger is approx. 5 hours.
Stand
To obtain an exact measurement, we recommend that you mount
the measuring base station and battery carrier securely on a stand.
The base carrier is fitted with a thread connection for this purpose.
This enables you to simulate the installation of a base station at every
possible height and check the layout and range of the network.
The stand should have a screw thread and be extendable to a height
of 2.50 to 3.00 m.
Only use rechargeable batteries (P. 18) recommended by Gigaset Communica-
tions GmbH, i.e., never use conventional (non-rechargeable) batteries, otherwise seri-
ous health risks and personal injury cannot be ruled out. For example, the outer cas-
ing of the batteries could be damaged or the batteries could explode. The device
could also malfunction or be damaged as a result of using batteries that are not of the
recommended type.

6
Version 2, 06.08.2010 / ModuleVersion 1.0
Working with the Gigaset N720 SPK PRO
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / mess_kit.fm / 7/2/20
Setting up the measuring base station
To ensure freedom of movement when measuring and not be dependent on being able to reach
a power connection, operate the measuring base station with external batteries. The case
contains a battery pack with eight integrated batteries and one charging device for this purpose.
Preparing the base carrier
Remove the base carrier from the case
together with the measuring base station
and battery pack.
Slide the lid to the left to open the battery
compartment .
Lift the lid gently with your fingernail
to get past the lock on the right edge.
Plug the connector on the battery pack
cable onto the two pins on the left side
of the battery compartment .
Note: The connector is shaped so that it can
only be attached the correct way round. If the
connector is forced into the wrong position,
the pins may be damaged, rendering the
device unusable.
Insert the battery pack into the battery
compartment in the base carrier .
Slide the lid onto the battery compartment
until it clicks into place.
1
1
2
2
3
4
3
4

7
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / mess_kit.fm / 7/2/20
Version 2, 06.08.2010 / ModuleVersion 1.0
Working with the Gigaset N720 SPK PRO
Charging the batteries
The measuring base station is connected
to the power supply by means of
acable .
The charging socket is located behind
opening , while there is a switch for
switching between "Operation" and
"Charge" behind opening .
Move the switch to the charging
position by sliding it towards
the charging socket.
Plug the battery charger into a mains
socket .
You may need to attach the appropri-
ate plug-in module first.
Plug the battery charger plug into
the charging socket on the back
of the base carrier .
Charge the batteries until the charger's
charging indicator lights up.
When the batteries are charged,
unplug the charger plug from the
charging socket and return the
switch to the "Operation" position.
1
2
3
2
1
3
4
5
4
5
The measuring station has sufficient power when the LED
on the front is illuminated.
To save energy, move the switch to "Charge" when you
do not need the device.

8
Version 2, 06.08.2010 / ModuleVersion 1.0
Working with the Gigaset N720 SPK PRO
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / mess_kit.fm / 7/2/20
Alternative power supply
The measuring base station is supplied with power via the battery pack inserted in the battery
carrier. Alternatively, you can also use one of the following power supplies:
Unplug the power cable plug
from the base station.
Connecting to the mains
power supply
Connect the cable for the power
adapter provided to the power
connection on the measuring
base station . Use the power
adapter provided (no. in the
figure on P. 4).
Plug the power adapter into
amainssocket .
1
4
2
21

9
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / mess_kit.fm / 7/2/20
Version 2, 06.08.2010 / ModuleVersion 1.0
Working with the Gigaset N720 SPK PRO
Mounting the measuring base station on the stand
Connecting to a switch with PoE
functionality (Power over Ethernet).
Connect the LAN socket on
the measuring base station
to a connection on an Ethernet
switch .
Use a shielded Ethernet cable.
1
2
1
2
The base carrier is fitted with a bracket for mounting
the measuring base station on a stand.
Position the thread of the battery carrier on the
stand and screw the battery carrier into place.

10
Version 2, 06.08.2010 / ModuleVersion 1.0
Working with the Gigaset N720 SPK PRO
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / mess_kit.fm / 7/2/20
Starting up the measuring handset
Connecting the charger cradle
Inserting the batteries and closing the battery cover
Remove the measuring handsets and
accessories from the case. For each handset
there is:
1 One charging cradle
2Onepoweradapter
3Onebatterycover
4Onebeltclip
5 Four batteries (AAA), of which
two are spares
The display and keypad are protected
by plastic film; please remove it.
12
3 4 5
Connect the flat plug of the power adapter
to the charger .
Insert the power adapter into a mains
socket .
If you have to remove the plug from
the charger cradle again:
Press the release button and
disconnect the plug.
1
2
3
1
2
3
Insert the batteries with the polarity in the
correct direction. The polarity is indicated
in/on the battery compartment.
Insert the battery cover from the top.
Then press the cover until it clicks into place.
To open the battery cover; for example,
to change the batteries:
Insert your fingernail into the notch on the
casing (see arrow), then pull the battery
cover in an upward direction.

11
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / mess_kit.fm / 7/2/20
Version 2, 06.08.2010 / ModuleVersion 1.0
Working with the Gigaset N720 SPK PRO
Initial charging and discharging of the batteries
Battery charging status in the display
The charging status of the battery is shown in the top right
corner of the display:
Connecting a headset to the handset
To assess the quality of the sound transmitted from the measuring station, you can connect
headsets to the measuring handsets.
The correct chargestatus can only be displayed
if the batteries are fully charged and discharged
first.
Charge the handset in the charger
for 5 hours.
After charging, remove the handset from
the charger and only replace it when
the batteries are fully discharged.
The handset may only be placed in the
associated charging cradle.
Lights up white Charged over 66%
Lights up white Charged between 34% and 66%
Lights up white Charged between 11% and 33%
Lights up red Less than 11% charged
Flashes red Battery almost flat (less than 10 minutes of operating time)
Lights up white Battery is charging
The connection for one of the headsets delivered
is on the left side of the measuring handset.
This also means that your hands are free to enter
the locations determined in the plan and you can
read the display during the measurement phase.
The headset volume corresponds to the setting
for the receiver volume.

12
Version 2, 06.08.2010 / ModuleVersion 1.0
Working with the Gigaset N720 SPK PRO
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / mess_kit.fm / 7/2/20
Operating the measuring handset
The measuring handsets
•Switch on automatically when they are placed in the charger
•Are already registered to the measuring base station on delivery
•Are already in metering mode on delivery.
Display in metering mode
In metering mode, the display shows the current status values of the connection to the base station.
The values are updated at brief intervals. You can change this measuring interval (
P. 1 5 ) .
Display in idle mode
The display shows the following information in idle status:
Otherwise the following information is displayed:
You will find detailed information on evaluating the measurement results in the Gigaset N870 IP
PRO Site Planning and Measurement Guide.
This section only describes the functions of the handsets relevant for measurements.
For information on the standard functions of the Gigaset S650H PRO handset, see the
user guide for the device. See the product page at gigasetpro.com.
Values for determining the connection quality:
RSSI value RSSI value. Base station signal reception
strength with the best reception in dBm.
Acceptable value: –20 to -70 dBm.
Units for signal strength P. 1 5 .
Fr. quality Frame quality. Percentage rate of the
packages received without error in the last
measuring interval.
Acceptable value: 95 – 100%
Frequency: 1
Slot pair: 04
RPN: 50 hex
Fr. quality: 100%
Calls
Frequency Frequency. Carrier frequency of the signal received. Value range: 0 – 9.
Slot pair Duplex Slot pair used (0 – 11)
Time slot for the reception channel on which the measurement was performed.
Note: During the transition in the connection status, value 15
is occasionally displayed.
RPN RPN (Radio Fixed Part Number)
ID of the base station to which the handset is connected.The value is displayed
in hexadecimal format.

13
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / mess_kit.fm / 7/2/20
Version 2, 06.08.2010 / ModuleVersion 1.0
Working with the Gigaset N720 SPK PRO
Display not in idle mode
Checking the quality of the connection to the measuring base station
Connecting the measuring handsets
If two people perform the measurements, you can check the voice quality by establishing
a connection between the two measuring handsets.
The handsets are in metering mode in idle status.
Initiate internal call.
Enter the internal number of the other handset using the keypad.
or:
Initiate internal call.
Select handset. Your own handset is identified by a "<" on the right.
Press the talk key.
Calling all handsets
Press and hold.
Switching on the continuous test tone for the base station
If you perform the measurements alone, you can play a continuous test tone to test the connection
to a measuring base station from a measuring handset.
Enterthenumberstring fromthekeypad.
Press the talk key.
The test melody is played via the loudspeaker. If you have connected a headset, press the speaker
key to hear the melody.
Activating/deactivating the measuring handset
The measuring handset is activated automatically when it is placed in the charger. This means
that it is activated after charging in the charger.
With the phone in idle status, press and hold the end call key (confirmation tone)
to deactivate the handset. Press and hold the end call key again to reactivate
the handset.
Switching the handsfree function on/off
You can also test the quality of the connection via the loudspeaker instead of via the headset.
Press the speaker key to switch between earpiece mode and speaker mode.
In this case, place the plastic cover supplied on the headset socket.This improves the quality
in speaker mode.
If the display is not in idle status, it shows the measurement
data at the top edge.
-30dBm-1-04-50H-100

14
Version 2, 06.08.2010 / ModuleVersion 1.0
Working with the Gigaset N720 SPK PRO
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / mess_kit.fm / 7/2/20
Activating/deactivating metering mode
The handset is in metering mode when it is activated.
Exiting metering mode
You exit metering mode by resetting the handset:
System Handset Reset
Reactivating metering mode via the service menu
If you have exited metering mode, you can reactivate it via the service menu. Proceed as follows:
Press and hold the off key to deactivate the handset.
Press , and at the same time and hold them down. Then press
and hold the on key .
The handset is now in Service mode.
Enter the five-digit service PIN. On delivery this is 76200.
The service menu is opened.
Select the Metering Mode entry with
the navigation key.
Change Press the display key to activate the entry.
Once you activate metering mode, the RSSI measurement
menu is opened.
Here you can change the settings for the unit of measure
and the measurement interval.
Metering Mode
Working Time
Apprv. Narr.Band
Apprv. Wide Band
Back Change
Service
SAR

15
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / mess_kit.fm / 7/2/20
Version 2, 06.08.2010 / ModuleVersion 1.0
Working with the Gigaset N720 SPK PRO
Changing the settings for metering mode
In the service menu, you can change the unit of measure and the measurement interval for
metering mode.
Start Press the display key to activate metering mode.
Back Press the display key to exit the service menu again.
The handset is deactivated. When you reactivate it, it is in metering mode with the selected settings.
Metering Mode (unit of measure)
On the display, the signal strength (
RSSI value)
is shown in dBm
as standard. You can also display the signal strength as a per-
centage value. This represents the signal strength of the pack-
age received as a ratio of the maximum possible RSSI (100%).
Use the navigation key to select the desired display
of the signal strength.
dBm
: The signal strength measured is displayed in dBm.
This is preset and is the recommended mode.
%: The signal strength measured is displayed
as a percentage of the maximum possible RSSI
SEN: Not relevant.
Metering range (measurement interval)
The measurement interval defines the time intervals at which
measurements are taken.
Value range: 06 – 16 (1.0 s – 2.5 s)
Recommended value: 16
Use the navigation key to select the required
measurement interval.
Metering Mode:
<dBm
Metering range:
06
Back Change
RSSI measurement
>
Metering Mode:
dBm
Metering range:
< 06
Back Start
RSSI measurement
>
You should not make changes to other settings in the service menu.

16
Version 2, 06.08.2010 / ModuleVersion 1.0
Customer service and help
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / appendix.fm / 3/20/20
Customer service and help
Do you have any questions?
For quick help and information, please refer to this user guide or visit gigasetpro.com.
For online information and services concerning
•Products
•Documents
•Interop
•Firmware
•FAQ
•Support
please refer to wiki.gigasetpro.com.
For further information our Gigaset specialised reseller will be happy to help you related to your
Gigaset product.
Questions and answers
If you have any queries about the use of your telephone, visit our website at
gigasetpro.com.
Environment
Environmental management system
Gigaset Communications GmbH is certified pursuant to the international standards
ISO 14001 and ISO 9001.
ISO 14001 (Environment): Certified since September 2007 by TÜV SÜD Management Service
GmbH.
ISO 9001 (Quality): Certified since 17/02/1994 by TÜV SÜD Management Service GmbH.
Disposal
All electrical and electronic products should be disposed of separately from the municipal waste
stream via designated collection facilities appointed by the government or the local authorities.
This crossed-out wheeled bin symbol on the product means the product is covered
by the European Directive 2012/19/EU.
The correct disposal and separate collection of your old appliance will help prevent
potential negative consequences for the environment and human health. It is a pre-
condition for reuse and recycling of used electrical and electronic equipment.
For more detailed information about disposal of your old appliance, please contact your local
council refuse centre or the original supplier of the product.

17
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / appendix.fm / 3/20/20
Version 2, 06.08.2010 / ModuleVersion 1.0
Appendix
Appendix
Approval
Voice over IP telephony is possible via the LAN interface (IEEE 802.3).
Depending on your telecommunication network interface, an additional router/switch could be
necessary.
For further information please contact your Internet provider.
This device is intended for use worldwide. Use outside the European Economic Area (with the
exception of Switzerland) is subject to national approval.
Country-specific requirements have been taken into consideration.
Hereby, Gigaset Communications GmbH declares that the radio equipment type
Gigaset N720 SPK PRO - Gigaset S650H PRO is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
www.gigaset.com/docs.
This declaration could also be available in the "International Declarations of Conformity" or
"European Declarations of Conformity" files.
Therefore please check all of these files.
Care
Wipe the device with a damp cloth or an antistatic cloth. Do not use solvents or microfibre
cloths.
Never use a dry cloth; this can cause static.
In rare cases, contact with chemical substances can cause changes to the device’s exterior. Due
to the wide variety of chemical products available on the market, it was not possible to test all
substances.
Impairments in high-gloss finishes can be carefully removed using display polishes for mobile
phones.
Contact with liquid
If the device comes into contact with liquid:
1Disconnect the power supply.
2 Allow the liquid to drain from the device.
3 Pat all parts dry.
4 Place the device in a dry, warm place for at least 72 hours (not in a microwave, oven etc.)
with the keypad facing down (if applicable).
5Do not switch on the device again until it is completely dry.
When it has fully dried out, you will normally be able to use it again.

18
Version 2, 06.08.2010 / ModuleVersion 1.0
Appendix
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / appendix.fm / 3/20/20
Technical details
Handset batteries
Each handset is supplied with four recommended batteries.
Operating times/charging times for batteries
The operating time of your Gigaset devices depends on the capacity and age of the batteries and
the way they are used (all times are maximum times).
Battery pack for the measuring base station
Base station mains unit
Technology Nickel metal hydride(NiMH)
Size AAA (Micro, HR03)
Voltage 1.2 V
Capacity 700 mAh
Capacity 2000 mAh
Usage time 5.8 hours
Charging time in charger 3 hours
Manufacturer Salom Electric (Xiamen) Co. Ltd.
Commercial registration number:
91350200612003878C
31 Building, Huli Industrial District,
Xiamen, Fujiam361006, P.R. China
Salcomp (Shenzen) Co. Ltd.
Commercial registration number: 91440300618932635P
Salcomp Road, Furond Industrial Area,
Xinqiao, Shajing, Baoan District, Shenzen 518125 China
Model identifier EU: C557 UK: C608
Input voltage 230 V
Input AC frequency 50 Hz
Output voltage 6,5 V
Output current 0,6 A
Output power 3,9 W
Average active efficiency > 76,1%
Efficiency at low load (10%) not relevant - only at output power > 10 W
No-load power consumption < 0,1 W

19
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / appendix.fm / 3/20/20
Version 2, 06.08.2010 / ModuleVersion 1.0
Appendix
Handset mains unit
Accessories
Ordering Gigaset products
You can order Gigaset products from your specialist retailer.
Spare parts for the Gigaset N720 SPK PRO
Manufacturer Salom Electric (Xiamen) Co. Ltd.
Commercial registration number:
91350200612003878C
31 Building, Huli Industrial District,
Xiamen, Fujiam361006, P.R. China
Salcomp (Shenzen) Co. Ltd.
Commercial registration number: 91440300618932635P
Salcomp Road, Furond Industrial Area,
Xinqiao, Shajing, Baoan District, Shenzen 518125 China
Model identifier EU: C705 UK: C710
Input voltage 230 V
Input AC frequency 50 Hz
Output voltage 4 V
Output current 0,15 A
Output power 0,6 W
Average active efficiency > 46 %
Efficiency at low load (10%) not relevant - only at output power > 10 W
No-load power consumption < 0,10 W
Case with measuring equipment Part number
Gigaset N720 SPK PRO S30852-H2316-R101
Spare part
Measuring base station Gigaset N720 SPK PRO
Base carrier
Battery pack/base station
Charging device/base station
Calibrated Gigaset S650H PRO measuring handset
Headset

20
Version 2, 06.08.2010 / ModuleVersion 1.0
Gigaset N720 SPK PRO / LUG IE-UK_IM en / A31008-XXXXX-XXXX-X-XX / Measure_kitSIX.fm / 3/20/20
Index
A
Approval. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
B
Base carrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
mounting on the stand . . . . . . . . . . . . . . . . . 9
Batteries
charging. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
inserting in handset . . . . . . . . . . . . . . . . . . 10
Battery charge status, handset . . . . . . . . . . . . . 11
Battery charger . . . . . . . . . . . . . . . . . . . . . . . . . 7
Battery compartment cover, handset . . . . . . . . 10
Battery pack
charging. . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
inserting in the base carrier . . . . . . . . . . . . . . 6
Broken display. . . . . . . . . . . . . . . . . . . . . . . . . . 3
C
Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Care of the device . . . . . . . . . . . . . . . . . . . . . . 17
Carrier frequency. . . . . . . . . . . . . . . . . . . . . . . 12
Charging socket . . . . . . . . . . . . . . . . . . . . . . . . 7
Contact with liquid . . . . . . . . . . . . . . . . . . . . . 17
Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Customer service. . . . . . . . . . . . . . . . . . . . . . . 16
D
Display
broken . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
in idle mode . . . . . . . . . . . . . . . . . . . . . . . . 12
in metering mode . . . . . . . . . . . . . . . . . . . . 12
not in idle mode . . . . . . . . . . . . . . . . . . . . . 13
Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
E
Emergency numbers
not possible . . . . . . . . . . . . . . . . . . . . . . . . . 3
Environment . . . . . . . . . . . . . . . . . . . . . . . 16, 19
F
Frame quality . . . . . . . . . . . . . . . . . . . . . . . . . 12
G
Gigaset N720 SPK (Site Planning Kit) . . . . . . . . . . 4
H
Handsfree mode . . . . . . . . . . . . . . . . . . . . . . . 13
Headset
connect . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
L
Liquid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Looking after the phone . . . . . . . . . . . . . . . . . 16
M
Measurement interval . . . . . . . . . . . . . . . . . . . 15
Measuring base station
LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
mounting on the stand . . . . . . . . . . . . . . . . . 9
setting up . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Measuring base station, power supply
via battery pack . . . . . . . . . . . . . . . . . . . . . . 7
via mains power supply. . . . . . . . . . . . . . . . . 8
via PoE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Measuring equipment. . . . . . . . . . . . . . . . . . . . 4
Measuring handset
accessories. . . . . . . . . . . . . . . . . . . . . . . . . 10
activating/deactivating . . . . . . . . . . . . . . . . 13
battery charge status . . . . . . . . . . . . . . . . . 11
charging batteries . . . . . . . . . . . . . . . . . . . 11
connecting . . . . . . . . . . . . . . . . . . . . . . . . 13
connecting charger . . . . . . . . . . . . . . . . . . 10
connecting headset . . . . . . . . . . . . . . . . . . 11
inserting batteries . . . . . . . . . . . . . . . . . . . 10
operating. . . . . . . . . . . . . . . . . . . . . . . . . . 12
starting up . . . . . . . . . . . . . . . . . . . . . . . . . 10
Medical equipment. . . . . . . . . . . . . . . . . . . . . . 3
Metering mode
%. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
dBm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
display. . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
exiting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
reactivating . . . . . . . . . . . . . . . . . . . . . . . . 14
O
Opening the battery compartment . . . . . . . . . . 6
P
Playing test melody. . . . . . . . . . . . . . . . . . . . . 13
PoE (Power over Ethernet) . . . . . . . . . . . . . . . . . 9
Power adapter . . . . . . . . . . . . . . . . . . . . . . . 3, 8
Q
Questions and answers . . . . . . . . . . . . . . . . . . 16
R
Readings
display on handset . . . . . . . . . . . . . . . . . . . 12
RSSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table of contents