Links managed by the RC-001 remote control include the following attributes. These
attributes define the Link characteristics.
1. Radio channel : Specifies the common frequency the radio transmitter in the RC-001
and radio receiver in the fixture are tuned to.
2. Network ID : The Network ID is designed to allow multiple, overlapping pairs of
RC-001/fixtures to work without interference. A common use is to prevent a RC-001
in one apartment or home from affecting a light fixture in another apartment or
home.
3. Device address : Each fixture or fixture controller may be configured with a unique
device address. The RC-001 is configured with the device address for the fixture it
controls.
The factory default configuration for the RC-001 and all LEDlink capable Giulio Lighting
fixtures or fixture controllers contains the same linking attributes allowing a RC-001 remote
control to immediately work with these fixtures.
Certain conditions may require that one of the Link attributes be changed. Example
conditions include the following.
1. The user desires to have multiple RC-001 remote controls, each controlling a
separate fixture.
2. The user desires to change the Radio channel to avoid radio interference from a
microwave oven.
3. The user desires to change the Network ID to avoid interference from a lighting
system in another apartment or home.
The RC-001 contains a built-in mechanism for quickly changing the link to support up to 3
separately addressed fixtures without the use of a computer. This allows up to three separate
RC-001 remote controls to operate in the same environment independently controlling up to
three fixtures or sets of fixtures. This mechanism does not require the use of the utility
program and is described in this section.
For other changes, a utility program, described in chapter “Computer Utility”, is run on a
personal computer connected to the RC-001. The program allows the user to change the
desired Link attribute in the RC-001. Then the RC-001 is disconnected from the computer and
used to transfer the attributes to selected fixtures and fixture controllers by the linking process
described in this section. The linking process configures both the RC-001 and any fixture or
fixture controllers that it is linked to with the same Radio channel, Network ID and Device
address.