• Set the Key switch to Set Limit. The red Fault
LED will light if no limit is set. (In Set Limit &
Inactive modes, the control relay is On to give
free boom movement).
• Set machine to new maximum height limit
position. (Min. 15 degrees above Horizontal).
The Height Limit must be set with the
machine in the ‘worst case’. i.e. equipment at
full reach (for excavators) or extending boom
fully extended (for teletruks and machines
with extending booms).
• Press the Set button and the Yellow LED
comes On. Release the Set button and the
Green LED comes On to indicate a new limit
has been set.
• Set the Key switch to Active. The Red !
LED & Bleep come On as boom is at height
limit. (The control relay goes O to disable
UPWARD movement, if connected).
• Lower the machine boom from the maximum
height.
• The Red ! LED & Bleep go o at about 90%
of the height limit. (The control relay comes
On again to re-enable UPWARD movement, if
connected).
• The Yellow LED goes o at about 70% of the
height limit.
• The Green LED comes on to indicate the
boom is well within the Height Limit.