Installation Guide
WARNING
— To prevent personal injury or product damage only licensed electricians should install.
— To avoid electric shock or component damage disconnect power before attempting installation or servicing.
— This product must be installed in accordance with the national electric code (NEC) and all applicable federal, state and local electric codes and safety standards.
— Disconnect product and allow cooling prior to servicing.
— Any alteration or modification of this product is expressly forbidden as it may cause serious personal injury, death, property damage and/or product malfunction.
— To prevent product malfunction and/or electrical shock this product must be properly grounded.
— RANGE OF POWER ADJUSTMENT IS LIMITED TO 100% / 80% / 60% / 40%. RANGE OF CCT ADJUSTMENT IS LIMITED TO 3000K / 4000K / 5000K.
— This luminaire is designed to operate in ambient temperatures ranging from -40°F to 104°F (-40°C to 40°C).
— This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and
the hazards involved.
— MIN 167°F (75°C) SUPPLY CONDUCTORS.
— Suitable for mounting up to 4ft (1.2m) off the ground.
— If installing product with lens facing up, ensure the lens is kept free of debris to minimize the risk of damage to the product.
— This product is not suitable for several special environments, such as places with corrosive gas liquids or high pressure water vapor.
PLEASE READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION
Installation Guide
1/2"NPS Knuckle Mount (Figure 1)
Trunnion Mount (Figure 2)
OPTIONAL: Ground Stake Mount
1. IMPORTANT: Installation and service of luminaire should only be performed by
a qualified licensed electrician.
2. Install the fixture using the 1/2” screw bracket onto a weatherproof Junction
Box (not included), and secure it using the 1/2” locknut.
3. Make electrical connections from the supply ground (L/N/GND) lead to the
fixture ground (L/N/GND) lead respectively, making sure to follow all National
Electrical code and all applicable codes and ordinances. Make sure water does
not enter the fixture through the 1/2” fitter while making electrical connections.
4. To aim the fixture, loosen the screw on the fitter of the knuckle mount and
rotate the fixture to the desired tilt angle, then retighten the screw.
5. Series GKOFDG11 Flood Lights come equipped with a photocell, which is
covered by a cap by default. To activate the photocell, remove the photocell cap
on the top of the fixture (See Figure 7).
1. IMPORTANT: Installation and service of luminaire should only be performed by
a qualified licensed electrician.
2. Mount the fixture onto the surface using the hole pattern provided on the
trunnion bracket.
3. Make electrical connections from the supply ground (L/N/GND) lead to the
fixture ground (L/N/GND) lead respectively, making sure to follow all National
Electrical code and all applicable codes and ordinances.
4. To aim the fixture, loosen hex socket CM6 screws on the sides of the trunnion
mount and rotate the fixture to the desired tilt angle, then retighten the screws.
5. Series GKOFDG11 Flood Lights come equipped with a photocell, which is
covered by a cap by default. To activate the photocell, remove the photocell cap
on the top of the fixture (See Figure 7).
IMPORTANT: Seal the 1/2" NPS thread using waterproof silicone sealant during
installation to prevent water ingress.
(Figure 1)
Waterproof Ring
15W / 27W
40W / 65W
L
L
N
N
Weatherproof Junction Box
(Not Included)
Silicon Rubber
Waterproof Gasket
1/2" Locknut
6.95 in.
8.33 in.
2.2 in.
2.2 in.
Ø0.35 in.
Ø0.35 in.
Ø0.47 in.
Ø0.47 in.
1.18 in.
1.18 in. 1.18 in.
1.18 in.
1/2" Screw Bracket
Screw
Hex Socket
CM6 Screw
(Figure 2)
10330 Argonne Woods Dr. Ste. 200
Woodridge, IL 60517
Phone: 630-793-9449
Web: www.gkoled.com
Slipfitter Mount (Figure 3)
1. IMPORTANT: Installation and service of luminaire should only be performed by
a qualified licensed electrician.
2. Make electrical connections from the supply ground (L/N/GND) lead to the
fixture ground (L/N/GND) lead respectivelyy, making sure to follow all National
Electrical code and all applicable codes and ordinances.
3. To aim the fixture, remove the cover plate, adjust the bracket to the desired
angle, then replace the cover plate.
4. Install the slipfitter bracket onto the pole and secure it using the M8 Set Screws.
5. Series GKOFDG11 Flood Lights come equipped with a photocell, which is
covered by a cap by default. To activate the photocell, remove the photocell cap
on the top of the fixture (See Figure 7).
Yoke Mount (Figure 4)
Power & CCT Selectable Option (Figure 5 & 6) Photocell Activation (Figure 7)
1. IMPORTANT: Installation and service of luminaire should only be performed by
a qualified licensed electrician.
2. Make electrical connections from the supply ground (L/N/GND) lead to the
fixture ground (L/N/GND) lead respectivelyy, making sure to follow all National
Electrical code and all applicable codes and ordinances.
3. Mount the fixture onto the surface using the hole pattern provided on the
yoke bracket.
4. To aim the fixture, loosen the center bolts and set screws, rotate the fixture to
the desired angle, then tighten the center bolts and set screws.
5. Series GKOFDG11 Flood Lights come equipped with a photocell, which is
covered by a cap by default. To activate the photocell, remove the photocell cap
on the top of the fixture (See Figure 7).
1. To access Power & CCT Adjustment Controls, remove the 1/2” screw plug on
the bottom of the fixture.
2. Use the white switch to set Power and the black switch to set CCT to the
desired settings.
3. Replace the 1/2” screw plug and tighten with a flathead screwdriver.
1. Series GKOFDG11 Flood Lights come equipped
with a photocell, which is covered by a cap by
default. To activate the photocell, remove the
photocell cap on the top of the fixture.
Refer to the diagram below for making
electrical connections.
1. Light does not come ON.
A. Check if the circuit breaker is tripped.
B. Confirm the wall switch is ON.
C. Check if the wiring to the unit is loose.
D. Ensure the fixture is connected to line voltage.
E. Confirm wiring is properly secured.
2. Light cycles ON and OFF continuously.
A. Check if the photocell is sensing reflected light.
3. Light stays ON.
A. Be sure the photocell, if used, is functioning properly.
If the light still does not work after troubleshooting, contact customer service.
Turn off power before continuing..
(Figure 3)
(Figure 4)
(Figure 5) (Figure 6) (Figure 7)
Cover Plate
PM4x12mm Screw
M8 Set Screw
Power Adjustment Switch
(White)
Power Adjustment
Range (40%-100%)
Photocell Cap
Photocell
Black Line
White Neutral
GroundGreen/Yellow Green
100% 5000K
Power CCT
4000K
3000K
80%
60%
40%
CCT Adjustment Range
(3000K | 4000K | 5000K)
CCT Adjustment Switch
(White)
1/2" Screw Plug
Center Bolt
Set Screw
Center Bolt
Bracket
5.43 in.
3.74 in.
2.01 in.
1.97 in.
2-Ø0.87 in. 2-Ø0.43 in.
2-Ø0.55 in.
Power & CCT Dial Switch
Troubleshooting Wiring Diagram
10330 Argonne Woods Dr. Ste. 200
Woodridge, IL 60517
Phone: 630-793-9449
Web: www.gkoled.com

This manual suits for next models

6

Other GKOLED Floodlight manuals

GKOLED GKOFD05 User manual

GKOLED

GKOLED GKOFD05 User manual

GKOLED GKOFD20W120VB-RGBW-WB User manual

GKOLED

GKOLED GKOFD20W120VB-RGBW-WB User manual

GKOLED GKOFD05150W27V50KBDB77 User manual

GKOLED

GKOLED GKOFD05150W27V50KBDB77 User manual

Popular Floodlight manuals by other brands

thomann Stairville Stage Flood Inst QCL 24x10W user manual

thomann

thomann Stairville Stage Flood Inst QCL 24x10W user manual

REV Ritter 0201R Operation and maintenance manual

REV Ritter

REV Ritter 0201R Operation and maintenance manual

Blooma Kenora manual

Blooma

Blooma Kenora manual

Apollo MultiSpot HQ5020 user manual

Apollo

Apollo MultiSpot HQ5020 user manual

NORDRIDE 4310-30 operating instructions

NORDRIDE

NORDRIDE 4310-30 operating instructions

Cameo CLP64RGBA10 user manual

Cameo

Cameo CLP64RGBA10 user manual

ACR Electronics RCL-600A - SCHEMA REV A Product support manual

ACR Electronics

ACR Electronics RCL-600A - SCHEMA REV A Product support manual

Traffic-Manager SY3800110 manual

Traffic-Manager

Traffic-Manager SY3800110 manual

Heitronic 37360 Installation and operating instructions

Heitronic

Heitronic 37360 Installation and operating instructions

Ritos A1D08A1 Operation and maintenance manual

Ritos

Ritos A1D08A1 Operation and maintenance manual

Orion A1 installation guide

Orion

Orion A1 installation guide

Strend Pro AG-HFLAL20W-P-W-Y instruction manual

Strend Pro

Strend Pro AG-HFLAL20W-P-W-Y instruction manual

Sealey LED108C.V2 instructions

Sealey

Sealey LED108C.V2 instructions

Venture Lighting Select-Pro FL58601 user manual

Venture Lighting

Venture Lighting Select-Pro FL58601 user manual

American DJ DJ Flat Par QA5X User instructions

American DJ

American DJ DJ Flat Par QA5X User instructions

LDR Rima A150 operating instructions

LDR

LDR Rima A150 operating instructions

Solena Mini Par 12 user manual

Solena

Solena Mini Par 12 user manual

Cree NTF Series installation instructions

Cree

Cree NTF Series installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.