manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GKOLED
  6. •
  7. Floodlight
  8. •
  9. GKOLED GKOFDG11 Series User manual

GKOLED GKOFDG11 Series User manual

FLOOD LIGHT GKOFDG11
Installation Guide
WARNING
— To prevent personal injury or product damage only licensed electricians should install.
— To avoid electric shock or component damage disconnect power before attempting installation or servicing.
— This product must be installed in accordance with the national electric code (NEC) and all applicable federal, state and local electric codes and safety standards.
— Disconnect product and allow cooling prior to servicing.
— Any alteration or modification of this product is expressly forbidden as it may cause serious personal injury, death, property damage and/or product malfunction.
— To prevent product malfunction and/or electrical shock this product must be properly grounded.
— RANGE OF POWER ADJUSTMENT IS LIMITED TO 100% / 80% / 60% / 40%. RANGE OF CCT ADJUSTMENT IS LIMITED TO 3000K / 4000K / 5000K.
— This luminaire is designed to operate in ambient temperatures ranging from -40°F to 104°F (-40°C to 40°C).
— This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and
the hazards involved.
— MIN 167°F (75°C) SUPPLY CONDUCTORS.
— Suitable for mounting up to 4ft (1.2m) off the ground.
— If installing product with lens facing up, ensure the lens is kept free of debris to minimize the risk of damage to the product.
— This product is not suitable for several special environments, such as places with corrosive gas liquids or high pressure water vapor.
PLEASE READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION
Installation Guide
1/2"NPS Knuckle Mount (Figure 1)
Trunnion Mount (Figure 2)
OPTIONAL: Ground Stake Mount
1. IMPORTANT: Installation and service of luminaire should only be performed by
a qualified licensed electrician.
2. Install the fixture using the 1/2” screw bracket onto a weatherproof Junction
Box (not included), and secure it using the 1/2” locknut.
3. Make electrical connections from the supply ground (L/N/GND) lead to the
fixture ground (L/N/GND) lead respectively, making sure to follow all National
Electrical code and all applicable codes and ordinances. Make sure water does
not enter the fixture through the 1/2” fitter while making electrical connections.
4. To aim the fixture, loosen the screw on the fitter of the knuckle mount and
rotate the fixture to the desired tilt angle, then retighten the screw.
5. Series GKOFDG11 Flood Lights come equipped with a photocell, which is
covered by a cap by default. To activate the photocell, remove the photocell cap
on the top of the fixture (See Figure 7).
1. IMPORTANT: Installation and service of luminaire should only be performed by
a qualified licensed electrician.
2. Mount the fixture onto the surface using the hole pattern provided on the
trunnion bracket.
3. Make electrical connections from the supply ground (L/N/GND) lead to the
fixture ground (L/N/GND) lead respectively, making sure to follow all National
Electrical code and all applicable codes and ordinances.
4. To aim the fixture, loosen hex socket CM6 screws on the sides of the trunnion
mount and rotate the fixture to the desired tilt angle, then retighten the screws.
5. Series GKOFDG11 Flood Lights come equipped with a photocell, which is
covered by a cap by default. To activate the photocell, remove the photocell cap
on the top of the fixture (See Figure 7).
IMPORTANT: Seal the 1/2" NPS thread using waterproof silicone sealant during
installation to prevent water ingress.
(Figure 1)
Waterproof Ring
15W / 27W
40W / 65W
L
L
N
N
Weatherproof Junction Box
(Not Included)
Silicon Rubber
Waterproof Gasket
1/2" Locknut
6.95 in.
8.33 in.
2.2 in.
2.2 in.
Ø0.35 in.
Ø0.35 in.
Ø0.47 in.
Ø0.47 in.
1.18 in.
1.18 in. 1.18 in.
1.18 in.
1/2" Screw Bracket
Screw
Hex Socket
CM6 Screw
(Figure 2)
10330 Argonne Woods Dr. Ste. 200
Woodridge, IL 60517
Phone: 630-793-9449
Web: www.gkoled.com
Slipfitter Mount (Figure 3)
1. IMPORTANT: Installation and service of luminaire should only be performed by
a qualified licensed electrician.
2. Make electrical connections from the supply ground (L/N/GND) lead to the
fixture ground (L/N/GND) lead respectivelyy, making sure to follow all National
Electrical code and all applicable codes and ordinances.
3. To aim the fixture, remove the cover plate, adjust the bracket to the desired
angle, then replace the cover plate.
4. Install the slipfitter bracket onto the pole and secure it using the M8 Set Screws.
5. Series GKOFDG11 Flood Lights come equipped with a photocell, which is
covered by a cap by default. To activate the photocell, remove the photocell cap
on the top of the fixture (See Figure 7).
Yoke Mount (Figure 4)
Power & CCT Selectable Option (Figure 5 & 6) Photocell Activation (Figure 7)
1. IMPORTANT: Installation and service of luminaire should only be performed by
a qualified licensed electrician.
2. Make electrical connections from the supply ground (L/N/GND) lead to the
fixture ground (L/N/GND) lead respectivelyy, making sure to follow all National
Electrical code and all applicable codes and ordinances.
3. Mount the fixture onto the surface using the hole pattern provided on the
yoke bracket.
4. To aim the fixture, loosen the center bolts and set screws, rotate the fixture to
the desired angle, then tighten the center bolts and set screws.
5. Series GKOFDG11 Flood Lights come equipped with a photocell, which is
covered by a cap by default. To activate the photocell, remove the photocell cap
on the top of the fixture (See Figure 7).
1. To access Power & CCT Adjustment Controls, remove the 1/2” screw plug on
the bottom of the fixture.
2. Use the white switch to set Power and the black switch to set CCT to the
desired settings.
3. Replace the 1/2” screw plug and tighten with a flathead screwdriver.
1. Series GKOFDG11 Flood Lights come equipped
with a photocell, which is covered by a cap by
default. To activate the photocell, remove the
photocell cap on the top of the fixture.
Refer to the diagram below for making
electrical connections.
1. Light does not come ON.
A. Check if the circuit breaker is tripped.
B. Confirm the wall switch is ON.
C. Check if the wiring to the unit is loose.
D. Ensure the fixture is connected to line voltage.
E. Confirm wiring is properly secured.
2. Light cycles ON and OFF continuously.
A. Check if the photocell is sensing reflected light.
3. Light stays ON.
A. Be sure the photocell, if used, is functioning properly.
If the light still does not work after troubleshooting, contact customer service.
Turn off power before continuing..
(Figure 3)
(Figure 4)
(Figure 5) (Figure 6) (Figure 7)
Cover Plate
PM4x12mm Screw
M8 Set Screw
Power Adjustment Switch
(White)
Power Adjustment
Range (40%-100%)
Photocell Cap
Photocell
Black Line
White Neutral
GroundGreen/Yellow Green
100% 5000K
Power CCT
4000K
3000K
80%
60%
40%
CCT Adjustment Range
(3000K | 4000K | 5000K)
CCT Adjustment Switch
(White)
1/2" Screw Plug
Center Bolt
Set Screw
Center Bolt
Bracket
5.43 in.
3.74 in.
2.01 in.
1.97 in.
2-Ø0.87 in. 2-Ø0.43 in.
2-Ø0.55 in.
Power & CCT Dial Switch
Troubleshooting Wiring Diagram
10330 Argonne Woods Dr. Ste. 200
Woodridge, IL 60517
Phone: 630-793-9449
Web: www.gkoled.com

This manual suits for next models

6

Other GKOLED Floodlight manuals

GKOLED GKOFD05150W27V50KBDB77 User manual

GKOLED

GKOLED GKOFD05150W27V50KBDB77 User manual

GKOLED GKOFD20W120VB-RGBW-WB User manual

GKOLED

GKOLED GKOFD20W120VB-RGBW-WB User manual

GKOLED GKOFD05 User manual

GKOLED

GKOLED GKOFD05 User manual

Popular Floodlight manuals by other brands

Chauvet Intimidator Spot 255 IRC user manual

Chauvet

Chauvet Intimidator Spot 255 IRC user manual

Chroma Color Charge Plus quick start guide

Chroma

Chroma Color Charge Plus quick start guide

ShowPro HEX36 user manual

ShowPro

ShowPro HEX36 user manual

Phottix PPL-200 manual

Phottix

Phottix PPL-200 manual

Elation DLED Par Zoom instruction manual

Elation

Elation DLED Par Zoom instruction manual

Cooper Wheelock XB15 specification

Cooper Wheelock

Cooper Wheelock XB15 specification

mbt Lighting LEDWPAR64 user manual

mbt Lighting

mbt Lighting LEDWPAR64 user manual

Griven GRAPHITE MK2 2000 AD3754 instruction manual

Griven

Griven GRAPHITE MK2 2000 AD3754 instruction manual

Robe Robin square user manual

Robe

Robe Robin square user manual

Francis Searchlights A2213 User instruction & installation manual

Francis Searchlights

Francis Searchlights A2213 User instruction & installation manual

BEGA 84 530 Installation and technical information

BEGA

BEGA 84 530 Installation and technical information

GLP Impression X4 XL instruction manual

GLP

GLP Impression X4 XL instruction manual

ADJ Festive LED Pak User instructions

ADJ

ADJ Festive LED Pak User instructions

Griven GR0570 HMI 2500 W instruction manual

Griven

Griven GR0570 HMI 2500 W instruction manual

EuroLite LED KLS Scan Next FX user manual

EuroLite

EuroLite LED KLS Scan Next FX user manual

GoodHome AWL1022-NB manual

GoodHome

GoodHome AWL1022-NB manual

GEV LPL 14817 user manual

GEV

GEV LPL 14817 user manual

Intermatic Malibu CL509 instructions

Intermatic

Intermatic Malibu CL509 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.