you'll have to use
a stipulated safety wire. Attach the safety wire through one of the two holes
provided on the base of the fixture and connect it to the primary support
structure. Pay attention to a safe and proper fastening. The safety cable must
comply with BGI 810-3 (EN 60598-2-17 Section 17.6.6) and be capable of
bearing a static suspended load that is ten times the weight of the fixture and all
installed accessories.
3.3 Connections
3.3.1 Power Supply
~100-240 Volt AC, 50-60 Hz, powerCON AC connector
Connected load 85 VA (W) T2A (micro-fuse 5x20mm)
Please also see the printing on the case!
Disconnect from the mains supply for changing the fuse and use only
the above described micro-fuse type.
3.3.2 NEUTRIK
powerCON
The IMPRESSION X1 is fitted with NEUTRIKpowerCON locking 3
conductor AC connectors.
The grey connector must be used to draw AC mains power from the fixtures`
throughput sockets and the blue connectors must be used to supply power at
the fixtures` power input socket.
The total number of fixtures in one interconnected chain depends on your local
AC mains voltage but you must never connect more than a total load of 20A to
stay within the limits of the connector. The total load includes all connected
fixtures including the first one in the chain.
Note: The maximum allowed total -
load is 20A including the first fixture
in one interconnected daisy chain.