Goddess Bibione 1 User manual

Bibione 1 / Bibione 1 ION / Korsika 1 / Korsika 1 ION
Costa Brava 2 / Costa Brava 2 ION / Mallorca 2
Mallorca 2 ION / Mallorca 2 CE ION / Chalkidiki 2
Chalkidiki 2 ION / Tenerife 3 / Tenerife 3 ION
NÁVOD K POUŽITÍ
NÁVOD NA POUŽITIE
INSTRUCTION MANUAL
Osobní infra
sauna
Osobnná infra
sauna
Personal infra
sauna

ENG
ENG - 28
Thank you for choosing our infrared sauna!
INDEX
Important safety guides ......................................................................................................... 29
Introduction, benets, highlights ............................................................................................ 30
Installation requirements ....................................................................................................... 31
Installation procedure ............................................................................................................ 31
Operation ............................................................................................................................... 36
Warnings ............................................................................................................................... 37
Trouble Shooting ................................................................................................................... 37
Maintenance .......................................................................................................................... 39
Transportation ....................................................................................................................... 39
Packing List ........................................................................................................................... 39

ENG
ENG - 29
IMPORTANT SAFETY GUIDES
READ AND FOLLOW ALL INSTRUCTIONS
A) A receptacle shall not be installed inside the heated room.
B) The door of the heated room do not include any locking or latching system,
malfunction of which could cause entrapment inside the heated room.
C) Keep the intended ventilation open when use the dry-bath bathing room.
D) CAUTION – Hyperthermia occurs when the internal temperature of the body reaches a level
several degrees above the normal body temperature of 98.6°F (37°C). The symptoms
of hyperthermia include an increase in the internal temperature of the body, dizziness,
lethargy, drowsiness, and fainting. The effects of hyperthermia include:
a) Failure to perceive heat;
b) Failure to recognize the need to exit the room;
c) Unawareness of impending hazard;
d) Fetal damage in pregnant women;
e) Physical inability to exit the room; and
f) Unconsciousness.
WARNING – The use of alcohol, drugs, or medication is capable of greatly increasing
the risk of fatal hyperthermia.
E) CAUTION – if the manually resettable temperature-limiting control trips frequently,
a qualied serviceman should be contacted.
F) WARNING – reduce the risk of electrocution and burns, do not operate unless guard is
in place.
G) CAUTION – excessive exposure can be harmful to health. Persons with poor health should
consult their physicians before using sauna.
H) CAUTION – reduce the rick of re, do not place combustible material on heater at any time.
I) Don´t take water or the other liquids into the sauna room, in order to prevent the injury from
the electric current.
J) WARNING – reduce the risk of overheating:
a) exit immediately if uncomfortable, dizzy, or sleepy, staying too long in a heated area is
capable of causing overheating.
b) supervise children at all times.
c) check with a doctor before use if pregnant, in poor health, or under medical care.
d) breathing heated air in conjunction with consumption of alcohol, drugs, or medication is
capable of causing unconsciousness.
K) WARNING – reduce the risk of electrocution, disconnect the supply connect before
servicing.
Save these Instructions

ENG
ENG - 30
INTRODUCTION
We welcomes you to the most affordable infrared sauna in the nation! We also congratulate
you on your new path to better health! Thousands of users enjoy the benets of infrared saunas
every day. Infrared saunas help you burn calories, reduce toxins, relieve pain and even clear
complexions. Now you can enjoy the great benets of far-infrared heat within the privacy of your
own home.
We strives to deliver superior ttness products at an affordable price. Our list of clients grows
daily and we believe that your success is our success. Our staff is ready to provide you with
excellent customer service.
HEALTH & BEAUTY BENEFITS
Relieve pain:
The far-infrared rays of a sauna accelerate the blood circulation and supply more oxygen to
the body. Increased blood circulation diminishes inammation, relieves pain, and speeds up
recovery. Infrared saunas have also been used to treat bursitis, rheumatism, arthritis,
and hemorrhoids. Increased blood circulation not only alleviates internal ailments, but also skin
conditions such as psoriasis, eczema and scars. Good circulation is essential for smooth
and rm skin.
Burn calories & fat:
The far-infrared rays of the sauna eliminate extra salt and subcutaneous fat. Burn up to 600
calories in one half hour session versus a half hour of jogging which burns 300 calories,
and a half hour of cycling burns 225 calories.
Relax your body and mind:
It supplies you for a special environment with 30˚C - 65˚C. The far infrared wave pass through
your body, speed the metabolism, accelerate the blood circulation, bring the fresh oxygen
and nutriment into the organization, the rubbish expel from body along with the sweat, renew
the energy quickly, then relieve tiredness. When enjoying the wave, you can listen to
the music in CD , it can relax your body .Besides, far infrared sauna can cure the insomnia,
and other other stress related disorders.
HIGHLIGHTS
A) High quality craftsmanship
B) Automatic thermostat for constant temperature
C) Timer and buzzer: buzzer sounds 5 minutes before the end of session
D) Digital sensor and thermometer
E) Infrared heating pipes
F) FM radio and AUX input for connecting MP3 player / mobile phone
(stereo connection cable included)
Ionizer - by a large number of negatively charged ions (anions) refreshes the air, cleans it
from smoke, dust, pollen from flowers and other debris, kills bacteria and viruses.
(only for models with Ionizer: Bibione 1 ION / Korsika 1 ION / Mallorca 2 ION
/ Mallorca 2 CE ION / Costa Brava 2 ION / Chalkidiki 2 ION / Tenerife 3 ION)

ENG
ENG - 31
INSTALLATION
INSTALLATION REQUIREMENTS
A) Do not plug any other appliances into the outlet with your our infrared sauna.
(The outlet must be secured by current-balance protection)
B) Install the sauna on a completely level oor.
C) Do not spray the exterior with water. Keep the sauna installed in a high & dry place.
D) Do not store ammable objects or chemical substances near the sauna.
INSTALLATION PROCEDURE
SAUNA ROOM:
1) Structure of Infrared Sauna. See FIG-1 (ollustrative picture - differs as per the model NO.)
1) front board
2) bottom board
3) sitting baffle
4) bench
5) right side board
6) Fever board
7) internal top board
8) external top board
9) electric control box
10) left side board
11) digital panel
2) One person and 2 person unit are packed into two cartons. See FIG-2
FIG-2 Two cartons
3-persons sauna, corner sauna and 4-persons sauna are packed in 3 cartons

ENG
ENG - 32
3) Make sure all parts are present before installing the unit. See packing list below.
4) Place the bottom board (section 4, Sauna room diagram, p.3) in the desired location of your
sauna, and make sure which side is the front and which side is the back. See FIG-3.
FIG-3 Placing bottom oor FIG-4 Assembling back board
5) Align the backboard with bottom board’s corresponding battens; make sure they are in line.
See FIG-4.
6) Align the left board with bottom board’s corresponding battens; make sure left board ts
ush into backboard. See FIG-5.
FIG-5 Assembling left board FIG-6 Latching
7) The latch has a guide tab that must be placed in the guide slot for alignment. Pick up the
back panel (hold it upright to the oor panel) and place the tab in the slot, do not latch at this
time. When the back wall and the front wall/side wall are set together on the oor panel,
close and latch it. See FIG-6.

ENG
ENG - 33
8) Align the right board with bottom board’s corresponding battens; make sure right board ts
ush into backboard and latch together. See FIG-7.
FIG-7 Assembling right board FIG-8 Assembling sitting board
9) Put the sitting board horizontally on corresponding battens of the backboard. See FIG-8.
FIG-9 Assembling front board FIG-10 Setting the top board
10) Align the front board (section 3) with bottom board’s corresponding battens, and then latch
it with the left and right boards respectively. Notes: Take caution of the glass door to avoid
damage. See FIG-9.
11) Put the wires of front board and backboard into the cabinet to avoid pressing the wires
during installing. See FIG-10. Open the door, raise the top board high enough to see if it ts
with the surrounding boards, then put down.
FIG-11 Leading the wires of heaters
onto the board through the corresponding hole
12) During the course of putting down the internal top board, make sure all the wires (mentioned
above) and connecting plugs are slipped through the corresponding holes of the top board.
All these wires will be led into connecting with the controller on the internal top board.
See FIG-11.

ENG
ENG - 34
13) See FIG-12. Connect all the wires and connectors to the corresponding outlets on the top
board. Please be sure all the plugs are connected tightly.
FIG-12 Connectors on the FIG-13 Antenna connectors
internal top board
14) Install the ionizer
(Note: Insert the ionizer to the prepared frame from the top side and connect the power
connector). See FIG-14.
FIG-14 Install the ionizer
15) Making sure all steps are nished correctly, plug in the power and try using the sauna at rst
to make sure it will work properly. Then put the external top board (section 10) over the
internal top board, and take out the power plug through the corresponding hole in the
external top board. See FIG-15.
FIG-15 Slip the power plug FIG-16 Fix the external
through external top board board with screws
16) Take the screws afxed on the external top board, then set up the board using the cross
screwdriver. See FIG-16.
Installation Completed.

ENG
ENG - 35
OPERATION
1) Precautions
a) Check all the circuitry and the plug meet all requirements.
b) Set the temperature and time to a comfortable level, normally, 60 minutes at
50-65ºC (122ºF-140ºF)
Note: If ambient temperature is lower than 18.3ºC (65ºF), please set the temperature at
about 122ºF (50ºC); and if ambient temperature is higher than 18.3ºC (65ºF), please set
the temperature at about 65ºC (140ºF).
c) Drink a cup of water before the sauna session.
d) After 2 hours of continuous use, shut the sauna down for one hour.
e) To avoid burns, do not touch the heating element.
2) Operation
a) plug the sauna into a wall outlet (220V-240 Volt) which is stated in nameplate.
Do not share the outlet with any other appliances.
Switch on the main switch at the ceiling of the sauna room and then activate the sauna
through the ON/OFF switch on the control panel.
Sauna should be unplugged when not in use.
b) Press the ‘temperature’ button ▲,▼ to increase or decrease the temperature. Every
time the “▲“ button is pushed. If pressed for three seconds, the setting will increase
quickly. Decrease the temperature in the same manner by pressing the “▼“ button.
After the sauna reaches the desired temperature, the “heat“ light turns off.
c) Press the ‘time’ button ▲,▼ to set the using time. The same operation as b.
When the display time is “05”,the buzzer will clew 1 minute.
d) Press the ‘light’ button to turn the interior light on and off.
e) After your sauna session, turn off, and unplug the power cable.
f ) To set the time press the “function“ button until the ‘time” button blinks. Press the “+“ and
“-“ buttons to set the timer from 5 to 60 minutes. If pressed for three seconds, the timer
will increase quickly. When the display reads “05“, the timer will buzzes then the
machine will shut off automatically after 5 minutes. To extend the sauna session, reset
the timer again.
g) The Fahrenheit and Centigrade display can be switched: press the temperature button “+“
and “-“ at the meantime, then press the button of „light“ to switch
h) If you want to activate (or deactivate) the ionizer, you can do it any time during the sauna
process by switching the ON (OFF) button on the ionizer.

ENG
ENG - 36
3) Music playback
1) Plug in the socket for the sauna and Press Music button to start ,Temperature display
shows AU means AUX function,shows XXX XO means radio,When it is in radio mode.
Control panel will display frequency from (86.00-108.00).
2) Press TEMP/FM button to change the frequency . Press it for 1.5 seconds,
it will decrease or increase automatically until received radio; Press it more than
2 seconds ,It can search radio cyclically after listening the beep .It will stop one second
when received radio ,at the same time you can press any “frequency” button or “voice”
button to stop searching radio.
3) Press TIME/VOL button to decrease or increase voice .Control panel will display “UL”,
you can change.
The voice from “00”to“15”, “00” indicates mute and “15” indicates maximum.
4) The voice and radio can be storage automatically .It can recover previous radio
and voice next time.
5) Control panel will display temperature and time if there is no operation for 15 seconds
(when sauna is working) .
6) It can change to Music operation by pressing “ Music ” button when it under sauna room
working mode ,and the “Music” button will twinkle.
7) Press “Music” button to AUX .Plug into AUX input and you will receive signal from AUX.
Please turn off the AUX input when not in use.
8) Press “Music” button long time, The temperature display can change from“n1”and“n2”.
“n1”:Adjust frequency with 100 KHz ; “n2”: Adjust frequency with 50 KHz .

ENG
ENG - 37
WARNINGS
Safety precautions
A) To avoid fire, do not dry clothes or leave any towels in the sauna.
B) To prevent burns or electric shocks, do not touch or use metal tools on the net cover
of the far infrared heater elements.
C) While in the sauna, do not touch the light bulb. If the bulb needs to be changed,
switch it off and wait until the sauna is shut off and the bulb is cool
D) Do not spray water on the far-infrared tube. This activity may result in electric shock
or damage to the heater elements.
E) Do not use the infrared sauna if you have any of the following conditions:
1) Open wounds
2) Eye diseases
3) Sever sunburns
4) Elderly & weak people, especially those suffering from a disease, pregnant women
and infants are prohibited. Children over the age of 6 years may use the sauna under
the supervision of adults.
5) If suffering from a disease directly related to temperature, seek the advice of a doctor before
using.
F) Do not place pets in the sauna.
G) Do not use the sauna if you are under the effects of alcohol.
H) Do not take wather or the liquids into the sauna room.
TROUBLE SHOOTING:
Problem Possible reason Countermeasure
Indicator light for power
supply not working
The connector is not con-
nected properly
Check the connector or replace
a new one
No power supply input
Check the circuitry (especially
weather there is power supply
input)
Indicator light is broken Replace the circuitry panel
Indicator light for function
is not working
The heating indicator light is
broken Replace the relevant control panel
The circuit board
or components are broken Replace the circuit board
The temperature sensor is
broken
Check the connect is loosen
and replace it
Infrared Heater
not heating up
The heater is broken Replace with a new one
Of the same specications
The wire junction
or the heater’s wire is loosen Check and make them tight
The temperature sensor
is broken
Check junction of the temperature
sensor is loosen and replace it
The circuit board of the relay
is not work Replace the circuit board

ENG
ENG - 38
Odor from the sauna The circuit‘s problems
1) There is eyewinker around,
remove it
2) Some heater’s temperature
over high,cut off the power
supply,replace it
3) Parts on the circurity is broken
Light bulb is not working
Light bulb is burned out Replace the light bulb
Light bulb wiring is loosen Replace the lamp holder
Problems with electrical cont-
rol panel Repair or replace it
Speaker does not work
The speaker is broken Replace with a new one
of the same specications
The speaker wire is loosen Reconnect the speaker wire
The connecting cable from
the MP3 player / phone is
broken or loose.
Check or replace the cable.
Sauna is not power up
Power cord is unplug Plug back power cord to outlet
Outlet has no power Check outlet or circuit breaker
Power supply or circuit panel
is broken
Replace the power supply or rela-
ted circuitry board
The temperature display
show „EP“
The connector
of temperature sensor is loose
or sensor damaged
Tighten the connector
of temperature sensor or change
to a new temperature sensor.
The temperature display
show „H“
The temperature inside the
sauna room is too high
Turn off the unit, and contact
the manufacture.
The temperature display
show „00“,
and the temperature on
the display is lower than
5˚C after 5 minutes.
some of heaters don‘t work Check whether all heaters are
working, change to new heater

ENG
ENG - 39
USER MAINTENANCE INSTRUCTIONS
CLEAR AND MAINTENANCE
Cleaning
Clean the faceplate with a wet towel, or clean with a small amount of hand-soap mixed with
warm water if necessary. Clean the sauna room with a wet cotton towel, dry with a clean dry
towel.
Do no use benzene, alcohol, or strong cleaning chemicals on sauna.
NOTE: Any chemical that can damage wood material will damage the sauna
and the protection layer that is on the wood.
Suggest: do not leave the sauna on for more than 2 hours at a time.
(For giving heaters longer lifetime.)
TRANSPORTATION AND STORAGE
1) Avoid exposure to rain, snow or strong collisions during transport.
2) Do not store in damp environments.
PACKING LIST
1X front panel
1X backboard
2X side panels
1X oor panel
1X inner top panel
1X outer top panel
1X sitting panel
1X set of heating elements
1X set of bulbs (quantity according to the sauna model)
2X Speakers
1X Bag of screws and bolts
1X Instruction manual
1X Ionizer (only for models with Ionizer: Bibione 1 ION / Korsika 1 ION
/ Mallorca 2 ION / Mallorca 2 CE ION / Costa Brava 2 ION / Chalkidiki 2 ION
/ Tenerife 3 ION)

ENG
ENG - 40
We reserve the right to change technical specifications.
WARNING: Do not use this product near water, in wet areas to avoid re or injury
of electric current. Always turn off the product when you don’t use it or before
a revision. There aren’t any parts in this appliance which are reparable by consumer.
Always appeal to a qualied authorized service. The product is under a dangerous
atention.
Old electrical appliances, used batteries and accumulators disposal
This symbol appearing on the product, on the product accessories or on
the product packing means that the product must not be disposed as household
waste. When the product/ battery durability is over, please, deliver the product
or battery (if it is enclosed) to the respective collection point, where the electrical
appliances or batteries will be recycled. The places, where the used electrical
appliances are collected, exist in the European Union and in other European
countries as well. By proper disposal of the product you can prevent possible
negative impact on environment and human health, which might otherwise occur as
a consequence of improper manipulation with the product or battery/ accumulator. Recycling of
materials contributes to protection of natural resources. Therefore, please, do not throw the old
electrical appliances and batteries/ accumulators in the household waste. Information, where
it is possible to leave the old electrical appliances for free, is provided at your local authority,
at the store where you have bought the product. Information, where you can leave the batteries
and accumulators for free, is provided to you at the store, at your local authority.

WARRANTY CARD
GUARANTEE
The device supplied by our Company is covered by a 24 month guarantee starting
on the date of purchase (receipt). During the life of the guarantee any fault of the device
or its accessories ascribable to material or manufacturing defects will be eliminated free of
charge by repairing or, at our discretion, by replacing it. Proof of the guarantee is
provided by the proof of purchase. Without proof of purchase no free replacement
or repair will be carried out.
If you wish to make a claim under the guarantee please return the entire machine
in the original packaging to your dealer together with the receipt.
The guarantee lapses:
-in case of unauthorized tampering
-destroyed unit by natural disaster
-any changes in guarantee list by unauthorized person
-using this machine for other purpose that usual, especially for professional or other
commercial use
-with apparent mechanic defects
The guarantee does not apply on goods damaged due to unusual usage.
The damage of accessories is not an automatic reason for replacing the entire device free
of charge.
The manufacturer reserves the right to make minute changes to the standard model that
will have no effect on functionality of the product.
This device has been tested according to all relevant current CE guidelines, such as
electromagnetic compatibility and low voltage directives, and has been constructed
in accordance with the latest safety regulations.
After the expiry of the guarantee
After the expiry of the guarantee repairs can be carried by the competent dealer or repair
by the authorized service.
C
ENG
Match code: Bibione 1 / Bibione 1 ION / Korsika 1 / Korsika 1 ION Costa Brava 2 / Costa Brava 2 ION
Mallorca 2 / Mallorca 2 ION / Malorca 2 CE ION / Chalkidiki 2 / Chalkidiki 2 ION / Tenerife 3
Tenerife 3 ION
Date of sale: Serial number:
Seller and signature:

This manual suits for next models
12
Table of contents
Other Goddess Plumbing Product manuals
Popular Plumbing Product manuals by other brands

baliv
baliv WT-300 manual

T&S
T&S B-0679 Installation and maintenance instructions

Helvex
Helvex URM-22 installation guide

Hans Grohe
Hans Grohe Raindance Select S 240 2jet 26470000 Instructions for use/assembly instructions

noken
noken City 100090014 Installation and Maintenance

Allen + Roth
Allen + Roth 58101-X607011 quick start guide

CRISTINA
CRISTINA SX602 installation instructions

Dynamic
Dynamic DYN-6336-02 owner's manual

American Standard
American Standard COLONY SOFT 4175.500 installation instructions

Kohler
Kohler ODEON 98963M-4 installation instructions

Brizo
Brizo RP6949570 quick start guide

Kohler
Kohler K-7147T installation instructions