Gooxi RMC3116-670-HS User manual

RMC3116-670-HS
User Manual
Version 1.0

Shenzhen Gooxi Hengyu Technology Co., Ltd
Content
Manual Structure
Foreword
Chapter 1 Chassis Overview
Chapter 2 Easy Installation Instruction
Chapter 3 Chassis Parameters

Shenzhen Gooxi Hengyu Technology Co., Ltd
Foreword
This manual is about the installation and use information of RMC3116-670-HS
chassis that provided to professional system integrators and personal computer
technicians. The installation and maintenance should be conducted by experienced
technicians only.
Gooxi RMC3116-670-HS the fourth generation of server chassis is designed
based on standard 2U server and can be assembled into common computing server,
storage server, Internet bar server, database server, VOD storage server, HPC server,
and so on. The server chassis is different from ordinary desktop chassis that pays
more attention to appearance design, as it focuses on the quality and content. Gooxi
RMC3116-670-HS server chassis uses imported first-class SGCC galvanized steel,
and possessed with the characteristics of fingerprint resistance, corrosion resistance,
heat resistance, heat transfer and thermal reflectivity, formability as well as
weldability.
In addition, taking into account the higher stability requirements of the server
during usage, Gooxi RMC3116-670-HS server chassis has excellent heat dispersion.
To be specific, the heat dissipation channel is reasonably designed, which can take
away a large amount of heat in the chassis to ensure the stable operation of the server.
The scalability is an important factor to determine whether the server chassis
design is reasonable. Gooxi RMC3116-670-HS server chassis has stronger scalability
than ordinary chassis, such as: hard disk expansion, peripheral expansion, etc.

Shenzhen Gooxi Hengyu Technology Co., Ltd
Chapter 1 Chassis Overview
1.1 Chassis Structure
(1)Top cover
(2)Rear window
(3)Front cover
(4)Fan
(5)Hard disk module
(6)Power supply
(7)3.5-inch hard disk box
(8)Left-side ear
(9)Right-side ear

Shenzhen Gooxi Hengyu Technology Co., Ltd
1.2 Rear Window Construction
①Power site
②I/O washer position
③Expansion slot
1.3 Materials Package
64 pieces of #6-32*5mm countersunk screws are used for fixing hard disks.
10 pieces of active studs with the total height of 8mm are used to install the
motherboard.
16 pieces of #6-32*6mm cross recessed pan head
screws are used for fastening the motherboard and
power supply.
0~15 SAS - label.
One 100 * 120 * 0.045mm PE valve bag.
1.4 Chassis View
Front view:

Shenzhen Gooxi Hengyu Technology Co., Ltd
Rear view:
1.5 Related Indicators of Chassis Panel

Shenzhen Gooxi Hengyu Technology Co., Ltd
The above picture shows the front panel buttons and LED indicators; each button
or indicator light has its own function and status description that are described in the
following table:
LED Status Description
No.
Picture
LED Appearance
Description
1
-
LOGO label (labeling or
customized acrylic label)
②
The green light is on
The device is on
③
Reset
The button is used to restart
the server
④
The green light
flashes
The system is running
normally
⑤
The yellow light is
on
Alarm indication,
including system alarm, fan
alarm, power alarm, etc.; the
specific can be viewed
through IPMI management
software
⑥
The green light is on
Internet access 1 connection
is normal
⑦
The green light is on
Internet access 2 connection
is normal
⑧
USB interface
2*USB2.0 interface

Shenzhen Gooxi Hengyu Technology Co., Ltd
1.6 Introduction to Hard Disk Indicator
1、Act LED
2、FaultLED
3、StatusLED
4、LED description is as follows:
Function
Act LED
Fault LED
Status LED
Hard disk at
site
ON
OFF
OFF
Hard disk
activity
Flash 4Hz/s
OFF
OFF
Hard disk
location
ON
Flash 4Hz/s
OFF
Hard disk
fault
ON
OFF
ON
RAID
reconstruction
ON
OFF
Flash 1Hz/s
1.7 Brief Introduction to Backplane
The standard configuration of Gooxi backplane model is RMC3116-BP-12G, and
the specific description is as follows:
ActLED
Fault LED
StatusLED

Shenzhen Gooxi Hengyu Technology Co., Ltd
RMC3116-BP-12G
Correspon
ding site
Interface / jumper /
slot
Corresponding
site
Interface / jumper / slot
1、2、3、4
4 ATX power input
9、10、11、12
SFF-8643 12Gb SAS input
interface
5、6、7、8
4 Sockets of 4PIN
temperature control fans
1.8 Introduction to the Output Interface of Backplane Hard Disk

Shenzhen Gooxi Hengyu Technology Co., Ltd
Chapter 2 Easy Installation Instruction
2.1 Introduction to the Disassemble Steps of Gooxi 3116 Chassis Cover
⑴Unscrew the top cover screws

Shenzhen Gooxi Hengyu Technology Co., Ltd
⑵Press the button of chassis back cover
⑶Push the back cover
(4) Pull the back cover
2.2 Introduction to the Installation Steps of Gooxi3116 Chassis Fan Module
⑴Install the hot-swappable fan modules into the chassis, respectively.
(1) Finished completion effect of fan module.

Shenzhen Gooxi Hengyu Technology Co., Ltd
(2) Finished completion effect of the last three fan modules.

Shenzhen Gooxi Hengyu Technology Co., Ltd
2.3 Introduction to the Insert and Plug Steps of Gooxi3116 Chassis Hard Disk
⑴Press the button to pull out the hard disk from the hard disk site.
(2)Install the 3.5-inch hard drive to the hard drive bracket according to screw holes, as
shown in the figure below.

Shenzhen Gooxi Hengyu Technology Co., Ltd
(3) The installed hard disk is shown in the following figure:
(4) Insert hard disk to the chassis, and close the switch. As shown in the following
figure.

Shenzhen Gooxi Hengyu Technology Co., Ltd
2.4 Introduction to the Installation Steps of Gooxi3116 Chassis Power Supply
(1) Place the power supply case to the chassis according to the hole site, as shown in
the figure below.
(2) Fix the power supply bracket, and screw on the screws at the position marked in
the figure below.

Shenzhen Gooxi Hengyu Technology Co., Ltd
(3)Insert the hot-swappable power modules PSU1 and PSU2, respectively
(4)The final installation effect of power supply

Shenzhen Gooxi Hengyu Technology Co., Ltd
2.5 Introduction to the Installation Steps of Motherboard on Gooxi 3116 Chassis
(1) Open the chassis, and place insulation pad according to the correct orientation.
Based on the hole of motherboard screw, motherboard active stud (8mm height) is
installed at the corresponding position on the insulation pad. As shown in the figure
below: Install Gooxi G1DE-4B dual circuit motherboard corresponding to the base
hole site.

Shenzhen Gooxi Hengyu Technology Co., Ltd
(2) After the motherboard active stud (8mm height) is installed, place the motherboard
into the chassis and fasten motherboard screw at the hole site. As shown in the figure
below:
2.6 Introduction to the Installation Steps of Built-in 2.5-inch Hard Drive on
Gooxi3116 Chassis
⑴Dismantle the front cover.
(2)Install the 2.5-inch hard disk on the bracket.

Shenzhen Gooxi Hengyu Technology Co., Ltd
(3) As shown below: Install two 2.5-inch modules on the inside of the chassis

Shenzhen Gooxi Hengyu Technology Co., Ltd
(4) Completed installation effect
(5) Completed installation effect of two built-in hard disks
2.7 Introduction to the Installation Steps of Rear Hot-swappable 2.5-inch Hard
Drive on Gooxi3116 Chassis
(1) Replace the rear window of CRPS power supply case, the rear window suite
supports the installation of 2.5 modules. As shown below: Install the 2.5-inch module.
Popular Network Hardware manuals by other brands

PairGain
PairGain HiGain SOLITAIRE H2TU-C-319 List 1 Technical practice

Panasonic
Panasonic WJ-NX200K installation guide

HMS Networks
HMS Networks Airconwithme Device Configuration

PairGain
PairGain PG-Flex FSU-796 Quick reference guide

Tandberg Data
Tandberg Data Autoloader Tandberg LTO2 Installation and user manual

Wisstar
Wisstar WP-N6632-M4 user manual

ExtraHop
ExtraHop Discover EDA 6200 Replace

CommScope
CommScope RUCKUS SmartZone 300 Quick setup guide

Tiger Technology
Tiger Technology Project Serve Assembly guide

Broadcast Tools
Broadcast Tools COP-2/RJ Installation and operation manual

Elan
Elan EL-NVR series owner's manual

Emerson
Emerson ACC/ARTM-7221/SCSI installation guide