152-319-100-02, Revision 02 Front Panel
H2TU-C-319 List 1 and List 1C April 21, 2000 7
LOOPBACK MESSAGES continued
SMJK Remote SmartJack Loopback DSX-1 signal is looped back to the network at the H2TU-R
SmartJack module.
DIAGNOSTIC MESSAGES
A = xx Maximum Loop Attenuation The Attenuation (A) message appears followed by xx, where xx is the
loop attenuation of the longest (maximum loss) span, measured in dB.
ACQ Acquisition The multiplexers of the H2TU-C and H2TU-R (or the H2TU-C and
first regenerator) are trying to establish synchronization over the
HDSL2 loop of Span 1.
AnLAcquisition nLoop The multiplexers of the two devices on Span nare trying to establish
synchronization with each other, where nis the span number.
ARM HiGain System Armed Armed to respond to Intelligent Repeater Loop (ILR) codes.
BAD RT? No Response from H2TU-R The H2TU-C receives no response from the H2TU-R, and all HDSL2
loop conditions are normal. Therefore, the integrity of the H2TU-R
or the HDSL2 loop is questionable.
FERR Framing Bit Error Occurred Framing bit error occurred at H2TU-C DSX-1 input.
FLDL Flash Download Flash download of firmware updates. Contact Customer Service for
update procedures (see “Appendix D - Product Support” on page 56).
HES HDSL2 CRC Error H2TU-C HDSL2 Loop Cyclical Redundancy Check (CRC) error.
LBPV Local Bipolar Violation A bipolar violation has been received at the DSX-1 input to the
H2TU-C-319.
M=xx HDSL2 Loop Margin Indicates the power of the received HDSL2 signal relative to noise
(S/N with respect to 21.5 dB). Any value of 6 dB or greater is
adequate for reliable system operation.
MNGD Managed The H2TU-C-319 is under control of the HMU-319 Network
management unit. In this state, the front-panel craft port and push
buttons are disabled.
PWR FEED OFF Power Feed Off HDSL2 span power has been turned off by setting the PWRF option
to off, or HDSL2 span power has been turned off by use of the A1LB,
A2LB, and A5LB Intelligent Office Repeater (IOR) Power Down code.
PWR FEED ON Power Feed On Indicates that the HDSL2 loop is not grounded or shorted.
SIG Signaling The transceivers of the H2TU-C and H2TU-R (or the H2TU-C and
first regenerator) are trying to establish contact with each other over
the HDSL2 loop of Span 1.
SnLSignal nLoop The transceivers of the two devices on Span nare trying to establish
contact with each other, where nis the span number.
SYSTEM INFORMATION MESSAGES (a)
CODE xxxx Line Code: AUTO, AMI or B8ZS The line code that the H2TU-C is receiving at its DSX-1 interface, if
the DS1 option is set to AUTO. Otherwise, it mimics either of the
other two DS1 line code settings: Alternate Mark Inversion (AMI) or
Bipolar with 8-Zero Substitution (B8ZS).
FRM xxxx Frame: SF, ESF, UNFR Defines the type of frame pattern being received from the DSX-1:
SuperFrame (SF), Extended SuperFrame (ESF), Unframed (UNFR).
LATT xx Loop Attenuation The current loop attenuation threshold setting measured in dB.
LIST xx H2TU-C-319 List Number The list number of the H2TU-C-319.
MARG xx Margin The current margin threshold setting measured in dB.
VER x.xx H2TU-C-319 Software Version Number The software version number (x.xx).
(a) System information messages are displayed in scroll mode. To scroll through the messages, press the MODE button for 3 or
more seconds.
Table 2. Front-panel Display Messages (List 1 Only) (Cont.)
Message Full Name Description