3. Brief description
The signal isolator SINEAX TI 816 serves to electrically insulate an analogue DC
signal in the range 0...20 mA which depending on version is then converted to a
current or voltage signal (0...20 mA or 0...10 V). It does not require a separate power
supply.
Fig. 1
1With current signal
2With voltage signal
Safety precautions to be
strictly observed are marked
with following symbols in the
operating instructions:
The instrument fulfils all the important requirements and regulations concerning
electromagnetic compatibility EMC and Safety (IEC 1010 resp. EN 61 010). It was
developed and is manufactured and tested in strict accordance with the quality
assurance standard ISO 9001.
4. Versions
There are two versions of the DC signal isolator SINEAX TI 816 available.
Description Output Order code Order No.
signal A
Passive DC signal isolator
input signal E: 0…20 mA, 0…20 mA 816-5110 990 722
with 1 isolation and
transmission channel, in
carrying rail housing N12 0…10 V 816-5111 994 089
5. Technical data
Input signal E
DC current: 0…20 mA
Max. permissible current: 50 mA
Voltage limiter: 18 V ±5% (with zener diode)
Voltage drop: < 2 V (for 500 Ωburden)
Overshoot: < 20 µA (typical 5 µA)
Output signal A
DC current or
DC voltage: 0…20 mA or 0…10 V
Limit: Approx. 30 mA1
Approx. 15 V2
Max. burden: 600 Ω1
Internal resistance: 500 Ω2
Residual ripple: < 20 mV ss
Time constant: Approx. 5 ms
Accuracy data
Error limits: < ±0,1%1
(reference value 20 mA,
linearity error included)
< ±0,2%2
(reference value 10 V,
linearity error included)
Ambient conditions
Operating temperature:: –20 to + 65 °C
Storage temperature: –40 to + 85 °C
Annual mean
relative humidity: ≤75% Standard climatic rating
Seismic test: 5 g, < 200 Hz, 2 h in each of 3 directions
Shock test: 50 g, 10 shocks in each of 3 directions
Contents
1. Read first and then … .................................................................................... 1
2. Scope of supply ............................................................................................. 1
3. Brief description ............................................................................................ 1
4. Versions ......................................................................................................... 1
5. Technical data ............................................................................................... 1
6. Mounting ........................................................................................................ 2
7. Electrical connections ................................................................................... 2
8. Commissioning and maintenance ................................................................. 2
9. Releasing the signal isolator .......................................................................... 2
10. Dimensional drawings ................................................................................... 2
1. Read first and then …
The proper and safe operation of the device assumes that
the operating instructions is read carefully and the safety
warnings given in the various Sections
6. Mounting
7. Electrical connections
are observed.
The device should only be handled by appropriately trained
personnel who are familiar with it and authorised to work
in electrical installations.
2. Scope of supply
Signal isolator (Fig. 1)
1 ea. operating instructions (Fig. 2) in English, French, German
Fig. 2