Graco Pulse 25T460 User manual

3A8507C
EN
Instructions
Pulse® Level
WiFi Tank Level Monitor
Measures the distance between the device and the surface of the fluid to determine the
volume of fluid within a tank. For use only with Pulse Level. Intended fluids: oil, diesel,
waste oil, automatic transmission fluid (ATF), kerosene, anti-freeze, windshield washer
solution, waste water, and DEF. For professional use only. Not suitable for tank overfill
protection.
Not approved for use in explosive atmospheres or hazardous (classified) locations.
Part No. 25T460
Important Safety Instructions
Read all warnings and instructions in this
manual and in all related Pulse manuals
before using the equipment. Save all
instructions.
WARNING
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
• Do not alter or modify equipment. Alterations or
modifications may void agency approvals and
create safety hazards.
• Make sure all equipment is rated and approved for
the environment in which you are using it.
• Use equipment only for its intended purpose. Call
your distributor for information.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.
PERSONAL PROTECTIVE EQUIPMENT
Wear appropriate protective equipment when in the
work area to help prevent serious injury, including
eye injury, hearing loss, and inhalation of toxic fumes.
This Tank Level Monitor (TLM) contains FCC ID 56T784.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
• This device may not case harmful interference.
• This device must accept any interference received,
including interference that may cause undesired
operation.

Installation
2 3A8507C
Installation
Set Up
Connecting to a Network
Summary
Please refer to the instructions in this section, unless
indicated otherwise.
1. Press and hold the button on the top of the Pulse
sensor until the LED light turns red.
2. Using a mobile device (e.g. laptop, smart phone,
tablet), search for a WiFi network beginning with
GRACO and connect.
3. Open a web browser and enter “192.168.4.1” into
the address bar.
4. After the WiFi settings page is loaded, select the
intended WiFi network from the drop down bar.
5. Enter the selected WiFi network password.
6. Click the Connect to WIFI button.
7. The LED on the Pulse sensor turns green (FIG. 3).
8. Wait approximately 20 seconds.
9. The sensor flashes red or green several times.
• Green flashes indicate that a connection to the
network has been established.
• Red flashes indicate that a connection to the
network has not been established. The number of
red flashes identifies the problem:
NOTICE
• Do not over tighten TLM into tank bung. Over
tightening can cause permanent damage and
result in inaccurate readings.
• Do not use the TLM with pressurized tanks. Using
the TLM in a pressurized tank will damage the
TLM.
• Do not use thread sealant or adhesive. Many of
these products are chemically incompatible with
the ABS plastic threads.
FIG. 1
FIG. 2
FIG. 3
LED light

Installation
3A8507C 3
Error Flash Patterns (LED)
Register TLM to Tank in Pulse
Level Software
Assign a TLM serial number to a tank in Pulse Level.
Navigate to URL: level.gracopulse.com
After creating user, organization, branch and site,
navigate to Devices (located in the upper right corner of
the screen). Associate the device to your organization
by entering the serial number and activation code.
When you create a tank for the site, the device will be
assignable.
Typical Installation
Mount Options
Identify a threaded opening on the top of the tank for
the sensor. The location should be vertical with a clear
path to the contents of the tank. There should be no
obstructions that could interfere with the signal.
1. If the hole is not threaded, place the foam gasket
(included with kit) over the opening.
2. Place the mounting adapter (included with kit) on
top of the foam gasket.
3. Use the two (2) stainless steel self-tapping,
counter-sunk screws (included with kit) to attach
the adapter to the tank. Do not over tighten.
4. Attach the sensor to the adapter. To form a secure
seal, make sure that the sensor is vertical on the
tank, that it is secured correctly to the base, and
that the threads have not crossed.
NOTE: If the tank does not contain a suitably positioned
opening at the top of the tank, reference Drilling, page
4.
No. of
Flashes Function Resolution
1 Unable to find WiFi
network
Verify that Connect to
WiFi was selected on
the browser
2 Unable to connect to
WiFi network
Improve WiFi signal
strength or enable
MAC filtering on the
router
3 WiFi password is
incorrect
Verify information
entered is correct
Verify that the WiFi
network’s security
supports WEP, WPA, or
WPA2 security
5 Pulse Level is
unavailable
Confirm that port 80 is
not blocked for your
device IP address
6 Invalid response
from the Pulse Level
Retry
7 Firmware download
failed
Check that the network
is up and stable before
trying again
8 Low battery Change batteries
9 Critical failure Replace the Tank Level
Monitor
FIG. 4

Installation
4 3A8507C
Installation Examples
Drilling
If the tank does not contain a suitable positioned
opening at the top of the tank, it will be necessary to
manually drill into the top of the tank.
1. Select a flat area on the top of the tank located
towards the center (FIG. 5).
2. Drill a 1.5 in. bsp hole at the selected area using a
45.5 mm tapping drill.
3. Continue with Mount Options, steps 1 through 4.
Operation
View Data
The TLM can be configured with the Pulse Level
(level.gracopulse.com) to take a reading at predefined
times.
After configuring the TLM using the TLM Pulse Level,
press the button until the green LED is lit, to create a
connection between the TLM and the Pulse Level to
load the configuration.
NOTE: Frequent measurements result in shorter battery
life.
Manual Measurement
To force a measurement:
1. Press and hold the button until the green light
illuminates.Release the button.
FIG. 5
FIG. 6

Installation
3A8507C 5
Recycling and Disposal
End of Product Life
At the end of the product’s useful life, dismantle and
recycle it in a responsible manner.
• Remove batteries, circuit boards, LCDs (liquid
crystal displays), and other electronic components.
Recycle according to applicable regulations.
• Do not dispose of batteries or electronic
components with household or commercial waste.
• Deliver remaining product to a recycling facility.
Troubleshooting
Problem Cause Solution
Monitor is not reporting scheduled
readings.
Out of WiFi range.
WiFi obstruction.
Ensure that the TLM is not encased
in metal, since this would obstruct
the signal.
Take a manual measurement and
review LEDs during the
measurement.
Weak or dead batteries. Replace batteries. See Replace
Batteries, page 6.
Tank Level Monitor was not
associated with profile after
scheduled times were entered into
software.
Assign TLM serial number to a
tank. Press TLM button to take a
manual reading.
Reading is scheduled when pump
is operating.
Ensure readings are scheduled
during times that the pump is not
operating.
LED will not turn on. Button released too soon. Hold button down for a longer
period of time.
Weak or dead batteries. Replace batteries. See Replace
Batteries, page 6.

Service
6 3A8507C
Service
After the TLM has been installed, the only additional
maintenance or service necessary is changing the
batteries.
Replace Batteries
1. Remove the TLM adapter from the tank.
2. Remove the four screws that keep the case
together (FIG. 7).
3. Carefully pull the TLM case halves apart to access
the battery (FIG. 8).
NOTE: The TLM case halves are tightly connected. Use
caution when opening the device to prevent
unnecessary damage.
4. Replace the 3.6V C-size battery. See Technical
Specifications, page 8, for battery information.
Install the battery as shown in FIG. 9, with the
positive end on the right. This is the clip that has
shrink tubing on it.
5. To maintain the IP rating, make sure that the gasket
is properly installed (FIG. 9).
6. Reconnect the two halves and replace the four
screws.
WARNING
Fire and Explosion Hazard
Sparking can occur when changing batteries. Only
replace the batteries in a non-hazardous location
away from flammable fluids and fumes.
NOTICE
After battery placement, press the button to synchronize
the TLM internal clock to maintain scheduled TLM
readings.
FIG. 7
Screws
FIG. 8
FIG. 9
Place Gasket
Here

Dimension - Tank Specifications
3A8507C 7
Dimension - Tank Specifications
Vertical Tank:
• Maximum Volume - 999,999 gallons or liters.
• Tank walls must be uniformly vertical from empty
level to full.
Cylindrical Tank:
• Maximum volume = 999,999 gallons or liters.
• Tank end walls must be flat; they cannot be any
other shape, including belled.
Obround Tank:
• Maximum volume = 999,999 gallons or liters.
• Tank end walls must be flat; they cannot be any
other shape, including belled.
Non-Standard Tanks:
• Maximum volume = 999,999 gallons or liters.
• Define strapping table in Pulse Level Software.
• Up to 100 strapping table points to correlate tank
fluid height to volume.
FIG. 10
FIG. 11
FIG. 12
Width

Technical Specifications
8 3A8507C
Technical Specifications
California Proposition 65
Tank Level Monitor (TLM)
US Metric
Compatible Fluids
oil, kerosene, diesel, lubricants, additives, DEF/AdBlue®, coolants,
water, waste oil, waste water, automatic transmission fluid (AFT),
anti-freeze, and windshield washer solution
Ultrasonic Tank Depth Measurement range 5.0 in. to 9 ft. 7 in. 12 cm (minimum) to 300 cm
Fluid Level Measurement Accuracy +/- 1.0 in. +/- 2.0 cm
Mounting 1.25 in., 1.5 in, and 2.0 in. threaded npt connector
Clearance: Height above tank for TLM 7.5 in. 19.1 cm
Weight 0.5 lb. 226.8 g
RF Frequency Band 2.412 GHz - 2.462 GHz
Maximum RF Transmit Power 18 dBm
Operating Temperature Range 0°F to 122°F -17.8°C to 50°C
Storage Temperature Range 0°F to 122°F -17.8°C to 50°C
Batteries Li-SOCl2 Size R14, 3.6V C-cell
Battery Life 7.5 years* from activation
Enclosure (Ingress Protection) IP67
Tanks
Maximum Volume 999,999 gallons 999,999 liters
Maximum Height 9 ft. 7 in. 300 cm
Altitude <6,000 ft. < 2 km
* The battery life is based upon four (4) measurements per day and one (1) WiFi connection per day from a location
where the WiFi coverage does not require retries, and a normal distribution over the operating temperature range
centered at +25°C (77°F).
All trademarks or registered trademarks are the property of their respective owners.
CALIFORNIA RESIDENTS
WARNING: Cancer and reproductive harm – www.P65warnings.ca.gov.

Graco Extended Warranty
3A8507C 9
Graco Extended Warranty
Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of
sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a
period of twenty four months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This
warranty applies only when the equipment is installed, operated and maintained in accordance with Graco's written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification
of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be
returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or
workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO
WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco's sole obligation and buyer's sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental
or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale Graco makes
no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories,
equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric
motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance
in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder,
or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered
into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu
que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés
à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
Graco Information
For the latest information about Graco products, visit www.graco.com.
For patent information, see www.graco.com/patents.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590

All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 3A8507
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2021, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com
Revision C, August 2021
Table of contents