Graco Husky A Series User manual

Instructions – Parts List
GRACO INC.ąP.O. BOX 1441ąMINNEAPOLIS, MNą55440-1441
Copyright 1996, Graco Inc. is registered to I.S. EN ISO 9001
Husky tLeak Detectors
For use with air operated double diaphragm pumps. Shuts off pump and prevents fluid from
escaping.
60 psi (0.41 MPa, 4.1 bar) Maximum Incoming Air Pressure
Model 239080, Series A
polypropylene housing, PVC wetted parts
Model 239081, Series A
acetal housing, stainless steel wetted parts
308702 rev.D
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Model 239081 shown
06843
Contents
Symbols 2. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warnings 2. . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation 4. . . . . . . . . . . . . . . . . . . . . . . . . .
Operation 8. . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance 9. . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting 9. . . . . . . . . . . . . . . . . . . . .
Service 10. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts Lists 12. . . . . . . . . . . . . . . . . . . . . . . . .
Parts Drawing 13. . . . . . . . . . . . . . . . . . . . . .
Technical Data 14. . . . . . . . . . . . . . . . . . . . .
Dimensions 14. . . . . . . . . . . . . . . . . . . . . . . .
Graco Standard Warranty 16. . . . . . . . . . . .
Graco Information 16. . . . . . . . . . . . . . . . . .
Parts

2 308702
Symbols
Warning Symbol
WARNING
This symbol alerts you to the possibility of serious
injury or death if you do not follow the instructions.
Caution Symbol
CAUTION
This symbol alerts you to the possibility of damage to
or destruction of equipment if you do not follow the
instructions.
Warnings
WARNING
INSTRUCTIONS
EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
DThis equipment is for professional use only.
DRead all instruction manuals, tags, and labels before operating the equipment.
DUse the equipment only for its intended purpose. If you are not sure, call your Graco distributor.
DDo not alter or modify this equipment.
DCheck equipment daily. Repair or replace worn or damaged parts immediately.
DDo not exceed the maximum working pressure of the lowest rated component in your system.
This equipment has a 60 psi (0.41 MPa, 4.1 bar) maximum incoming air pressure.
DUse fluids and solvents that are compatible with the equipment wetted parts. Refer to the
Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s
warnings.
DDo not lift pressurized equipment.
DComply with all applicable local, state, and national fire, electrical, and safety regulations.

308702 3
WARNING
TOXIC FLUID HAZARD
Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin,
inhaled, or swallowed.
DKnow the specific hazards of the fluid you are using.
DStore hazardous fluid in an approved container. Dispose of hazardous fluid according to all local,
state, and national guidelines.
DAlways wear protective eyewear, gloves, clothing, and respirator as recommended by the fluid and
solvent manufacturer.
DPipe and dispose of the exhaust air safely, away from people, animals, and food handling areas.
DNever use an acetal pump or leak detector with acids. Take precautions to avoid acid or acid
fumes from contacting the pump housing exterior. Stainless steel parts will be damaged by
exposure to acid spills and fumes.
FIRE AND EXPLOSION HAZARD
Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and
result in a fire or explosion and serious injury.
DGround the equipment. Refer to Grounding on pages 5 and 6.
DNever use a polypropylene pump or leak detector with non-conductive flammable fluids as
specified by your local fire protection code. Refer to Grounding on pages 5 and 6 for additional
information. Consult your fluid supplier to determine the conductivity or resistivity of your fluid.
DIf there is any static sparking or you feel an electric shock while using this equipment, stop
pumping immediately. Do not use the equipment until you identify and correct the problem.
DProvide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid
being pumped.
DPipe and dispose of the exhaust air safely, away from all sources of ignition.
DKeep the work area free of debris, including solvent, rags, and gasoline.
DElectrically disconnect all equipment in the work area.
DExtinguish all open flames or pilot lights in the work area.
DDo not smoke in the work area.
DDo not turn on or off any light switch in the work area while operating or if fumes are present.
DDo not operate a gasoline engine in the work area.

4 308702
Installation
Reference numbers and letters in parentheses refer to
the callouts in the figures and in the Parts Lists on
page 12 and the Parts Drawing on page 13.
CAUTION
A second shut-off valve is recommended for any
pressure- or gravity-fed applications. It is shown in
Fig. 1. See Inlet Shut-Off Valve Kit on page 11.
1. Mount the leak detector securely and in an upright
position as shown in Fig. 1.
2. Install the shut-off valve (1) directly to the air inlet
port of the air-operated diaphragm pump. It
makes no difference whether the shut-off valve is
installed before or after any air regulator installed
in the system.
NOTE: Install the shut-off valve (1) so that the IN
port points toward the source air line and the OUT
port points toward the pump.
3. Install a hose, with a maximum pressure rating at
least as high as the system air pressure, from the
pump exhaust port to the leak detector inlet port.
See the list in Fig. 1 for hose part numbers.
NOTE: You may use rigid piping; however, you
should use at least 6 in. (150 mm) of flexible hose
to connect the rigid pipe to the leak detector port.
4. Connect a 1/4-in. air line to the quick-connect male
air line fitting (10) on the regulator (8).
5. Adjust the regulator (8) pressure to 50 to 60 psi
(0.34 to 0.41 MPa, 3.4 to 4.1 bar).
NOTE: Because the shut-off valve (1) is a
normally closed valve, the pump will not operate
unless an air line is connected to the leak detector
air line fitting (10).
6. Ground the leak detector and, if appropriate, the
fluid containers. See Grounding on pages 5
and 6.
7. See Operating Instructions on page 8.
The installation shown in Fig. 1 is only a guide for connecting the leak detector to your system. Contact your Graco
distributor for assistance in planning a system to suit your needs.
06845A
Fig. 1
1leak
detector
inlet port
pump
exhaust
port
8
10
air line
06846
see detail
DETAIL
connected
to shut-off valve
fluid hose
Order a fluid hose from the list below:
221170 coupled, 3/4 npt, 3 ft long
221171 coupled, 3/4 npt, 6 ft long
H53806 coupled, 3/8–18 npsm, 6 ft long
Second shut-off valve is part of Inlet Valve
Shut-Off kit 239114, which may be purchased
separately.
1
1

308702 5
Installation
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
When pumping flammable fluids, this
leak detector must be grounded. Before
pumping, ground the system as ex-
plained below. Also read the section
FIRE OR EXPLOSION HAZARD on
page 3.
The polypropylene leak detectors are not
conductive. Attaching the ground wire to the lug
(15) grounds only the clamp (see Fig. 2). When
pumping conductive flammable fluids, always
ground the entire fluid system by making sure the
fluid has an electrical path to a true-earth ground.
To reduce the risk of static sparking, ground the leak
detector and all other equipment in the pumping area.
Check your local electrical code for detailed grounding
instructions for your area and type of equipment.
Ground all of this equipment:
DLeak detector: Attach a ground wire to the
grounding lug (15) as shown in Fig. 2. Connect the
clamp end of the ground wire to a true earth
ground. To order a ground wire and clamp, order
Part No. 222011.
NOTE: To connect the ground wire to the leak
detector, first remove the copper connector from
the non-clamp end of the ground wire and discard
it, then push the bare wire through the grounding
lug on the leak detector.
Fig. 2
ground
wire
15
DFluid supply container: Follow your local code.
NOTE: When pumping conductive flammable
fluids, always ground the entire fluid system. See
the WARNING at left. Fig. 3 shows a
recommended method of grounding fluid containers
during filling. This is only a guide; contact your
Graco distributor for assistance in grounding your
system.
DAir compressor: Follow the manufacturer’s
recommendations.
DSolvent pails used when flushing: Follow your local
code. Use only grounded metal pails, which are
conductive. Do not place the pail on a
non-conductive surface, such as paper or
cardboard, which interrupts the grounding
continuity.

6 308702
Installation
pump air supply
WS
A Husky pump
B Husky leak detector
H Fluid drain valve (required)
S Dispense valve
T Fluid drain line
Y Air motor ground wire (required)
W Leak detector ground wire (required)
See page 5 for installation instructions.
Z Container ground wire (required)
Fig. 3
1
2
Grounding a Leak Detector
Hose must be conductive.
Dispense valve nozzle must be in contact with
the container.
A
H
T
Y
1
2
06849
B
Z

308702 7
Notes

8 308702
Operation
Pressure Relief Procedure
WARNING
PRESSURIZED EQUIPMENT HAZARD
The equipment stays pressurized until pressure is
manually relieved. To reduce the risk of serious
injury from pressurized fluid, accidental spray, or
splashing fluid, follow this procedure whenever you:
DAre instructed to relieve pressure
DStop pumping
DCheck, clean, or service any system equipment
DInstall or clean fluid nozzles
1. Shut off the air to the pump.
2. Open the dispensing valve, if used.
3. Open the fluid drain valve to relieve all fluid
pressure, and have a container ready to catch the
drainage.
WARNING
TOXIC FLUID HAZARD
Hazardous fluid or toxic fumes can
cause serious injury or death if splashed
in the eyes or on the skin, inhaled, or
swallowed.
DRead TOXIC FLUID HAZARD on page 3.
DUse fluids and solvents that are compatible with
the equipment wetted parts. Refer to the
Technical Data section of all equipment
manuals. Read the fluid and solvent
manufacturer’s warnings.
WARNING
FIRE AND EXPLOSION HAZARD
Never pump flammable fluids with
polypropylene units. Such use could
cause a fire or an explosion.
Operating Instructions
See Parts Drawing on page 13.
DWhen compressed air is applied to the pump and
the leak detector, the pump operates as it would
under normal operating conditions. Exhaust air
from the pump flows into the leak detector and out
of the leak detector silencer (R). See the Parts
Drawing on page 13.
DIf the pump diaphragm leaks, liquid may enter the
pump’s air exhaust and be carried to the leak
detector. When liquid accumulates in the leak
detector, the float (4) rises, and air flow is diverted
to a different hose in the the three-way valve (M).
As a result, air pressure is removed from the
shut-off valve (1), which closes it and stops the
pump.
When the leak detector triggers a pump shutdown, you
should suspect that a pump diaphragm has failed, and
you should respond as follows:
1. Shut off all air to the pump and the leak detector.
2. Shut off the fluid supply to the pump.
3. Drain the liquid from the leak detector through the
drain valve (B) into a suitable container, depending
on the liquid being pumped.
4. If the liquid that comes out of the drain valve (B) is
only water condensation, no corrective action is
necessary. Close the drain valve, open the fluid
supply line, and resume pumping.
If the liquid being pumped comes out of the drain
valve (B), repair the pump immediately to minimize
internal damage to the pump. Additionally, the
leak detector must be serviced. See Cleanup
After a Leak.
Cleanup After a Leak
If a spill occurs with tacky or viscous fluid, the fluid
could solidify and interfere with the action of the
moving parts. It is recommended that you check the
following parts for cleaning or replacement any time
the leak detector is activated (See Parts Drawing on
page 13):
DConcentrator (3)
DFloat (4)
DPush rod (5)
DCompression nut (6)
DConverter o-ring (12)
DDrain valve (B)

308702 9
Maintenance
For instructions on cleaning the inside of the leak
detector and performing an actuator valve test, see
Routine Cleaning and Test on page 10. For a
function test that does not involve any disassembly,
perform the following steps (See Parts Drawing on
page 13):
1. Relieve the pressure, and turn off the air supply
to the pump and the leak detector.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
2. Remove the test port plug (G) on the leak detector,
and half fill the unit with water.
3. Turn on the air supply to the pump and the leak
detector.
The pump should not operate. If the pump
operates, the the leak detector actuator valve (M)
may be defective and may need to be replaced.
Contact your Graco distributor. Another possibility
is that the compression nut (6) may be too tight
and is not allowing the float to slide up the rod
guide (A).
If the pump does not operate, go to step 4.
4. Turn off the air supply to the pump and the leak
detector, drain the leak detector through the drain
valve (B), and replace the test port plug (G).
5. Turn on the air supply to the pump and the leak
detector.
The pump should function normally.
Troubleshooting
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
Relieve the pressure before checking or servicing the
equipment.
Check all possible problems and causes before
disassembling the leak detector.
PROBLEM CAUSE SOLUTION
Leak detector does not cause pump
to shut off during a leak and float is
raised
Actuator valve (M) is faulty and
needs to be replaced.
Contact your Graco distributor.
raised. Shut-off valve (1) should be
installed at pump inlet with IN port
toward the source air line and the
OUT port toward the pump.
Make sure shut-off valve (1) is
installed correctly.
Leak detector does not cause pump
to shut off during a leak and float
Compression nut (6) is too tight. Loosen nut slightly.
to shut off during a leak and float
does not rise. Push rod (5) is dirty. Clean push rod.
does
not
rise
.
Drain valve (B) has been left open. Close drain valve.
Fluid from pump leak has accumu-
lated in hose that runs from pump
exhaust to leak detector.
Adjust installation so that fluid from
pump will drain down into leak
detector.
Leak detector shuts down pump,
but there is no diaphragm failure in
pump.
Water condensation from pump
exhaust has collected in leak
detector and raised the float, which
simulates a leak and shuts down
the pump.
Shut off air to pump and leak
detector, drain water out of leak
detector by opening the drain valve
(B), turn air back on, and resume
pumping.

10 308702
Service
Routine Cleaning and Test
See the Parts List on page 13.
1. Relieve the pressure, and disconnect the
compressed air supply to the pump and leak
detector.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
2. Remove the clamp (7), and remove the leak
detector lid (L).
3. Flush the inside of the leak detector with water or
a cleaner compatible with the liquid that has been
pumped.
4. To test the leak detector, connect an air line to the
leak detector air line fitting (10), and disconnect
the vinyl tube (2) at the pump shut-off valve (1).
5. Turn on the air.
Air should be flowing through the tube (2).
6. Push the float (4) up to simulate a detected leak.
Air should stop flowing through the shut-off valve
tube (2) and be redirected to flow out the alternate
air outlet. If air does not stop flowing, the leak
detector actuator valve (M) is defective and needs
to be replaced. Contact your Graco distributor.
If air flow through the shut-off valve tube (2) stops
when you raise the float, the leak detector is
operating correctly. Reassemble the leak detector,
and set the regulator at 50 to 60 psi
(0.34 to 0.41 MPa, 3.4 to 4.1 bar).

308702 11
Service
Inlet Shut-Off Valve Kit
Inlet Shut-Off Valve Kit 239114 is available. Parts
included in the kit are marked with a dagger, for
example (2{), in the Parts Lists on page 12 and in
Fig. 4. In addition to the part marked with a dagger,
the kit includes the following: 1/4-in tube x 1/8 npt tube
connector, 3/4-in close SST nipple, brass tube tee, and
sleeveless bushing.
You should use this second shut-off valve kit for any
pressure- or gravity-fed applications. If a diaphragm
failure occurs in a pressure- or gravity-fed application,
even after the leak detector shuts off the air supply to
the pump it is possible for fluid to be pushed through
the failed diaphragm and through the pump exhaust,
and it could overflow the leak detector. The second
shut-off valve in Inlet Shut-Off Valve Kit 239114, when
activated, stops any fluid from entering the leak
detector when the pump is shut down.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
Relieve the pressure. Install the new shut-off valve
(1{) at the leak detector inlet. Run the original air line
(2) from the tee (Z) to the original shut-off valve (1).
Run the new air line (2{) from the tee to the new
shut-off valve (1{) as shown in Fig. 4. Connect the
pump exhaust line to the new shut-off valve.
If a spill occurs, see Cleanup After a Leak on
page 8.
Fig. 4
1
1{
Z
leak detector inlet port
from
pump
exhaust
to pump
air inlet
pump air
supply line
2
connected
to shut-off
valve (1)
06844
06846

12 308702
Parts Lists
Model 239080, Series A
polypropylene housing, PVC wetted parts
A Rod guide, TFE-coated SST; 1/8” x 3” nipple
B Drain valve, PVC
C Elbow, PVC; 3/4”
D Nipple, PVC; 1/2”
E Stand, painted mild steel
F Nipple, PVC; 3/4”
G Hex plug, brass
H Reducer bushing, PVC
J Regulator stand, SST; 1/4” x 4” nipple
K Housing, polypropylene
L Lid, thermoplastic
M Actuator valve, aluminum
N Machine screw, SST; 7/8” #8
P Sleeveless bushing, zinc-plated steel;
1/8” x 1/4”
R Silencer reclassifier, cast aluminum, brass,
and polycarbonate; 1/2”
S Barbed tube connector, brass; 1/4” x 10–32
T Push-in tube connector, brass; 1/4 x 1/8 npt
U O-Ring cord, buna–N
Z Tee, brass
Replacement Parts
Ref
No. Part No. Description Qty
1{113870 VALVE, shut-off, cast aluminum 1
2{113871 TUBE, vinyl; 1/4” O.D. x 8’ long 2
3 113873 CONCENTRATOR, PVC 1
4 113900 FLOAT, polypropylene; 5” 1
5 113898 ROD, push, TFE-coated SST 1
6 113897 NUT, cmprssn, TFE-coated brass 1
7 113872 CLAMP, band, SST 1
8 110318 REGULATOR; 1/4” & 1/8” ports 1
9 108190 PRESSURE GAUGE, air 1
10 169970 FITTING, air line, quick-connect 1
11 108000 NUT, lock, SST; 5/1624 1
12 156454 O-RING, buna–N 1
13 186620 STICKER, grounding symbol 1
15 104029 LUG, grounding 1
16 104582 WASHER TAB, grounding 1
18 290305 LABEL, product (not shown) 1
19 290306 TAG, identification (not shown) 1
20 290321 LABEL, warning (not shown) 1
{Part of Inlet Shut-Off Valve Kit 239114, which may
be purchased separately. See page 11.
Model 239081, Series A
acetal housing, stainless steel wetted parts
A Rod guide, TFE-coated SST; 1/8” x 3” nipple
B Drain valve, SST
C Elbow, SST; 3/4”
D Nipple, SST; 1/2”
E Stand, painted mild steel
F Nipple, SST; 3/4”
G Hex plug, SST
H Reducer bushing, SST
J Regulator stand, SST; 1/4” x 4” nipple
K Housing, acetal (conductive)
L Lid, thermoplastic
M Actuator valve, aluminum
N Machine screw, SST; 7/8” #8
P Sleeveless bushing, zinc-plated steel;
1/8” x 1/4”
R Silencer reclassifier, cast aluminum, brass,
and polycarbonate; 1/2”
S Barbed tube connector, brass; 1/4” x 10–32
T Push-in tube connector, brass; 1/4 x 1/8 npt
U O-Ring cord, buna–N
V Drain plug, SST; 2”
W Nipple, SST; 1/4”
Y Drain elbow, SST
Z Tee, brass
Replacement Parts
Ref
No. Part No. Description Qty
1{113870 VALVE, shut-off, cast aluminum 1
2{113871 TUBE, vinyl; 1/4” O.D. x 8’ long 2
3 113921 CONCENTRATOR, SST 1
4 113899 FLOAT, SST; 5” 1
5 113988 ROD, push, TFE-coated SST 1
6 113897 NUT, cmprssn, TFE-coated brass 1
7 113872 CLAMP, band, SST 1
8 110318 REGULATOR; 1/4” & 1/8” ports 1
9 108190 PRESSURE GAUGE, air 1
10 169970 FITTING, air line, quick-connect 1
11 108000 NUT, lock, SST; 5/16–24 1
12 156454 O-RING, buna–N 1
13 186620 STICKER, grounding symbol 1
15 104029 LUG, grounding 1
16 104582 WASHER TAB, grounding 1
18 290305 LABEL, product (not shown) 1
19 290306 TAG, identification (not shown) 1
20 290321 LABEL, warning (not shown) 1
{Part of Inlet Shut-Off Valve Kit 239114, which may
be purchased separately. See page 11.

308702 13
Parts Drawing
06842
B
Model 239080
R
{Part of Inlet Shut-Off Valve Kit 239114. See page 11.
1Vinyl tube (2) runs from regulator (8) to actuator
valve (M) and runs separately from shut-off
valve (1) to actuator valve (M). See Fig. 1 on
page 4.
Model 239080, Series A
polypropylene housing, PVC wetted parts
Model 239081, Series A
acetal housing, stainless steel wetted parts
Model 239081, Series A shown
H
D
C
C
G
F
L
7
3
4
K
E
A
5
6
12
U
{2
P
{1
K
*V
*W
*Y
T
2
10
8
9
13
15 16
F
J
M
N
2
S
W*
*B
* Model 239081
1
1
1
11
inlet port test port
T
FC

14 308702
Technical Data
Maximum working pressure 60 psi (0.41 MPa, 4.1 bar). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air line connection quick-connect male air line fitting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inlet size 3/4 npt. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Actuator valve inlet size 3/4 npt. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Actuator valve outlet size 3/4 npt. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wetted parts
Model 239080 polypropylene, TFE-coated SST, TFE-coated brass, buna-N, PVC. . . . . . . . . . . . . . . . . . . . . . . . . . .
Model 239081 SST, TFE-coated SST, TFE-coated brass, buna-N. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Non-wetted external parts
Model 239080 polypropylene, thermoplastic, aluminum, brass, painted mild steel. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model 239081 acetal, thermoplastic, aluminum, brass, painted mild steel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weight
Model 239080 18 lb (8.2 kg). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model 239081 23 lb (10.4 kg). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions
Model 239081 shown
23.5 in.
(597 mm)
highest dimension
3/4 npt
3/4 npt
(inlet and outlet)
12 in.
(330 mm)
diameter
14 in.
(356 mm)
widest dimension
06843

308702 15
Notes

16 308702
Graco Standard Warranty
Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the
date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited
warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment
determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in
accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by
faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or
substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of
Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture,
installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for
verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The
equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect
in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and
transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT
NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other
remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any
other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the
date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection
with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured
by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide
purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment
hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract,
breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings
entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties
reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures
judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
Graco Information
TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers
to identify the distributor closest to you:
1–800–328–0211 Toll Free
612–623–6921
612–378–3505 Fax
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
MM 308702
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
http://www.graco.com
PRINTED IN U.S.A. 308702 11/1996 Rev. 02/2006