Mounting / operation instructions
Montage / Betriebsanleitung
Montaža / Navodila za uporabo
Street luminaire
Strassenleuchte
Javna razsvetljava
Version: 3.0
AEROLITE
LSL S│M│L
ECO S│M│L
S
M
L
22
MOUNTING INSTRUCTION FOR AEROLITE FAMILY MONTAGEANLEITUNG FÜR DIE AEROLITE FAMILIE
MONTAŽNA NAVODILA ZA DRUŽINO AEROLITE www.grahlighting.com
This product must be mounted and installed in accordance with the
applicable installation code by qualied personnel familiar with the
construction and operation of the product and the hazards Involved.
Consult a qualied electrician to ensure correct branch circuit conductor (Min
90°C supply conductors).
Control terminals are separated from live parts by basic insulation only. The
installer has to secure safe insulation of control parts.
Luminaires which are of protection class II, are obliged to have installed an
additional surge protection device (SPD) of type 2 or 3 (T2 or T3 as per IEC/
EN61643-11) in their close vicinity (pole or luminaire) and another one of T1 (per
IEC/EN61643-11) for the whole branch of luminaires, installed in the electrical
cabinet, supplying that branch.
The luminaire should be positioned so that prolonged staring into the luminaire at
a distance closer than 2,68 m is not expected.
Grah Lighting d.o.o. will not be liable for any direct or indirect damages and/or
injuries resulting from not complying to this manual.
This installation manual has to be kept safe in case of any future maintenance of
the luminaire.
Die Installation und der Anschluss des Produktes darf nur durch die
entsprechend qualizierte Person ausgeführt werden, die mit den
Eigenschaften und der Funktion wie auch mit den möglichen Risiken
des Produktes vertraut ist. Die Montage muss auch nach den Aktuellen normen
ausgeführt werden. Bei der Auswahl vom Leitertyps der Anschlussleitung (min.
90°C) erkundigen Sie sich bei einem qualizierten Elektrofachmann.
Die Klemmen sind von Bassesteilen die unter Stromspannung stehen nur mit
einer Basisisolation getrennt. Der Installateur muss, für den Isolation schütz vom
Steuersätzen die an die diese Klemmen angeschlossen sind sorgen.
Leuchten der Schutzklasse II müssen in deren Nähe (Mast oder Leuchte)
einen Überspannungsschutz (Surge Protection Device, SPD) des Typ T2 oder
T3 installiert haben. Eine SPD des Type T1 muss auch im Elektroschaltkasten
installiert werden, aus dem die komplette Linie der Leuchten mit Strom versorgt
wird.
Die Position der Leuchte muss so ausgelegt werden, das der erwarteter direkter
Blick in die Leuchte nicht näher ist als 2,68 m.
Grah Lighting d.o.o. übernehmt keine Verantwortung für direkte oder indirekte
Schäden, die durch nicht Beachtung der Montageanleitung verursachte werden.
Diese Montageanleitung muss für mögliche spätere Wartung sicher aufbewahrt
werden.
Montažo in priklop tega izdelka lahko opravi le strokovno usposobljena
oseba, seznanjena s sestavo in delovanjem izdelka, ter z morebitnimi
tveganji, ki pri tem nastanejo. Hkrati mora biti opravljena v skladu
z veljavnimi normami. Za izbor tipa vodnika priključne veje (min. 90 °C) se
posvetujte s strokovno usposobljenim elektrikarjem.
Krmilne sponke so od delov pod mrežno napetostjo ločene le z osnovno izolacijo.
Instalater mora poskrbeti za zadostno izolacijo krmilnih sklopov, priključenih na
te sponke.
Svetilke zaščitnega razreda II morajo imeti v svoji bližini (v stebru ali v svetilki
sami) vgrajeno prenapetostno zaščito tipa 2 ali 3 (T2 ali T3 po IEC/EN61643-11),
ter dodatno še eno T1 (po IEC/EN61643-11) vgrajeno v električno omarico, za
celotno vejo svetilk, ki se napaja iz te omarice.
Svetilka mora biti postavljena tako, da dalj časa trajajoče strmenje v svetilko z
razdalje manjše kot 2,68 m ni pričakovano.
Grah Lighting d.o.o. ne odgovarja za nobeno neposredno ali posredno povzročeno
škodo in/ali poškodbe, povzročeno zaradi neupoštevanja teh navodil.
Zaradi morebitnega kasnejšega vzdrževanja svetilk je potrebno montažna
navodila skrbno shraniti.
Control terminals are separated from live parts by
basic insulation. The installer has to secure save
Insulation of control parts!
SML
13
4 5
Ø60 mm
Ø60 mm Ø76 mm
106 mm
106 mm 106 mm
TOOLS / WERKZEUGE
BRACKET / HALTER
MOUNTING HEIGHT / MONTAGEHÖHE
720 mm
465 mm
139 mm
430 mm
200 mm
130 mm
430 mm
310 mm
135 mm
Aw=0,023 m2
Aw=0,024 m2
Aw=0,043 m2
max = 2,5 kg (LSL)
max = 2,6 kg (ECO)
max = 3,5 kg (LSL)
max = 3,7 kg (ECO)
max = 6,8 kg (LSL)
max = 7,6 kg (ECO)
kg
kg
kg
AEROLITE LSL/ECO S
AEROLITE LSL/ECO M
AEROLITE LSL/ECO L
5 Nm
Ø 6 - 13 mm
120 mm
40 mm
0,5 mm2 - 2,5 mm2
(AWG 14 - AWG 20)
8 mm
13
12 Nm
15 Nm
1
2
4
3 A CLASS l
L
N
LST
L
N
LST
L
N
LST
3 N 1 2 3 N 1 2
3 N 1 2
3 N 1 2
L
N
LST
3 N 1 2
L
N
+
-
3 N 1 2
L
N
+
-
L
N
LST
L
N
LST
L
N
LST
3 N 1 2 3 N 1 2
3 N 1 2
3 N 1 2
L
N
LST
3 N 1 2
L
N
+
-
3 N 1 2
L
N
+
-
DC 1-10V
☼=10-100%
DC 1-10V
☼=10-100%
LST(230V) = 100% LST(230V) = 100%LST(230V) = 50% LST(230V) = 50%
IEC / EN 61140 3 B CLASS ll IEC / EN 61140
5
20 Nm
4x M8 x 20 mm
4 5 ANGLES (optional) / NEIGUNGEN (optional)
15 Nm
13
For bracket Ø60 mm and Ø76 mm
Side 1 (from 0 to +15°)
Side 2 (from 0 to -15°)
4
12 Nm
0 +5
+10 +15
0
-5
-10 -15
ON / OFF ON / OFF
50% dimming scheme 50% dimming scheme
100% dimming scheme 100% dimming scheme
USA GB CDN
Installation /
maintenance
only by qualified
personnel.
DE A CH
Installation / Wartung
kann durch entsprechend
qualifizierte Person
eingeholt werden.
SLO
Montažo/vzdrževanje
lahko opravi le strokovno
usposobljena oseba.
F B
Les opérations
d’installation et
d’entretien doivent ętre
effectuées exclusivement
par des personnes
qualifiées.
HR BIH
Montažu/održavanje
mora vršiti odgovarajuće
osposobljena osoba.
SCG
Montažu/održavanje
može da obavi samo
stručno osposobljena
osoba.
S
Montering akötsel endaat
av fackfolk
I
Montaggio /
Manutenzione solo per
mezzo di Personale
specializzato.
TR
Montaj ve Bakim sadece
yetkili personel taranndan
yapilmalidir.
H
A szerelést /
karbantártast csak
szakszemélyzet
végezheti.
N
Monteres kun av
fagpersonell.
NL
Montage / service alleen
door vakkundig
personeel.
R
Монтаж / обслуживание
только специалистами.
P
Montagem/Manutençăo
efectuada unicamente por
pessoal técnico
especializado.
SK CZ
Montáž a údržba může
být prováděna výhradně
odbornou pracovní silou.
POL
Montaż / konserwacja
tylko przez fachowy
personal.
E
El montaje y
manteminiento lo
efectuaran únicamente
los técnicos
especializados.
GENERAL SAFETY INFORMATION / SICHERHEITSHINWEIS
GRAH Lighting d.o.o.
Zadružna ul. 6
SI-2310 Slovenska Bistrica
Slovenija
Tel.: +386 (0)82 801 424
Fax: +386 (0)82 801 402
Mail: [email protected]
www.grahlighting.com
Modification and opening of the device is not allowed!
Eingriffe und öffnen des Gerätes verboten!
4 - 10 m
8 - 15 m
3 - 6 m

This manual suits for next models

5

Popular Lantern manuals by other brands

ORIUM Alicia instruction manual

ORIUM

ORIUM Alicia instruction manual

Sulion NEKO 112262 manual

Sulion

Sulion NEKO 112262 manual

delviro energy ZOOM installation manual

delviro energy

delviro energy ZOOM installation manual

FastTan SunBoard XTT Care, use and installation instructions

FastTan

FastTan SunBoard XTT Care, use and installation instructions

Argos G03131P Care & instruction manual

Argos

Argos G03131P Care & instruction manual

SLOS LAKY060 user guide

SLOS

SLOS LAKY060 user guide

DMK OLSO R Installation and operating instructions

DMK

DMK OLSO R Installation and operating instructions

Kichler Lighting Montego 49679WHRLED manual

Kichler Lighting

Kichler Lighting Montego 49679WHRLED manual

Emos P4525 manual

Emos

Emos P4525 manual

Chalmit Protecta Series Installation, operation and maintenance instructions

Chalmit

Chalmit Protecta Series Installation, operation and maintenance instructions

Steelcase Dash manual

Steelcase

Steelcase Dash manual

Stahl 6018 Series operating instructions

Stahl

Stahl 6018 Series operating instructions

SLV Elektronik 230862 operating manual

SLV Elektronik

SLV Elektronik 230862 operating manual

Smith-Victor EZ Lantern user manual

Smith-Victor

Smith-Victor EZ Lantern user manual

ETC ETC 405 user manual

ETC

ETC ETC 405 user manual

IKEA FRYEBO manual

IKEA

IKEA FRYEBO manual

Sealite SL-C510 Installation & service manual

Sealite

Sealite SL-C510 Installation & service manual

KYOWA KW-9114 instruction manual

KYOWA

KYOWA KW-9114 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.