OPERATION
1: Press the “POWER” switch, the display should show zeros but may not as there may be a EMF field in your
location. The instrument will display the strongest source in the Immediate area . The Built in sensor is located
in the top of the unit. Moving the unit about can minimize some interference.
❇❇
❇❇
❇Note: because of the environment and possible electromagnetic interference, the instrument can have non
zero reading, the instrument is not faulty.
2: While holding the instrument, move closer to the suspected source(s) of the electromagnetic radiation. The
unit will display the actual values of radiation from the equipment unless the value is less than the minimum
machine reading of 0.1 μW/cm2.
❇❇
❇❇
❇Note: In high Voltage or Power locations, Pay close attention to distance for exposure and safety.
3: “Data Hold” button is pressed, the top of the screen, above the numeric reading, displays “H” and the
displayed value is locked. Press “Data Hold” button again to resume testing.
4: “Max Hold” button is pressed, the top of the screen above the numeric reading, shows “MAX”. The instrument
will display a value that will only change when a higher peak is sensed. This function is used to detect maximum
field location in a specific environmental areal.
5: Low Battery symbol ( ) will appear at the top left of the display when the battery runs low. Please
replace the battery.
RESOURCES
The radiation protection regulations (GB8702-88)
Environmental impact assessment methods and criteria of electromagnetic radiation (HJ/T10.3-1996)
RECOMENEDED:
Note: The following information is for user’s reference only, and does not have the force of law.
Professional environmental radiation exposure limit of less than 50 μW/cm2for 8 consecutive hours of daily.
General Public environmental exposure to electromagnetic radiation of less than 40μW/cm2
TECHNICAL SPECIFICATECHNICAL SPECIFICA
TECHNICAL SPECIFICATECHNICAL SPECIFICA
TECHNICAL SPECIFICATIONSTIONS
TIONSTIONS
TIONS
Size: 132mm (l) x69mm (w) x31mm (d)
Weight: 140 g
Display: 3-1/2-digit .38" LCD
Accuracy: 0.1 μW/cm2
Range: 0.1 μW/cm2-199.9 μW/cm2
Alarm threshold: 20.0 μW/cm2
Bandwidth: 50MHz-3700MHz
Sampling time: 0.3 seconds
Sensor head: single-axis (top of the instrument)
Overload: LCD displays “OL”
Operating Temperature:-15OC to+60OC
Operating Humidity: relative humidity <80%
Operating Voltage: 9V (6F22 9V battery)
+_
INSTRUCTION MANUAL