CONTENTS
A FEW WORDS ABOUT YOUR NEW AIR CONDITIONING UNIT.......................................... 1
ELECTRICAL DATA........................................................................................................................ 1
ELECTRIC DIAGRAM .....................................................................................................................2
PACKING LIST ..............................................................................................................................3
PARTS NAME ........................................................................................................................... 4
OPERATION OF WIRELESS REMOTE CONTROLLER.......................................................... 5
CONTROL PANEL ..........................................................................................................................9
INSTALLATION INSTRUCTION .................................................................................................. 10
STEP 1-STICK SPONGE (SEALING STRIP) AND SPONGE ON THE OUTDOOR UNIT .............................................. 10
STEP 2-SELECTING AN INSTALLATION LOCATION & INSTALLING THE ROOF TOP AIR CONDITIONER........... 10
STEP3-MOUNTING OUTDOORUNIT .................................................................................................................................... 14
STEP 4-INSTALLING THE CEILING ASSEMBLY .................................................................................................................. 15
STEP5-ELECTRICAL WIRING ................................................................................................................................................ 16
STEP 6-COMPLETING THE INSTALLATION........................................................................................................................ 17
TROUBLESHOOTING GUIDE ....................................................................................................... 18
ERROR CODE..................................................................................................................................19
NORMAL MAINTENANCE PROCEDURES ................................................................................ 20
SPECIALIST’S MANUAL................................................................................................................. 21
This appliance is not intended for use by persons (including children) with lack of
experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety. Children
should be supervised to ensure that they do not play with the appliance.
This appliance can be used by children aged from 8 years and above with lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved.
Children shall not play with the appliance.
Cleaning anduser maintenance shall not be made by children without supervision.
When refrigerant leaks or requires discharge during installation, maintenance, or
disassembly, it should be handled by certified professionals or otherwise in
compliance with local laws and regulations.

Appliance filled with flammable gas R32.
Before install and use the appliance, read the owner’s manual first.
Before install the appliance, read the installation manual first.
Before repair the appliance, read the service manual first.
THE REFRIGERANT
To realize the function of the unit, a special refrigerant circulates in the system. The
used refrigerant is the fluoride R32, which is specially cleaned. The refrigerant is
flammable and inodorous. Furthermore, it can lead to explosion under certain
conditions. But the flammability of the refrigerant is very low. It can be ignited only
by fire.
Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm
to the ozonosphere. The influence upon the greenhouse effect is also lower. R32
has got very good thermodynamic features which lead to a really high energy effi-
ciency. The units therefore need a less filling.
Appliance filled with flammable gas R32.
Appliance shall be installed, operated and stored in a room with a floor area larger
than 4 m2.
The appliance shall be stored in a room without continuously operating ignition sources .
( for example: open flames, an operating gas appliance or an operating electric heater.)
The appliance shall be stored in a well-ventilated area where the room size corresponds
to the room area as specified for operation.
The appliance shall be stored so as to prevent mechanical damage from occurring.
Ducts connected to an appliance shall not contain an ignition source.
Keep any required ventilation openings clear of obstruction.
Do not pierce or burn.
Be aware that refrigerants may not contain an odor.
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
Servicing shall be performed only as recommended by the manufacturer.
Should repair be necessary, contact your nearest authorized Service Centre.
Any repairs carried out by unqualified personnel may be dangerous.
Compliance
with
national
gas
regulations
shall
be
observed.
Read SPECIALIST’S MANUAL.
WARNING

INSTALLATION PRECAUTION
WARNING:
Observe all governing codes and ordinances.
Do not use damaged or non-standard power cord.
Be caution during installation and maintenance. Prohibit incorrect operation
to prevent electric shock, casualty and other accidents.
Suggested working temperature range: 23 ~ 115℉(-5~46℃). (heating:23~75℉
(-5~24℃ )/cooling:64~115℉(+18~46℃).
Outdoor unit may stop operation, due to various kinds of protection within working
temperature range.
Basic requirement
Installing the unit in the following places may cause malfunction. If it is unavoidable,
please consult the local dealer:
a.
The place with strong heat sources, vapors, flammable or explosive gas, or
volatile objects spread in the air.
b.
The place with high-frequency devices (such as welding machine, medical equipment).
c.
The place near coast area.
d.
The place with oil or fumes in the air.
e.
The place with sulfureted gas.
f.
Other places with special circumstances.
g.
This air conditioner unit is only used for the vehicle without and convex surface
on the top of it.
h.
Prohibit operating this air conditioner unit when starting up the vehicle or when the
vehicle is driving.
i.
Prohibit supplying the power for the air conditioner unit with the vehicle power supply.
Requirement of air conditioner
a.
Air inlet should be far away from obstacles and do not put any objects near air
outlet. Otherwise, it will affect the radiation of heat-removal pipe.
b.
Select a location where the noise and outflow air emitted by the outdoor unit will
not affect neighborhood.
c.
Please try your best to keep far away from fluorescent lamp.
d.
The appliance shall not be installed in the laundry.
Working temperature range
Selection of Installation Location

INSTALLATION PRECAUTION
Safety precaution
1. Must follow the electric safety regulations when installing the unit.
2. According to the local safety regulations, use qualified power supply circuit.
3. For appliances with type Y attachment, the instructions shall contain the
substance of the following. If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified persons in order to avoid
a hazard.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety.
6. Do not put through the power before finish installation.
7. The air conditioner is first class electric appliance.it must be properly grounding
with specialized grounding device by a professional. Please make sure it is always
grounded effectively, otherwise it may cause electric shock.
8. The yellow-green wire or green wire in air conditioner is grounding wire, which
can't be used for other purposes.
9. The grounding resistance should comply with national electric safety regulations.
10. The appliance shall be installed in accordance with national wiring regulations.
11. Specification of fuse on the main board:T3.15AH250V; the maximum current
passes through the fuse can't be more than 3.15A.
Requirements For electric Connection

- 1 -
A FEW WORDS ABOUT YOUR NEW
AIR CONDITIONING UNIT
Thank you for choosing the Recreational Vehicle Air Conditioner.
This manual will supply you with all the information for installation, operation and maintenance.
Take a few minutes to discover how to get the most in cooling comfort and economic operation
from your new air conditioner.
Please keep this manual well for future reference.
An all-pole disconnection switch having a contact separation of at least 3mm in all poles should
be connected in fixed wiring.
Including an air switch with suitable capacity, Air switch capacity:25A.
Air switch should be included magnet buckle and heating buckle function, it can protect the
circuit-short and overload.
ELECTRICAL
DATA
1.
All wiring must be complied with local and national electrical codes. All wiring
must be installed by qualified electricians. If you have any questions about the
following instructions, contact a qualified electrician.
2.
Check the available power supply and resolve any wiring problems before installing
and operating this unit.
3.
This air conditioner is designed to operate from a 115V AC, 60Hz, 1 Phase
power supply.
4.
The wiring diagrams are located on the cover of the control box. The assembly unit
wire diagrams are located on the ceiling panel.
5.
The electric schematic diagram are subject to change without notice. Please refer
to which one on the unit.

- 2 -
ELECTRIC DIAGRAM
Ceiling Assembly
AP1
RT1 ROOM
DISPLAY
BOARD
SWING-L SWING-R
M1 M2
ROOM
DISP1
WIFI
AP2
MODULE
WIFI
SENSOR
CONNECTOR
YEGN
WH
BK
TERMINAL
BLOCK
STEPPING STEPPING
MOTOR MOTOR OPTIONAL L BK(BN) L
N WH(BU) N
GN(YEGN)
G G POWER
Roof Top Air Conditioner
OUTDOOR UNIT

- 3 -
PACKING LIST
Packing List of Indoor Unit
Packing List of Outdoor Unit
LED
owner’s manual
Sponge(air duct)
remote controller
battery
(AAA 1.5V)
Double-sided
gummed paper
Sunk screw
(remote controller holder)
Screw cap
use in
indoor
(bottom)
use in
outdoor
(upper)
Tapping screw
Plate of air vent
Bolt sub-assy
M8X135
Remote controller holder
Sponge (sealing strip)
Sponge

- 4 -
PARTS NAME
Indoor Unit
Filter sub-assy
L
L
E
E
D
D
(Display content or position may be different from above
graphics, please refer to actual products)
remote controller
Outdoor Unit
Outer case
Air-in grille
Chassis
Drainage outlet
NOTICE:
Actual product may be different from above graphics, please refer to actual
products.

- 5 -
OPERATION OF WIRELESS REMOTE CONTROLLER
Buttons on remote controller Introduction for icons on display
screen
Set fan speed
Send signal
Operation mode
Auto mode
Cool mode
Dry mode
Fan mode
Heat mode
Sleep mode
Light
X-FAN function
Indoor ambient temp.
Clock
Set temperature
WiFi function
Set time
TIMER ON / TIMER OFF
Up & down swing
Child lock
LED

- 6 -
NOTE
●Fan Speed "
Fan Speed "
for some models.
" is unavailable for some models,
" is the same with Fan Speed "
"
●Under AUTO speed, air conditioner will select proper
fan speed automatically according to factory default
setting.
●
AUTO speed is only available for some models.
●It's low fan speed under dry mode.
Introduction for buttons on
remote controller
This button is used for setting Fan Speed in the
sequence that goes from AUTO,
,
,
,
to
, then back to Auto.
Press this button to turn on the unit. Press this button
again to turn off the unit.
Press this button to select your required operation
mode.
AUTO
COOL
DRY
FAN
HEAT
●
When selecting auto mode, air conditioner will
operate automatically according to ambient tem-
perature. Set temperature can't be adjusted and
will not be displayed as well. Press "FAN" button
can adjust fan speed.
●
When selecting cool mode, air conditioner will
operate under cool mode. Press "+" or "-"
button to adjust set temperature. Press "FAN"
button to adjust fan speed.
●
When selecting dry mode, the air conditioner
operates at low speed under dry mode. Under
dry mode, fan speed can't be adjusted.
●
When selecting fan mode, the air conditioner will
Press "+" or "-" button once increase or decrease
set temperature 1℉(℃). Holding "+" or "-" button, 2s
later, set temperature on remote controller will
change quickly. On releasing button after setting is
finished, temperature indicator on indoor unit will
change accordingly. (Temperature can’ t be adjust-
ed under auto mode)
When setting TIMER ON, TIMER OFF or CLOCK,
press "+" or "-" button to adjust time. (Refer to
CLOCK, TIMER ON, TIMER OFF functions).
Press this button to select submenu function and
then press "SET" button to set the function
status of submenu. The submenu can be select-
ed circularly as follows:
only blow fan, no cooling and no heating. Press
"FAN" button to adjust fan speed.
●
When selecting heat mode, the air conditioner
operates under heat mode. Press "+" or "-"
button to adjust set temperature. Press "FAN"
button to adjust fan speed.
blank
No Setting
TIMER
ON
TIMER
OFF
NOTE
●This is a general use remote controller . It could be
used for the air conditioner with multifunction. For the
functions which the model doesn't have, if press the
corresponding button on the remote controller, the
unit will keep the original running status.
●After putting through the power, the air conditioner
will give out a sound. Power indicator " " is ON.
After that, you can operate the air conditioner by
using remote controller.
●Under on status, pressing the button on the remote
controller, the signal icon " " on the display of
remote controller will blink once and the air condition-
er will give out a sound, which means the signal has
been sent to the air conditioner.
NOTE
●For preventing cold air, after starting up heat mode,
indoor unit will delay 1~5 minutes to blow air (Actual
delay time depends on indoor ambient temperature).
●Set temperature range from remote controller:
61~86℉(16-30℃).
●This mode indicator is not available for some models.
●
Cooling only unit won't receive heat mode signal. If
setting heat mode with remote controller, press
"" button can't start up the unit.
FAN button
button
MODE button
- / + button
MENU button
NOTE
●Some menu’s function may be unavailable under
different models.

- 7 -
When selecting light function, light icon "
"
flashes for 5s; press "SET" button within 5s to
turn off display light on indoor unit and " " icon
on remote controller disappears. Press “SET”
button again within 5s to turn on display light and
"" icon is displayed.
When selecting sleep function, sleep icon "
"
flashes for 5s; press " SET " button within 5s to
turn on sleep function and "
" icon is displayed
on remote controller. Press " SET " button again
within 5s to turn off sleep function and "
" icon
disappears.
When selecting up & down swing function, up &
down swing icon "
" flashes for 5s; press
"SET" button within 5s to select up & down swing
angle. Fan blow angle can be selected circularly
as below:
no display
(horizontal louvers stops
at current position)
TIMER ON function can set the time for timer on.
Under TIMER ON function status," " icon disap-
pears and the word "ON" on remote controller
blinks. Press "+" or "-" button to adjust TIMER ON
setting. After each pressing "+" or "-" button
TIMER ON setting will increase or decrease 1min.
Hold "+" or "-" button, 2s later, the time will change
quickly until reaching your required time.Press
"SET" button to confirm it within 5S. The word
"ON" will stop blinking.
Cancel TIMER ON: Press "MENU" button to
TIMER ON function and the characters "ON" flash-
es on the remote controller; press "SET" button
until the characters "ON" disappears.
TIMER OFF function can set the time for timer off.
Under TIMER OFF function status,"
" icon
disappears and the word "OFF" on remote control-
ler blinks. Press "+" or "-" button to adjust TIMER
OFF setting. After each pressing "+" or "-" button
TIMER OFF setting will increase or decrease 1min.
Hold "+" or "-" button, 2s later, the time will change
quickly until reaching your required time, press
"SET" button to confirm it within 5S. The word
"OFF" will stop blinking.
Cancel TIMER OFF: Press "MENU" button to
TIMER OFF function and the characters "OFF"
flashes on the remote controller; press "SET"
button until the characters "OFF" disappears.
When selecting ambient temperature display
function, icon "
" flashes for 5s; press "SET"
button within 5s to select ambient temperature
display on or off. After setting
function on, the
"
" icon will be displayed on remote controller
and you can see indoor ambient temperature on
indoor unit's displayer for a few seconds.
CLOCK function can se
i
t
nd
c
i
l o c
o
k
r
time. Under
CLOCK function status, "
" icon on remote con-
troller will blink. Press "+" or "-" button within 5s to
set clock time. Each pressing of "+" or "-" button,
clock time will increas e or decrease 1 min. If hold
"+" or "-" button , 2s later, time will change quick-
ly. Release this button when reaching your
required time, press "SET" button to confirm it
within 5S. The "
" icon will stop blinking.
Press this button can turn on or turn off the LED light
on the panel.
NOTE
●This function is only available for some models.
Ambient temperature display function
TIMER ON function
Light function
NOTE
●This function is only available for some models.
Sleep function
up & down swing function
NOTE
●This function is only available for some models.
TIMER OFF function
CLOCK function
LED button

- 8 -
Under COOL or HEAT mode, press this button to
turn to quick COOL or quick HEAT mode. "
"
icon is displayed on remote controller. If start this
function, the unit will run at super-high fan speed
to cool or heat quickly so that the ambient tem-
perature approaches the preset temperature as
soon as possible.
Replacement of batteries in
remote controller
battery
signal sender
reinstall
remove
Cover of battery box
Function introduction for
combination buttons
1. Press the back side of remote controller
marked with " ", as shown in the fig, and then
push out the cover of battery box along the
arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and
make sure the position of "+" polar and "-" polar
are correct.
3. Reinstall the cover of battery box.
Press "+" and "-" simultaneously to turn on or
turn off child lock function. When child lock func-
tion is on, "
" icon is displayed on remote control-
ler. If you operate the remote controller, the "
"
icon will blink three times without sending signal to
the unit.
Under OFF status, press "-" and "MODE" buttons
simultaneously to switch temperature display
between
℃
and
℉
.
Press "MODE" and "TURBO" button simultane-
ously to turn on or turn off WiFi function. When
WiFi function is turned on, the "WiFi" icon will be
displayed on remote controller; Long press
"MODE" and "TURBO" buttons simultaneously
for 10s, remote controller will send WiFi reset
code and then the WiFi function will be turned on.
WiFi function is defaulted ON after energization
of the remote controller.
Child lock function
TURBO button
NOTE
●Fan Speed "
Fan Speed "
for some models.
" is unavailable for some models,
" is the same with Fan Speed "
"
NOTICE
●
During operation, point the remote control signal
sender at the receiving window on indoor unit.
●
The distance between signal sender and receiving
window should be no more than 8m, and there
should be no obstacles between them.
●
Signal may be interfered easily in the room where
there is fluorescent lamp or wireless telephone;
remote controller
should be close to indoor unit
during operation.
●
Replace new batteries of the same model when
replacement is required.
●
When you don't use remote controller for a long time,
please take out the batteries.
●
If the display on remote controller is fuzzy or there's
no display, please replace batteries.
Temperature display switchover function
WiFi function
NOTE
●This function is only available for some models.

- 9 -
CONTROL PANEL
Note: If the remote controller is missing, operate on the control panel.
2 1
TURBO
HIGH
LOW
AUTO
4
Not available for cooling
only model
3 6 4 5
ON/OFF button
Operation starts when pressing this button, and
stops when pressing this button again.
SWING button
Activate the automatic air swing function.
FAN SPEED button
Select the fan speed AUTO,LOW, HIGH and
TURBO in sequence.
Note:
1.
When setting fan mode by the remote
controller, turbo function is unavailable for the
fan mode. Turbo function can only be set by
the buttons on the control panel.
2.
If the unit is without medium fan speed,
when receiving medium fan speed command
from the APP or remote controller, the unit will
operate at high fan speed.
(+/-) / TIMER button
Press the + button to increase the set(operating)
temperature of the unit,and press the - button to
decrease the set(operating) temperature of the
unit.the temperature setting range is
from 61~86℉( 16-30℃) .Press
TIMER button,then press +/- to
increase and decrease the time
setting. If the time setting is nomore
than 10 hours,the increment/
decrement is 0.5 hour by each press,if
more than 10 hours, the increment/
decrement is 1 hour by each press.
The time setting range is 0.5~24 hours.
MODE button
Select the operation mode,COOL,DRY,
FAN, HEAT .
FILTER CHECK indicator
This feature is a reminder of cleaning
the air filter(normal maintenance) for
more efficient operation. The light will
turn on automatically after the fan
works more than 250 hours.
If the light is on, turn off and power off
the unit, take the air filter out and
clean it, then re-install the air filter,
power on and turn on the unit, the
light will still be on, press FILTER
CHECK button,the light will turn off.
1
2
3
4
5
6

- 10 -
INSTALLATION
BEFORE INSTALLATION
Test run the unit with proper power supply. Refer to the operation instruction section in the Owner’s
Manual Operation & Installation. Make sure all the controls operate correctly then disconnect the
power supply of the unit.
WARNING
1.Moving parts may cause personal injury. Be careful when test the unit. Do not operate the
unit with exterior cover removed.
2.Outdoor unit can't be installed at the low recess of the roof of vehicle. It must be mounted a
the flat surface on the roof of vehicle to make sure the rain, car-washing water, condensate
water, etc. can be drained smoothly. No water is allowed to be accumulated around the
outdoor unit; otherwise, it will cause malfunction or safety hazards as the water will pour into the
air conditioner.
1. Before sticking, clean up the sundries
at the sticking position (as shown in
Figure 1) of the chassis of the outdoor
unit to ensure that the sticking position
is clean;
2. Take out one piece of sponge (sealing
strip) and one piece of sponge from the
accessories, and tear off the paper on
the glue surface and align at the edge of
the position as shown in Figure 1 to stick
the sponge.
If the sponge (sealing strip) is damaged
or not stuck on the proper position, you
must replace it with a new one and stick
it properly;
3. Check whether the sponge (sealing strip)
and the sponge are tightly adhered, and
ensure that they will not fall off.
Sticking position
of sponge
(sealing strip)
Sticking position of
one piece of sponge
Figure 1
STEP 2-SELECTING AN INSTALLATION LOCATION &
INSTALLING THE ROOF TOP AIR CONDITIONER
Your air conditioner has been designed for use in recreational vehicles.
Check the roof of the vehicle to determine if it can support both the roof top unit and the ceiling
assembly without additional support. Make sure the interior ceiling mounting area will not
interfere with existing structures.

- 11 -
Once the location for your air conditioner has been determined. A reinforced and framed roof.
Hole must be cut (if there is no hole, please refer to CASE B) or you may use existing vent
holes (See CASE A).
CASE A.
If a roof vent is already present in the desired mounting location for the air conditioner the
following steps must be performed:
1.Remove all screws which secure the roof vent to the vehicle. Remove the vent and
any additional trim. Carefully remove all chalking from around the opening so the surface
is clear.
2.It may be necessary to seal some of the old roof vent mounting screw holes which may
fall outside of the air conditioner basepan gasket.
3.Examine the roof opening size, if the opening is small than (14-1/4”)x(14-1/4”), the
opening must be enlarged.
CASE B.
If a roof vent opening is not used,a new opening(see figure 1-1)will be cut into the vehicle roof.
A matching opening will also have to be cut into the interior vehicle ceiling,be careful when
cutting the ceiling opening because if the ceiling opening is carpeted,snagging could occur. After
the opening in the roof and interior ceiling are the correct size,a framed support structure must
be placed between the exterior roof top and interior ceiling.The reinforced framed structure must
follow the following guidelines:
1. It must be capable of supporting both the
weight of the roof top air conditioner and
the interior ceiling assembly.
2. It must be capable of holding the roof outer
surface and interior ceiling apart and
supporting them, so that when the roof top
air conditioner and ceiling assembly are
bolted together,no collapsing occurs. A
typical support frame is shown in Figure 1-1 .
3. There must be an opening through the
frame for the power supply wiring.Route
the supply wiring through the frame at the
same time the support frame is being
installed.
Hole for
Wires
Figure 1-1

- 12 -
ove Level 5°Max
CAUTION
1. The roof top air conditioner must be mounted on a level plane from front to rear and side to
side when the vehicle is parked on a level plane. Figure 2 shows maximum allowable degrees
that the unit can be mounted above or below level.
2. If the roof of the vehicle is sloped (not level) such that the roof top air conditioner cannot be
mounted within the maximum allowable degree specifications, an exterior leveling shim will
need to be added to make the unit level. A typical leveling shim is shown in Figure 3.
3. Once the roof top air conditioner has been leveled, some additional shimming may be
required above the interior ceiling assembly. The roof top air conditioner and the interior
ceiling assembly must be square with each other before they are secured together.
4. After the mounting hole area is properly prepared, remove the carton and shipping pads from
around the roof top air conditioner. Carefully lift the unit on top of the vehicle. Do not use the outer
plastic shroud for lifting. Place the roof top air conditioner over the prepared mounting hole.
5. The front section of outdoor unit of air conditioner must be in the same direction as the vehicle,
which is useful for reducing wind resistance.
Note: Try you best to put the unit on the horizontal surface for operation. The unit can only operate for a short
time at the maximum sloping angle of 5° for preventing water leakage.
Level
Level
Level
Above or below
Ab
Level 5°Max
Below Level 0°Max
Figure 2
Above Level 5°Max
Below Level 0°Max
Level
Height Varies to Make Unit Level
Figure 3

- 13 -
NOTE AIR CONDITIONER DIMENSIONS (ROOF OF UNIT)
42.4”
14-1/4”
4.2”
(24”)
28.3”
Figure 4
(14-1/4”)x(14-1/4”)
OPENING

- 14 -
STEP 3-MOUNTING OUTDOOR UNIT
1.Open the package and take out the outdoor
unit.
1) When taking out the outdoor unit after
unpacking, do not lift the air outlet grille at
the back of outer case
(see Figure 4-1).
2.Fix the outdoor unit at the roof of vehicle and
then drill holes.
1) Place the outdoor unit at the roof of vehicle;lift
the outdoor unit and then place the outdoor unit
after drilling holes at the roof of vehicle.
Do not drag the outdoor unit. Otherwise, the
seal may fall off(see Figure 4-2).
Figure 4-1
Figure 4-2

- 15 -
STEP 4-INSTALLING THE CEILING ASSEMBLY
Make sure that you have properly matched the roof top air conditioner and interior ceiling assembly.
Caution before tightening bolts:
1.The applicable thickness of vehicle roof ranges from 1.2”~3.1”.
2.Before tightening bolts, screw in the four bolts manually and prohibit screwing forcibly.
3.When screwing bolts, you can use automatic tool. Do not tighten one bolt completely and then
tighten other bolts, in order to prevent sticking of screw thread.
4.The max torque for tightening ranges from 2.3Nm~2.5Nm.
The following step by step instructions must be performed in the following sequence to ensure proper
installation.
1. Carefully take the ceiling assembly out of
the carton(The remote control packed with
the ceiling assembly).
2. Remove the ceiling grille from the ceiling
assembly.
Before the ceiling assembly can be
mounted to the roof top air conditioner, the
fabric duct collar must be fastened to the
basepan of the roof top air conditioner with
4 screws by upper duct plate (see Figure 5-
2、Figure 6-1、Figure 5、Figure 5-1).
Before lifting the ceiling assembly, pull the
4. fabric duct collar so it hangs out of the way
and does not get caught under the ceiling
assembly frame.
Secure the ceiling assembly frame to the roof
top air conditioner with the mounting bolts
(see Figure 5).You must start (thread) the
mounting bolts by hand to avoid cross-
threading. DO NOT START THE MOUNTING
BOLTS WITH AN AIR GUN.The mounting
bolts should be tightened, process is
completed when the basepan gasket has
been evenly compressed.
Set the fabric air duct into the duct opening
of installation plate sub-assy and cut off four
corner of fabric air duct. Because the
thickness of vehicle top is different, the
distance between the opening and the
installation plate sub-assy is shown in figure
6.
Fasten each side of the fabric duct with fitting
the bottom duct plate to the ceiling assembly
frame with 4 screws (see Figure 6).Trim any
excess fabric that may extend beyond edge
of bottom duct plate.
5
3
F
ig
ig
u
re
re
5
-1
Figure 5-1
6
7
This manual suits for next models
2
Table of contents
Popular Automobile Accessories manuals by other brands

Directed
Directed Directechs DB3 installation guide

Subaru
Subaru J1010FN800 installation manual

Jaeger
Jaeger J05252127 Fitting instructions

Whelen Engineering Company
Whelen Engineering Company CEM8 installation guide

BURY
BURY Take&Talk Universal Installation and operating manual

Classic Accessories
Classic Accessories Overdrive PolyPro 3 Deluxe manual