Green GPM-315 User manual

48 x 105 x 85
GPM-315
All dimensions are in mm
INTRODUCTION
FRONT VIEW
BACK VIEW PANEL CUTOUT
FOR 0-10 VDC FOR 4-20 mA
MANUFACTURER
PRECAUTION FOR SAFE USE
NOTE:
F
1. Our company shall not be liable for any damages, as described
below, caused to both any users and third parties
a) Damages caused by the result of operation of the product.
b) Damages caused by any defects in the product which are
unpredictable for us.
2. The content in this manual are subject to change without any
notice. If you have any suggestion on the matter,
Thank you very much for purchasing this product GPM-315.
Please read the instruction manual carefully for the full usage of
this product
This Product has passed various quality tests before despatch.
Please check however, at the time of arrival, its model code
and its appearance and ensure that all the contents are provided
and there are no faults, damage etc, to the module. Please also
ensure that the model code ,which is labeled on the module,
is identical to the one you ordered.
GREEN MICROELECTRONICS INDIA PVT. LTD.
green@green .inelectronics www.greenelectronics.in
PROCESS VALUE INDICATOR
(4) Separate the input signal devices, input signal cables
and the product from the source
cables producing noise
(5) The supplied power voltage and load must be within the
rated and specified ranges.
(6) Do not use where the water or oil splatter on the Product.
(7) Install a switch or circuit breaker that allows the operator
to immediately turn off the power
(1) Use and store the Product within the specified
ambient temperature and humidity ranges.
(2) Do not use the product in location subject to vibrations
or shocks. Using the product in such location over a long
period may result in damage due to stress.
(3) Do not use the product in locations subject to dust,
corrosive gases, or direct sunlight
of noise or high - tension
V2.1
SPECIFICATIONS
In the pack
1.5 VA
GPM-315
45 x 90 Cutout
Red LED
Red LED
24 VDC
170 grams
35 to 85 % RH
-10 to 55 c
-25 to 65 c
Power consumption ( Without Load )
Input Low Value 0 for 0-10V, 0-20mA (or) 20 for 4-20mA
Input High Value 100 for 0-10V, 0-20mA & 4-20mA
Model
Mounting Cutout dimension
Supply voltage
Weight
Dimension ( L x W x D )
Ambient temperature
Ambient humidity
Storage temperature
Output Indication ( LOW, V LOW, PASS, HIGH & V HIGH )
Alarm indication ( LOW, V LOW, PASS, HIGH & V HIGH )
Range
Source Input
Outputs
Output Voltage & Current
User Programming
0-10V or 4-20mA
9999 Counts
Selection
Display
Open - Voltage and Close - Current
Six Digits, 0.4 inch seven segment LED display
Very Low, Low, Pass, High & Very High
5 (Very Low, Low, Pass, High & Very High)
5 PNP Transistor (Very Low, Low, Pass, High & Very High)
LED Indications
Set Points
24 VDC Upto 50mA
3 Keys & LED Display
Function Process Monitoring and Alarm
Operating voltage range + / -10% from the rated voltage
11
99
22
33
44
10 10
55
11 11
12 12
13 13
66
77
88
14 14
15 15
16 16
SUPPLY SUPPLY
0 - 10
VDC
0 - 10
VDC
24 VDC 24 VDC
4 - 20
mA DC
4 - 20
mA DC
0 V 0 V
SELECTION
OPEN FOR
0-10 VDC
SELECTION
SHORT FOR
4-20 mA
SELECTION SELECTION
V HIGH
ALM
V HIGH
ALM
HIGH
ALM
HIGH
ALM
PASS PASS
V LOW
ALM
V LOW
ALM
LOW
ALM
LOW
ALM
0 V
COM.
FOR O/P
0 V
COM.
FOR O/P
SUPPLY
24 VDC
SUPPLY
24 VDC
0-10 VDC
Source
4-20 mA
Source
24 VDC PNP OUTPUT
PNP OUTPUT, 24 VDC
24 VDC PNP OUTPUT
PNP OUTPUT, 24VDC
24 VDC PNP OUTPUT
PNP OUTPUT, 24 VDC
24 VDC PNP OUTPUT
PNP OUTPUT, 24VDC
24 VDC PNP OUTPUT
PNP OUTPUT, 24 VDC
CIRCUIT DIAGRAM
Please do not hesitate to contact us.
SELECTION TERMINAL 4 & 5 :
OPEN - VOLTAGE SOURCE (0-10 VOLTS)
CLOSE - CURRENT SOURCE (4-20 A)m
GREEN
GPM - 315 PROCESS VALUE INDICAT0R
SET
V LOW ALM LOW ALM PASS HIGH ALM V HIGH ALM
75
75
45
4548
90
105
48
75
10
1
9
234
10
5
11 12 13
6 7 8
14 15 16
SIDE VIEW
DIMENSIONS
Process Indicator, 2 sets of Mouning Clamps with Screws & Inst., Manual

Operation procedure : SET
Press
before Power ON
Operation level
Power ON
Press SET
for 3 sec
Parameter setting
PV
Press
>
Press SET
Press
>
Press
>
Press
>
Press
>
Input High
Input Low
Decimal
Press SET
Press SET
Press SET
Decide the decimal point
position for the PV Display
Set the Scaling Low using keys
>
>
Set the Input High using keys in %
>
>
Set the input High value 100 for 0-20 mA
Set the input Low value 0 for 0-20 mA
Set the Input Low using keys in %
>
>
Decimal Setting
Scaling High
Scaling Low
Set the input Low value 20 for 4-20 mA
Set the input Low value 0 for 0-10 V
Set the input High value 100 for 4-20 mA
Set the input High value 100 for 0-10 V
Press SET Set the Scaling High using keys
>
>
Press
>
Press
>
Press
>
Very High
High
Low
Very Low
Press
>
Press
>
Press
>
Press SET
Press SET
Press SET
Press SET
Set the Very Low alarm value using
keys in Scaled value
>
>
Set the Low alarm value using
keys in Scaled value
>
>
Set the High alarm value using
keys in Scaled value
>
>
Set the Very High alarm value using
keys in Scaled value
>
>
If PV is greater than then
V HIGH ALM Will ON
Very High
If PV is greater than and less
than Very High then HIGH ALM Will ON
High
If PV is less than and greater
than Very Low then LOW ALM Will ON
Low
If PV is less than then
V LOW ALM Will ON
Very Low
If PV is less than High and greater
than Low then PASS ALM Will ON
Initial Setting
Scaling Low Value
Scaling High value
Press
>