greenapple Biocheck-in User manual

Assembly Manual

2ASSEMBLY MANUAL 2020

3ASSEMBLY MANUAL 2020
INDEX
1.1 Safety Precautions
1.2 Warnings
1.3 Handling
1.4 Power and Plug
1.5 Usage Environment
1.6 Cleaning and maintenance
1.7 Biocheck-in
1.8 Components
1.9 Settings
1.10 APP
1.11 Bluetooth Pairing
1.
Introduction
PAGE. 04 2.
Prepare device for first use
3.
Additional information
2.1 Installation
2.2 Turn On
2.3 Plug in
2.4 Turn Off
2.5 Battery Charging process
3.1 Product specifications
3.2 Problems & Solutions
PAGE. 12
PAGE. 27

4
1.
ASSEMBLY MANUAL 2020
1.1 Safety Precautions
Read all instructions before operating
the device.
Keep this manual for future use.
The instructions for use must be
accessible to all users. All information
contained therein must be observed.
1.2 Warnings
Do not place the Biocheck-in in an
unstable location or with a very
uneven floor.
Do not expose the biocheck-in to rain
or to extreme weather conditions.
We recommend placing the device
away from direct sunlight.
Place the Biocheck-in on a levelled
surface, without irregularities under
the base.
Educate users and maintenance
about the dangers arising from
non-compliance with procedures.
In the event that the device is
used for purposes other than those
specified, it leaves to ensure its
correct operation!
Introduction
1.

5
1.
ASSEMBLY MANUAL 2020
1.3 Handling
Do not pull or push the Biocheck-in.
Do not attempt to open the door
without the key.
Do not touch the front panel with
sharp objects, you may scratch
and/or damage visibility.
Do not cause a strong impact or
pressure on the device body, you
may cause internal damages.
This object is not designed to be
used by children without supervision.
Avoid having direct contact with the
sensors. If there is a need to clean,
perform cleaning only at the alcohol
gel outlet.
1.4 Power and Plug
Unplug the device from the wall
outlet under the following conditions:
If the product will not be used for
a long period of time.
If the power cord, plug, socket
or battery is damaged.
If the product is damaged by a drop
or impact.
If the battery is placed with a power
source.
1.
Plug the device into an outlet under
the following conditions:
If the battery is discharged. Attention,
the power cord can be dangerous
in areas of high circulation.
1.5 Usage Environment
Operating Temperature: 5 ° C to 35 °
Operating Humidity: 20% to 80%,
non-condensing
Storage Temperature: -15 ° C to 45 °
Storage Humidity: 10% to 90%, non-
condensing
1.6 Cleaning and maintenance
Clean the Biocheck-in with a soft dry
cloth.
To avoid damages, do not apply
any type of force or wet the buttons
inside the compartment, where
the sensors are placed.
Do not use products with chemical
composition, it may damage the
surface finish.
Do not apply any force or pour any
liquid into the compartment,
it damages the electronics in
the device.

6
1.
ASSEMBLY MANUAL 2020
1
5
6
7
8
9
10
11
3
4
Card reader
Temperature sensor
Alcohol Gel outlet
Door lock
USB cable
Power bank
Gel deposit
Button ON / OFF
“Menu“ button
“Select“ button
1.7 Biocheck-in
2
Display

7
1.
ASSEMBLY MANUAL 2020
12
USB-C port
1.8 Components
The “Menu” and “Select” buttons
located inside the compartment allow
you to calibrate the Biocheck-in.
However, for simplified use,
www.biocheckin.pt
Button A “Menu” activates the
navigation options on the screen.
Button B ”Select” allows to select
the options.
l
0
A
B

8
1.
ASSEMBLY MANUAL 2020
1.9 Settings
Once the Button A “Menu “is selected,
the following options will appear on the
screen:
1. G, GEL. Dosage of alcohol gel.
Select from:
0.5 seconds (Aqueous gel)
1.0 seconds (Normal gel)
2.0 seconds (Viscous gel)
2. P, PUMP. It allows to prime
the pump.
Select from:
1, pump on.
0, pump off. Menu button (option
transition also turns off the bomb).
3. B, BRIGHTNESS.
Screen brightness. Allows you to
adjust the brightness between 10%
(minimum) and 100% (maximum)
brightness, in 10% iterations.
Note: Pressing the menu button
after the last option exits Menu
mode, and returns to normal
Biocheck-in operation.
Each option acts in real time, or
immediately demonstrates the effect:
The gel, dispenses a dose according
to the time selected on the screen.
The pump turns on and off.
The brightness is represented on
the screen, with the exception of 0%,
which takes effect once exiting
the menu.
1
2
3
G, Gel
P, Pump
B, Brightness

9
1.
ASSEMBLY MANUAL 2020
1.10 App
1. Download the Biocheck-in
from www.biocheckin.pt
2. Turn on your mobile device’s
Bluetooth. Get closer to Biocheck-in.
3. Pair your device with the
Biocheck-in.
4. On the home screen you will find the
change the device settings.
change and select different workflows
modes, the “Standdard” mode is
current usage mode.
7. The “Screen Brightness” button
brightness of the screen.
identifies the type of gel you place
in the tank.
csv file. with temperatures recordings,
battery levels and alcohol gel levels.
option to prime the pump and indicate
the replenishment of the tank (this
button have to be pressed each time
the tank is refilled)
D
A
E
F
G
H
I
B
C

10
1.
ASSEMBLY MANUAL 2020

11
1.
ASSEMBLY MANUAL 2020
1.11 Bluetooth Pairing
During pairing of the device with
the smartphone will appear on the
screen of the Biocheck-in a Bluetooth
icon. This icon indicates that at that
moment the application of Biocheck-in
becomes active in the device closest
to you.
Once the Bluetooth of the smartphone
to which it was paired is turned off
the Biocheck-in screen will display
the image above. The total reach of
Bluetooth in open spaces is 50 meters,
so the connection can be broken if
there are spaces with many obstacles
or by leaving this area limits.

12
2.
ASSEMBLY MANUAL 2020
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
4 x
4 x
12 x
Attention!
1. Before starting the assembly, make
sure you have the correct tools.
2. Two people are required for
transportation and assembly.
3. During assembly, place items
on a mat or protected surface,
never on the floor.
4. In case of doubt during assembly,
contact Greenapple.
2.1 Installation
Prepare device for first use

13
2.
ASSEMBLY MANUAL 2020
1. Place the stainless steel base
and foot in a horizontal plane.
2. Align the foot holes with the base.
3. Place the iron base aligned
with the same holes.

14
2.
ASSEMBLY MANUAL 2020
4. Tighten the washer screw, joining
the base to the foot.
5. Place the mdf base aligned with
the holes.
6. Screw and base.
2 x
8 x
1 x

15
2.
ASSEMBLY MANUAL 2020
7. Align the levelers with the holes.
8. Screw the levelers.
9. Check the piece stability.
4 x
1 x
8 x

16
2.
ASSEMBLY MANUAL 2020
10. Place the piece vertically.
11. Align the shore holes with the foot.
12. Tighten the washer screw,
joining the back to the foot.

17
2.
ASSEMBLY MANUAL 2020
13. Check the piece stability.
14. Place the hinges of the box in line
with the groove on the back.
15. Overlap the two elements and
perform with a pressure movement
on the tip of the hinge.

18
2.
ASSEMBLY MANUAL 2020
16. Stabilize the hinge alignment at
point A and apply pressure on point
B until it clicks into place.
17
the first use.
18. Place the power bank in the
compartment.
A B

19
2.
ASSEMBLY MANUAL 2020
19. Connect the USB cable in the
compartment to the respective power
bank socket.
20. Unscrew the tank cap.
21. Remove the tank from inside
the compartment. Do not fill the tank
while it is in the compartment. You may
damage the electronic components
if it leaks.

20
2.
ASSEMBLY MANUAL 2020
22
you will find the 1500ml marking that
indicates the maximum capacity
of the tank.
23. Place the tank inside the
compartment.
24. Screw on the cap correctly,
so that there is no leakage of gel.
Check if the alcohol tube is not
attached to the bottom or sides of the
tank. The tube must be suspended 5
mm from the bottom of the tank.
If the tube gets stuck, it will stick and
in certain situations does not let the
gel get into the tube.
Other manuals for Biocheck-in
1
Table of contents