43
65
DANGER OF
ELECTRICAL
SHOCK
WARNING
!
WELL VENTILATED PLACE
Please leave more than 10cm space between
freezer and wall. If there are no space, freezing
capacity can drop down.
If installation in a damp location is
unavoidable, also install an electrical
leakage circuit breaker. If no electrical
leakage circuit breaker is installed,
electrical shock could result.
PROHIBITED DISCONNECT
POWER CORD
PLUG FROM
WALL OUTLET
Never hang from the door or climb onto
the unit. The unit could tip over or fall and
cause material damage or injur y.
Disconnect the power cord plug from the
wall outlet before moving the unit and
make sure that the power cord is not
damaged during transport. A damaged
power cord could result in electrical shock
and/or fire
Grasp the handle when closing the door.
Holding at other positions could result in
pinched fingers and injury.
Do not push hand against or apply
excessive force to glass surfaces as the
glass could break and cause injur y.
When disconnecting the power cord plug
from the wall outlet, hold at the plug main
body close to the outlet. Pulling the cord
could cause wire breakage, possible
resulting in overheating and fire.
Make sure that the unit does not tip over or
fall when it is moved. A falling unit could
cause serious injur y.
Be sure attach and secure shelves
correctly. An improperly attached shelf
could fall down and cause injury.
DON'T PINCH
FINGERS
PROHIBITED
DON’T TOUCH
HOW TO USE
BEFORE USE
WAIT 5 MINUTES OR MORE BEFORE RE-STARTING
TEMPERATURE ADJUSTMENT
DRAIN TRAY
EFFICIENT USE
SHELF HEIGHT ADJUSTMENT
Remove shipping package, tape, etc and leave doors open ventilation for a while.
The unit is cleaned before shipment. However, clean the compartment interior once after delivery
Please insert power supply plug into the wall outlet, single-phale to cat voltage.
Allow the unit to operate for about 1 hour to cool the compartment before placing items in the freezer
Restarting the unit immediately after it has been turned off may cause fuses to blow and activate the
circuit-breaker, the compressor may be overloaded, and/or other damage may occur
The ambient of climatic class 0,1,2,3,4 is 32 Degree C.
For glassdoor freezer,the interior temp.will be kept at -22~-25 under +25 ambinet temp.If the
ambinet temp. is extremely high or the stuffing food inside is too much,that might cause the interior temp.
a little bit higher.So,it would be better turn the thermostat right so as to maintence the right temp. On the
opposite,if the ambinet temp. is very low or empty loaded,or in less food storage,the interior temp. might
be able to reach minus -30℃,and in return to cause the evaporator ice up;Thus,it would better to re-adjust
the digital thermostat.
℃ ℃
Defrosting is performed automatically every 6 hours(for ”FD”series only)and drain water is collected in the
drain tray.
Water is in the drain tray is evaporated automatically. In humidity, large amount of water in the drain tray,
so please throw away drain water once a day.
Please follow the below instruction, you could save energy.
To prevent cold air from escaping, open and close the door quickly and keep the door opened for as short
a time as possible keep the door open for more than 30'will result ice-cream melting.
Please install the unit in the place which is well-ventilated.
The shelf height can be adjusted(for ”FD”series only)
Arrange the shelves in accordance with the dimensions of the items to be placed in the freezer.
PLACING ITEMS IN THE FREEZER
This freezer employs a forced circulation of cold air system. If circulation of cold air is obstructed, the
items will not be adequately frozen. Pay attention to the following points:
Do not let items obstruct the cold air inlet and suction outlet.
Place items so that they do not protrude from the shelves. The gap between the shelves and the door is
used for circulation of cold air.
Place items evenly on all shelves.
Please do not display goods on the bottom. Please put goods on the shelf.
CLEANING
To prevent any electrical shock hazards or injur y by rotating circulation fan, always disconnect the power
cord plug from the wall outlet before cleaning.
WARNING
!
EXTERIOR AND FREEZER COMPARTMENT
Wipe with a soft, dry cloth. If ver y soiled, wipe with a cloth that has been moistened with a detergent. Then
wipe with a cloth that has been dipped in water.
WARNING: Do not splash water directly onto the freezer and do not wash with water. Short-circuit and
electrical shock could result.
WARNING
!
Clean the freezer regularly to keep it clean at times.
Never use polishing powder, soap powder,
benzene,Oil or hot water as these will damage the
painting and Plastic components
CHECKS
To ensure the safety, perform the following checks after cleaning.
Is the power cord plug firmly inserted into a dedicated wall outlet? Confirm that the plug is not abnormally
hot.
Check the power cord for cracks and damage. Should the slightest irregularity be obser ved, contact the
dealer from whom you purchased this unit or our customer’s service.
This marking indicates that this product should not be disposed with other household wastes throughout
the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal,
recycle it responsibly to promote the sustainable reuse of material resources. To return your used device,
please use the return and collection systems or contact the retailer where the product was purchased.
They can take this product for environmental safe recycling.
In case the unit shows operating problems,
check the following prior to calling the authorized service company:
SYMPTOMS
The unit is not
operating
POSSIBLE CAUSE SOLUTION
Not reaching
desired
temperature
Abnormal noises
Water on the floor
Faulty electrical contact
Poor electrical power
Thermostat setting "0"
Unit is exposed to direct sun light
Thermostat is not propertly adjusted
Clogger condenser
Blocked grills
Door not properly closed
Products poorly distributed
or excess product load
For Models with electronic
temperature controller,indicates E0 or E1
The unit is not properly level
Friction with other objects
Drain hose is outside of the drain pan
Verify electrical connections
Check the power connection and electrical outlet
Change the thermostat setting to a higher number
Relocate the unit to a shaded area
Adjust the thermostat setting to a higher number
Review Maintenance instrutions listed in the manual
Clean the grills of any debris collected
Check the leveling of the unit and door seal
Redistribute the product load according
Start instrutions
Unplug the unit from the outlet.If the error
continues,contact an authorized service
technician
Level the unit following the Installation instructions
Move the unit and avoid contact with other objects
Lovate the hose in the drain pan
WARRANTY & SERVICE
Warranty is valid for one year from the date of purchase.
The warranty covers defective parts and workmanship.The
following items are not covered under warranty:
1.Loss of products.
2.Damages caused by transportation.
3.Damages caused by modifications made by
unauthorized individuals.
4.Fluorescent lights,glass parts or plastic component
parts.
5.Worn out plugs or defective electrical components.
6.Maintenance of the unit.
Warranty is valid showing the purchase receipt.
We offer a professional service network which offers the
necessar y technical support for your unit.
See contact information in the back of the Manual.
Need manaul defrost ver y 1week to melt the ice on the shelves for a better freezing effect.(for”ZD”series only)
you need to collect the melting water by using a bucket
Do not throw items onto the shelves and do
not place items totaling more than 30kg on
each shelf. The shelf could fall down,
possibly cause injur y.
the maximum loading of each type of
shelf:30Kg