Specifications
rChannels:
C01 … C 99
Special channels S 01 … S41
rNorm:
PAL B/G; SECAM L; PAL-I/NIC-GB; SECAM D/K;
NTSC M; NIC (E-B-DK); NIC (S-N-SF)
rService hint for the specialist:
The mains cable is a plug-in type. For a replace-
ment, order it at our after-sales service under the
number 8290-991-316.
This unit conforms to VDE safety regulations and
directives of the Deutsche Bundespost (German
Federal Post Office; see certification mark on the
type sticker on the rear of the unit), as well as all
relevant ordinances governing X-ray emissions.
The picture tube, which emits X-rays, is sufficiently
shielded and therefore represents no danger. Acce-
lerating voltage is max. 34kV with a mean beam
current of 1.6mA.
Unauthorized tampering with the unit, in particular
making adjustments to the high voltage system, or
installing a different picture tube, can considerably
increase X-ray emissions. Units so altered no lon-
ger conform to applicable safety regulations and
may not be operated.
This TV set is prepared for satellite reception. As
extension kit, the module SER 150 is provided.
Ask your specialized dealer for further details.
This TV set is prepared for Dolby Sorround Prolo-
gic. As extension kit, the module DPL 1 is provi-
ded. Ask your specialized dealer for further
details.
rr Pin assignment of EURO-AV socket
If you want to connect other devices to your televi-
sion (for example, a computer or amplifier), your
dealer can provide you with a normed standard
connection by means of the following table:
Pin Signal
11 = Audio output, right
12 = Audio input, right
13 = Audio output, left
14 = Audio, earth
15 = Blue, earth
16 = Audio input left
17 = RGB blue input
18 = Switching voltage
19 = Green, earth
10 = Data line (MEGALOGIC)
11 = RGB green input
12 = –
13 = Red, earth
14 = Earth
15 = RGB red input
(S-Video = Chroma)
16 = RGB switching voltage
17 = Video, earth
18 = RGB switching voltage, earth
19 = Video output
20 = Video input
(S-Video = Luminanz)
21 Shielding/earth
rMains voltage:
220 – 240V, 50/60 Hz
(control range of the power supply unit 190 … 264V)
rPower consumption:
Set in Set in Sound output Sound output
operation standby Music power Sine power
approx. 180 W 6 W 80 W 2 x 10 + 20 W
Subject to alterations. E. and O.E.
Additional Information for Units sold in Great Britain
Units sold in GB are suitable for operation from a 240 V AC, 50 Hz mains supply.
In case this appliance is supplied with a Safety Standard Approved mains lead fit-
ted with a non-rewireable 13 Amp mains plug which, if unsuitable for your
socket, should be cut off and an appropriate plug fitted by a
qualified electrician. The fuse and fuse holder must be removed from the plug as
accidental insertion of the redundant plug into a 13 Amp socket is likely to cause
an electrical hazard.
Note: The severed plug must be destroyed to avoid a possible shock hazard
should it be inserted into a 13 Amp socket elsewhere.
If it is necessary to change the fuse in the non-rewireable plug, the correct type
and rating (5 Amp ASTA or BSI approved BS 1362) must be used and the fuse
cover must be refitted. If the fuse cover is lost or damaged the lead and plug must
not be used until a replacement is obtained. Replacement fuse covers should be
obtained from your dealer.
If a non-rewireable plug or a rewireable 13 Amp (BS 1363) plug is used, it must
be fitted with a 5 Amp ASTA or BSI approved BS 1362 fuse. If any othe type of
plug is used it must be protected by a 5 Amp fuse either in the plug or at the dis-
tribution board.
Important:
The wires in the mains lead are coloured in accordance with the follow-ing code:
BLUE – NEUTRAL
BROWN – LIVE
As the colours of the wires in the mains lead of your appliance may not corre-
spond with the coloured marking identifying the terminals in your plug, proceed
as follows:
Connect the BLUE coloured wire to plug terminal marked with the letter "N" or
coloured black.
Connect the BROWN coloured wire to the plug terminal marked with a letter "L" or
coloured red.
In no circumstance must any of the wires be connected to the terminal marked
with a letter "E", earth symbol , coloured green or green and yellow.
Replacement mains lead can be obtained from your dealer.