PATROL – 801PET
PROFESSIONAL COMBINED
DIGITAL PIR & GLASS
BREAK DETECTOR
WITH PET IMMUNITY
INSTALLATION
INSTRUCTIONS
OC03
www.gsncompany.com
FEATURES.
•Immune to pets up to 30kg
•Digital mathematical algorithm
of signal processing
•High light immunity – no less
than 10000 Lux
•High RFI & EMI immunity
•Two optoelectronic switch relays
for glass break and PIR detectors
•Test mode for two acoustic channels
•Hermetically insulated PYRO sensor
•Automatic temperature compensation
•Pulse counter.
DESCRIPTION.
The PATROL-801PET is immune
to pets of up to 30kg and 1m height.
The PATROL-801PET is a combination
of PIR and acoustic glass break
detectors.
The PIR detector analyzes the
environment and detects the person's
motion crossing the infrared beam.
The acoustic glass break detector
identifies the sounds of glass impact
and breakage.
Due to unique program for processing
incoming signals from PIR and
GLASS BREAK detectors the
PATROL-801PET enables an
exceptionally reliable detection and
stable "false alarms free" operation in
extremely harsh environments.
ALGORITHM.
Unique algorithm is based on recognition
of sequence of low-frequency and
high-frequency signals of framed pane
glass breakage. Low-frequency signal
is emitted upon the impact of glass.
High-frequency signal occurs upon the
glass breakage.
HIGH FREQUENCY LOW FREQUENCY
SIGNAL SIGNAL
For creating an alarm, both a
low-frequency sound of the glass
impact and a high-frequency glass
breakage sound must be registered
within a predetermined time frame.
Since both detector channels must
register the actual glass breakage,
false alarms are practically excluded.
The program of microcontroller,
based on the mathematical algorithm,
analyzes signals and detects only the
actual breakage of all standard framed
glass types.
PROTECTED GLASS TYPES.
Glass
type Min.
Thickness Max.
Thickness
Plate 2 mm 10 mm
Tempered 3 mm 8.4 mm
Patterned 3 mm 10 mm
Laminated ¹ 3.2 mm 14.3 mm
Wired 5 mm 6.4 mm
Coated ²
(Triplex) 2.5 mm 8.4 mm
Sealed
Insulating ¹ 3.2 mm 6.4 mm
¹ Laminated and sealed insulating
glass types are protected only
if both glass plates are broken.
² For glass coated with plastic film
on the inner surface, effective range
is reduced to 6m.
SELECTING MOUNTING
LOCATION.
Choose a location most likely to
intercept an intruder.
The recommended installation height
to gain maximum protection zone
is 2.1 - 2.3 meters.
For protecting several windows mount
the detector at optimal distance from
them. If heavy blinds of curtains cover
the glass, locate the detector so the
blinds will not block the sound.
void the following locations:
- Near sources of loud noises or
vibrations (heating/air conditioning
units, bells, fans, compressors, etc.)
- On the same wall as protected glass.
PET IMMUNITY SETTING.
Set the switch S2 according to
the animal weight.
10KG
20KG
30KG
S2
PULSE COUNTER.
Set the jumper W5 to the "1P" position
for premises with stable environment.
Set the jumper W5 to the "2P" position
for locations with harsh environment.
1P
W5
2P