ACS-102
WIRELESS DUAL-CHANNEL
ALARM SYSTEM SET
INSTALLATION
INSTRUCTIONS AND
TECHNICAL SPECIFICATIONS
OC03
www.gsncompany.com
INTRODUCTION.
ACS-102 is a wireless dual-channel
multi purpose alarm system
set designed for use as a
PANIC BUTTON IN SECURITY
SYSTEMS and for remote
controlling of:
•ELECTRICAL GATES
•SLIDING DOORS
•ELECTROMAGNETIC LOCKS
•AUTOMATIC BARRIERS
•ELECTRICAL CURTAINS
•LIGHTING APPLIANCES, ETC.
ACS-102 RECEIVER FEATURES.
- Two independent channels
- Four operating modes for each
channel:
1. PANIC BUTTON MODE
(SECURITY)
2. SWITCHING MODE (ON/OFF)
3. HOLD MODE (CONTINUOUS)
4. PULSE MODE. 1 SECOND
- Maximum quantity of remote
controls programming the
receiver:……...................680(pcs)
- Easy receiver programming by
additional remote controls
- Unauthorized access protection
- Last event memory:……...30min
1 2 3
1. «PANIC BUTTON MODE».
This mode is used in security
systems. The alarm occurs by
pressing any of the remote control
buttons or by unauthorized receiver
opening.
«PANIC BUTTON MODE»
FEATURES:
A. POWER LOSS PROTECTION.
The relay operates in active mode.
In case of power loss or intentional
disconnection the relay opens its
contacts.
B. LAST EVENT MEMORY.
Press the remote control button -
receiver’s LED starts blinking – the
memory timer is on. Timer’s
operating period is 30 minutes.
After the period of 30 minutes the
memory is automatically erased.
NOTE!
The receiver memory saves only the
last event, erasing the previous one.
C. THE UNAUTHORIZED
OPENING PROTECTION.
In the «PANIC BUTTON MODE»
a tamper switch provides an
unauthorized opening protection
of the receiver.
ATTENTION!
In the «PANIC BUTTON MODE»
the receiver does not operate if the
cover is removed.
4 5 6
2. «SWITCHING MODE» (ON/OFF).
This mode is for use in control
systems of various devices.
Each pressing the remote control
button corresponds to one of the
relay positions (ON/OFF).
3. «HOLD MODE» (CONTINUOUS).
The receiver relay activates for the
period of continuous pressing any
of the remote control buttons.
4. «PULSE MODE» (PULSE).
The pressing one of the remote
control buttons causes the relay
to activate for 1 second.
ACS-102 RECEIVER MEMORY
CAPACITY.
The receiver ACS-102 is capable of
memorizing up to 680 different codes
and thus of operating with 680 remote
controls.
THE REMOTE CONTROL.
The wireless remote control has
two buttons corresponding to two
channels of the receiver.
Both buttons of the remote control
can be used to program and operate
the receiver.
LED INDICATIONS.
1. LED is on – the receiver is
operating.
2. LED blinks – the memory timer is
on (in the Panic Button Mode).
OPERATING MODE SELECTION.
1. Disconnect power.
2. Remove the cover.
3. Place jumpers at the desired
setting (see Figure 1).
4. Restore power.
5. Program the receiver by the
remote control.
6. Replace the cover.
7 8 9
THE RECEIVER CONNECTION.
Run the cable through the cable entry
hole and connect the wires
in accordance to the following
instructions:
TERMINAL 1,2 - marked -12V+.
The receiver ACS-102 operates on input
power of 12-16VDC.
TERMINALS 3, 4, 5, 6, 7, 8 – relay
output for two channels of the
receiver (RELAY-1), (RELAY-2).
1 2 3 4 5
6 7 8
12V+
-NC C NO
RELAY 1
NC C NO
RELAY 2
SETTING THE
OPERATING MODES.
For programming the receiver by
additional remote controls and
operating modes settings refer to
«Figure-1».
Jumper (LRN) – for programming the
receiver by remote controls.
Jumpers (SEC-1) and (TGL-1) – for
operating mode settings of the first
channel.
Jumpers (SEC-2) and (TGL-2) – for
operating mode settings of the
second channel.
ATTENTION!
The manufacturer guarantees flawless
operation of the receiver if the change
of operating modes is carried out when
the power supply is disconnected.
PROGRAMMING
MODE
TGL-2 SEC-2 TGL-1 SEC-1 LRN
PANIC BUTTON MODE
(SECURITY)
TGL-2 SEC-2 TGL-1 SEC-1 LRN
SWITCHING MODE
(ON/OFF)
TGL-2 SEC-2 TGL-1 SEC-1 LRN
HOLD MODE
(CONTINUOUS)
TGL-2 SEC-2 TGL-1 SEC-1 LRN
PULSE MODE
1 SECOND (PULSE)
TGL-2 SEC-2 TGL-1 SEC-1 LRN
9Jumpers position according to
operating modes of the receiver for
two channels.
«FIGURE-1»
10 11 12
MEMORY CLEARING.
1. Disconnect power.
2. Remove jumper “LRN”.
3. Restore power – LED starts
slowly blinking for 10 seconds, then
the cycle frequency of LED operation
changes. All pre-programmed codes
will be erased.
4. Replace jumper “LRN”.
5. Start new programming of the
receiver.
PROGRAMMING THE RECEIVER.
1. Remove jumper “LRN” –
LED will be off.
2. Press any of the remote control
buttons – the receiver’s LED will
flash once indicating successful
code memorizing – the receiver is
programmed by the remote control.
3. Replace jumper “LRN”.
4. To test the programmed code,
press continuously the tamper button.
In 3 seconds press the remote control
button. The simultaneous relay and
LED activation indicates successful
code memorizing.
5. To program the receiver by
additional remote controls, repeat
the mentioned above operations
(Items 1-4).
IMPORTANT!
The receiver programming in the
«PANIC BUTTON MODE» causes
immediate activation of the event
memory for last 30 minutes.
LED INDICATION DURING
RECEIVER PROGRAMMING.
1. LED blinks intermittent – there
is no code saved in the receiver
memory.
2. LED is off – the receiver is ready
for programming.
3. LED flashed ones – the remote
control code is saved in the receiver
memory.
13 14 15
TECHNICAL SPECIFICATION.
Power Input:......................12-16VDC
Current Consumption:
Stand-by mode:…………46mA - 12V
Active mode:…………….27mA - 12V
Receiving Range in
Open Space:…………….200 - 250m
Operating Frequency:.....433.92MHz
Effective Radiated Power
of Remote Controls:……..… ≤10mW
Memory Capacity:………...680codes
Alarm Period in
Panic Button Mode :……………3sec
Warm up
Period:……………………........0.5sec
Opening Protection:...Tamper Switch
Dry Contact Relay:……………………
…………………..….…..DC30V, 1.0A
……………………….....DC60V, 0.3A
…………………………AC125V, 0.5A
Operating Temp:……….-20ºC +50ºC
Storage Temp:………....-40ºC +80ºC
Dimensions:.85mm x 40mm x 20mm
Weight:…………………………...95gr.
P/N: USM0E102 REV.A PRINTED IN ISRAEL
WARRANTY.
GSN Electronic Company Ltd.
warrants the product to be free from
defects in materials and workmanship
under condition of observance
of service regulations and to be
repaired or replaced under absence
of mechanical damages for a limited
period of five years from the date
of sale.
7 ATARA ST.
NAZARETH ILLIT 17802
P.O.BOX 17719
ISRAEL
TEL: 972 4 6467152
FAX: 972 4 6562414
WWW.GSNCOMPANY.COM
16 17 18

Popular Security System manuals by other brands

First Alert CO615 user manual

First Alert

First Alert CO615 user manual

ZKTeco FR1200 user manual

ZKTeco

ZKTeco FR1200 user manual

Epicalert Apex EPIC-AP130 Installer manual

Epicalert

Epicalert Apex EPIC-AP130 Installer manual

Honeywell Home PROA7PLUS Series Installation and setup guide

Honeywell Home

Honeywell Home PROA7PLUS Series Installation and setup guide

LDA Audio Tech NEO Series Support Handbook

LDA Audio Tech

LDA Audio Tech NEO Series Support Handbook

Panasonic EBL128 operating instructions

Panasonic

Panasonic EBL128 operating instructions

DAITEM ALARM SYSTEM AND DIALLER user guide

DAITEM

DAITEM ALARM SYSTEM AND DIALLER user guide

Pump Alarm Cellular Alarm Quick start installation guide

Pump Alarm

Pump Alarm Cellular Alarm Quick start installation guide

Honeywell X-618 installation manual

Honeywell

Honeywell X-618 installation manual

GE Simon XT V2 user manual

GE

GE Simon XT V2 user manual

SILENTRON Sil Bus Instructions and warnings for installation and use

SILENTRON

SILENTRON Sil Bus Instructions and warnings for installation and use

Emerson FA-700 Installation and operation manual

Emerson

Emerson FA-700 Installation and operation manual

BIRD 6150-ALM-03 Operation manual

BIRD

BIRD 6150-ALM-03 Operation manual

Wirepath Surveillance Control4 Installation and setup

Wirepath Surveillance

Wirepath Surveillance Control4 Installation and setup

System Sensor SSM24-6 Installation and maintenance  instruction

System Sensor

System Sensor SSM24-6 Installation and maintenance instruction

OPTICOM KDE-8 datasheet

OPTICOM

OPTICOM KDE-8 datasheet

Kompernass TA 120 A2 operating instructions

Kompernass

Kompernass TA 120 A2 operating instructions

Barracuda PUMPS 691-3703 owner's manual

Barracuda PUMPS

Barracuda PUMPS 691-3703 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.