manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GSSI
  6. •
  7. Measuring Instrument
  8. •
  9. GSSI Flex NX User manual

GSSI Flex NX User manual

Flex NX Support
SIMPLE. FLEXIBLE. TRUSTED.
Quick Start Guide
MN73-190 Rev A
Flex NX Support
SIMPLE. FLEXIBLE. TRUSTED.
Quick Start Guide
MN73-190 Rev A
®
®
Have Questions?
Our promise to you is to provide comprehensive training,
unrivaled customer support and world class expertise. That’s why
your Flex NX comes with our industry-leading two-year warranty,
complimentary training, and technical support access. For more
information, visit us at www.geophysical.com.
Our team of dedicated technical trainers is ready
to work with users of all experience levels. GSSI
Academy classes are oered on a revolving
annual schedule. Check out the GSSI Academy
oerings at www.geophysical.com/gssi-academy.
We’re Committed to Your Success
We’ve Got Your Back
Have Questions?
Our promise to you is to provide comprehensive training,
unrivaled customer support and world class expertise. That’s why
your Flex NX comes with our industry-leading two-year warranty,
complimentary training, and technical support access. For more
information, visit us at www.geophysical.com.
Our team of dedicated technical trainers is ready
to work with users of all experience levels. GSSI
Academy classes are oered on a revolving
annual schedule. Check out the GSSI Academy
oerings at www.geophysical.com/gssi-academy.
We’re Committed to Your Success
We’ve Got Your Back
What’s Included
Flex NX Controller
FGFLEX NX
Transit Case
F-73-176
Lithium-Ion Battery (2X)
FGNX-BAT-3 CELL
2-Bay Charger
FGMODBC-NX
Extra RAM® Mount
RAM-238U
Quick Start Guide
MN73-190
Wrist Lanyard
F-73-159
What’s Included
Flex NX Controller
FGFLEX NX
Transit Case
F-73-176
Lithium-Ion Battery (2X)
FGNX-BAT-3 CELL
2-Bay Charger
FGMODBC-NX
Extra RAM® Mount
RAM-238U
Quick Start Guide
MN73-190
Wrist Lanyard
F-73-159
Optional NX Accessories
Telescoping Pole with RAM Grip - 0.5m-1.2m (1.7ft-4.0ft)
For use with Flex NX and NX25
FGNX-POLE
NX25 Wireless Satellite Antenna
FGNX25
Optional NX Accessories
Telescoping Pole with RAM Grip - 0.5m-1.2m (1.7ft-4.0ft)
For use with Flex NX and NX25
FGNX-POLE
NX25 Wireless Satellite Antenna
FGNX25
NX25 Lithium-Ion Battery (2X)
FGNX-BAT-2 CELL
NX25 Lithium-Ion Battery (2X)
FGNX-BAT-2 CELL
Flex NX Physical Features
Flex Vision
Positioning System
External USB Port
User Programmable Buttons
Power On/O
User Replaceable Wheels
with Individual Encoders
Removable High-Capacity
Lithium-Ion Battery
Universal RAM® (Size C)
Handle Mount
Flex NX Physical Features
Flex Vision
Positioning System
External USB Port
User Programmable Buttons
Power On/O
User Replaceable Wheels
with Individual Encoders
Removable High-Capacity
Lithium-Ion Battery
Universal RAM® (Size C)
Handle Mount
Flex NX Handle Adjustment
Your Flex NX features a fully adjustable and
removable handle. To adjust, simply loosen the
knob, reorient the handle, and tighten.
To remove the handle, fully loosen the knob.
360 degree range of
horizontal motion.
Vertical range of movement
is limited to prevent display
damage.
Flex NX Handle Adjustment
Your Flex NX features a fully adjustable and
removable handle. To adjust, simply loosen the
knob, reorient the handle, and tighten.
To remove the handle, fully loosen the knob.
360 degree range of
horizontal motion.
Vertical range of movement
is limited to prevent display
damage.
Flex NX and NX25 Attachments Flex NX and NX25 Attachments
Attaching the Telescoping Pole
Accessory (sold separately) to
Flex NX.
The NX25 Pole Mount Adapter and
Survey Wheel attachment locations are
interchangeable. Note: They can only
attach in orientations shown.
Engage the locking pin and insert the
right side, with the locking pin to the
left. Next, insert the locking pin side and
disengage the locking pin. To remove,
reverse the process.
The NX25 Pole Mount Adapter and
Survey Wheel attachment locations are
interchangeable. Note: They can only
attach in orientations shown.
Engage the locking pin and insert the
right side, with the locking pin to the
left. Next, insert the locking pin side and
disengage the locking pin. To remove,
reverse the process.
Attaching the Telescoping Pole
Accessory (sold separately) to NX25.
Attaching the Telescoping Pole
Accessory (sold separately) to NX25.
Attaching the Telescoping Pole
Accessory (sold separately) to
Flex NX.
Powering Flex NX
To insert the battery,
slide battery door latch
to left, and open the door.
Insert the battery in the
orientation shown.
Note: Battery contacts toward
Flex NX and facing upward.
Press both buttons to
Power On. Hold both
buttons to Power O.
Powering Flex NX
Note: Battery contacts toward
Flex NX and facing upward.
Press both buttons to
Power On. Hold both
buttons to Power O.
To insert the battery,
slide battery door latch
to left, and open the door.
Insert the battery in the
orientation shown.
Close the battery door and
ensure that the door latch is
fully engaged by pushing it
to the right.
Close the battery door and
ensure that the door latch is
fully engaged by pushing it
to the right.
Powering NX Accessory Antennas
Slide battery latch lock forward.
Use battery to push up on the
battery latch to insert.
Note: Battery can only be inserted
with battery contacts toward
NX25 and facing downward.
One-handed battery ejection:
Use thumb to press on battery
and index finger to slide the
battery latch lock. Pinching
fingers together will eject the
battery.
Press both buttons to
Power On. Hold both
buttons to Power O.
Powering NX Accessory Antennas
Slide battery latch lock forward.
Use battery to push up on the
battery latch to insert.
Note: Battery can only be inserted
with battery contacts toward
NX25 and facing downward.
One-handed battery ejection:
Use thumb to press on battery
and index finger to slide the
battery latch lock. Pinching
fingers together will eject the
battery.
Press both buttons to
Power On. Hold both
buttons to Power O.
Antenna / Laser Positions
Flex NX incorporates two individual GPR antennas:
AStandard Orientation antenna (in front)
and a Cross Polarized antenna (in back).
Red Lasers at center
points of Standard
Antenna
Green Lasers at center
points of Cross Polarized
Antenna
Each antenna has
three centered line
lasers for highly
accurate markouts.
The center of each
antenna is marked
with a colored
crosshair.
Each antenna has
three centered line
lasers for highly
accurate markouts.
The center of each
antenna is marked
with a colored
crosshair.
Scanning with both
antennas produces
a more detailed and
informative view of
concrete targets,
especially for
complex jobs.
Scanning with both
antennas produces
a more detailed and
informative view of
concrete targets,
especially for
complex jobs.
Forward
Direction
Forward
Direction
Antenna / Laser Positions
Flex NX incorporates two individual GPR antennas:
AStandard Orientation antenna (in front)
and a Cross Polarized antenna (in back).
Red Lasers at center
points of Standard
Antenna
Green Lasers at center
points of Cross Polarized
Antenna
NX Accessory Pairing
Flex NX and its accessory antennas (sold separately) connect
wirelessly using Tap-to-Connect Near Field Communication
(NFC) sensors.
Power on Flex NX and then the accessory antenna. Wait for the accessory
antenna’s indicator light to flash blue, and then bring the NFC labels together
to automatically pair. In future sessions, simply power on the accessory
antenna; NFC pairing will not be required.
NX Accessory Pairing
Flex NX and its accessory antennas (sold separately) connect
wirelessly using Tap-to-Connect Near Field Communication
(NFC) sensors.
Power on Flex NX and then the accessory antenna. Wait for the accessory
antenna’s indicator light to flash blue, and then bring the NFC labels together
to automatically pair. In future sessions, simply power on the accessory
antenna; NFC pairing will not be required.
Flex NX DashboardFlex NX Dashboard
After powering on, Flex NX will start every new session at the Main
Dashboard. From here, you can tap the icon to access system settings.
Tap the icon to quickly start a scan.
After powering on, Flex NX will start every new session at the Main
Dashboard. From here, you can tap the icon to access system settings.
Tap the icon to quickly start a scan.
Flex NX Settings Flex NX Settings
The Settings Menu is the control panel for customizing your Flex NX
experience. We recommend enabling the lasers to get started. WiFi
is enabled by default. When features are active you’ll see them represented
as colored icons on the Flex NX graphic. Tap the Xto return to the Main
Dashboard.
The Settings Menu is the control panel for customizing your Flex NX
experience. We recommend enabling the lasers to get started. WiFi
is enabled by default. When features are active you’ll see them represented
as colored icons on the Flex NX graphic. Tap the Xto return to the Main
Dashboard.
Select Concrete Type
When starting a new scan you’ll be prompted to select the appropriate
Concrete Type based the state of concrete cure. This menu only appears once
during each session. Note: This setting will greatly impact depth readings.
While collecting or viewing data, use the Depth Settings Menu to further refine
the depth scale accuracy.
Select Concrete Type
When starting a new scan you’ll be prompted to select the appropriate
Concrete Type based the state of concrete cure. This menu only appears once
during each session. Note: This setting will greatly impact depth readings.
While collecting or viewing data, use the Depth Settings Menu to further refine
the depth scale accuracy.
Data Collection Screen Data Collection Screen
A blank data collection screen will appear. Tap the icon to initiate a scan, and
then move Flex NX forward to begin collecting data. Data will populate from left
to right. Move Flex NX in reverse to view backup cursors that align with the red
and green side lasers.
View the Top Navigation Bar
Access and adjust the Gain, Display and Depth settings.
Stop data collection
A blank data collection screen will appear. Tap the icon to initiate a scan, and
then move Flex NX forward to begin collecting data. Data will populate from left
to right. Move Flex NX in reverse to view backup cursors that align with the red
and green side lasers.
View the Top Navigation Bar
Access and adjust the Gain, Display and Depth settings.
Stop data collection
Collecting GPR Data
The GPR data will reveal two distinct categories of reflections: targets, and
layers. Targets, such as rebar and conduit, are discrete objects below the
surface and are represented by hyperbolas (orange boxes). Layers are
continuous features, like the slab/grade contact (blue box).
The GPR data will reveal two distinct categories of reflections: targets, and
layers. Targets, such as rebar and conduit, are discrete objects below the
surface and are represented by hyperbolas (orange boxes). Layers are
continuous features, like the slab/grade contact (blue box).
Collecting GPR Data
Closely-spaced targets,
like wire mesh, produce
abundant hyperbolas
that overlap on the sides.
Closely-spaced targets,
like wire mesh, produce
abundant hyperbolas
that overlap on the sides.
Rebar and other metallic
targets produce bright
hyperbolas. Rebar
targets are often spaced
wider than wire mesh
targets.
Rebar and other metallic
targets produce bright
hyperbolas. Rebar
targets are often spaced
wider than wire mesh
targets.
Layers do not produce
hyperbolas. They appear
as continuous features
that often vary in bright-
ness and depth.
Layers do not produce
hyperbolas. They appear
as continuous features
that often vary in bright-
ness and depth.
Improving Data Visualization
While collecting data you can tap the icon on the depth scale. This will
open a window with three nested menus: Gain, Display, and Depth. For now,
click the Gain icon in the lower left. Here you can use the slider to adjust
the overall contrast of the data, or select one of three general depth levels
(shallow, medium, deep) to selectively adjust contrast.
Improving Data Visualization
While collecting data you can tap the icon on the depth scale. This will
open a window with three nested menus: Gain, Display, and Depth. For now,
click the Gain icon in the lower left. Here you can use the slider to adjust
the overall contrast of the data, or select one of three general depth levels
(shallow, medium, deep) to selectively adjust contrast.
Adjusting Display Options
Tap the icon at the bottom of the panel to adjust Display settings. Here
you can quickly change your data display from split screen with both
antennas to full screen options for the standard (front) and cross polarized
(rear) antennas. You can also adjust color tables, toggle the O-Scope, or
enable Focus Mode.
Adjusting Display Options
Tap the icon at the bottom of the panel to adjust Display settings. Here
you can quickly change your data display from split screen with both
antennas to full screen options for the standard (front) and cross polarized
(rear) antennas. You can also adjust color tables, toggle the O-Scope, or
enable Focus Mode.
Warranty Information
Limited Warranty, Limitations of Liability and Restrictions
Geophysical Survey Systems, Inc. hereinafter referred to as GSSI, warrants that
for a period of 24 months from the delivery date to the original purchaser this
product will be free from defects in materials and workmanship. EXCEPT FOR THE
FOREGOING LIMITED WARRANTY, GSSI DISCLAIMS ALL WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. GSSI’s obligation is limited to repairing or replacing
parts or equipment which are returned to GSSI, transportation and insurance prepaid,
without alteration or further damage, and which in GSSI’s judgment, were defective or
became defective during normal use. GSSI ASSUMES NO LIABILITY FOR ANY DIRECT,
INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR INJURIES
CAUSED BY PROPER OR IMPROPER OPERATION OF ITS EQUIPMENT, WHETHER
OR NOT DEFECTIVE. Before returning any equipment to GSSI, a Return Material
Authorization (RMA) number must be obtained. Please call the GSSI Customer Service
Manager who will assign an RMA number. Be sure to have the serial number of the unit
available.
Regulatory Information: https://www.geophysical.com/regulatoryinformation
Copyright © 2023 Geophysical Survey Systems, Inc.
All rights reserved including the right of reproduction in whole or in part in any form.
Published by Geophysical Survey Systems, Inc., 40 Simon Street Nashua,
New Hampshire 03060-3075 USA. Printed in the United States. Flex NX, Nexus,
and GSSI Fusion are registered trademarks of Geophysical Survey Systems, Inc.
Warranty Information
Limited Warranty, Limitations of Liability and Restrictions
Geophysical Survey Systems, Inc. hereinafter referred to as GSSI, warrants that
for a period of 24 months from the delivery date to the original purchaser this
product will be free from defects in materials and workmanship. EXCEPT FOR THE
FOREGOING LIMITED WARRANTY, GSSI DISCLAIMS ALL WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. GSSI’s obligation is limited to repairing or replacing
parts or equipment which are returned to GSSI, transportation and insurance prepaid,
without alteration or further damage, and which in GSSI’s judgment, were defective or
became defective during normal use. GSSI ASSUMES NO LIABILITY FOR ANY DIRECT,
INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR INJURIES
CAUSED BY PROPER OR IMPROPER OPERATION OF ITS EQUIPMENT, WHETHER
OR NOT DEFECTIVE. Before returning any equipment to GSSI, a Return Material
Authorization (RMA) number must be obtained. Please call the GSSI Customer Service
Manager who will assign an RMA number. Be sure to have the serial number of the unit
available.
Regulatory Information: https://www.geophysical.com/regulatoryinformation
Copyright © 2023 Geophysical Survey Systems, Inc.
All rights reserved including the right of reproduction in whole or in part in any form.
Published by Geophysical Survey Systems, Inc., 40 Simon Street Nashua,
New Hampshire 03060-3075 USA. Printed in the United States. Flex NX, Nexus,
and GSSI Fusion are registered trademarks of Geophysical Survey Systems, Inc.
Geophysical Survey Systems, Inc
40 Simon Street
Nashua, NH 03060-3075 USA
Patent www.geophysical.com/patents
Flex NX Support
Geophysical Survey Systems, Inc
40 Simon Street
Nashua, NH 03060-3075 USA
Patent www.geophysical.com/patents
Flex NX Support

Other manuals for Flex NX

1

Other GSSI Measuring Instrument manuals

GSSI StructureScan Mini XT User manual

GSSI

GSSI StructureScan Mini XT User manual

GSSI Flex NX User manual

GSSI

GSSI Flex NX User manual

Popular Measuring Instrument manuals by other brands

janitza UMG507 Installation and Initial Startup

janitza

janitza UMG507 Installation and Initial Startup

Fluke 945 user manual

Fluke

Fluke 945 user manual

Beta 1662DGT Instructions for use

Beta

Beta 1662DGT Instructions for use

janitza UMG 104 Operating manual and technical data

janitza

janitza UMG 104 Operating manual and technical data

SEFRAM BK Precision DAS30 user manual

SEFRAM

SEFRAM BK Precision DAS30 user manual

Bms Bulut Makina TKM-459 Operational manual

Bms Bulut Makina

Bms Bulut Makina TKM-459 Operational manual

Shodex CLNpak EV-2000 Operation manual

Shodex

Shodex CLNpak EV-2000 Operation manual

ABB VSN730 product manual

ABB

ABB VSN730 product manual

Keysight Technologies N774 C Series user guide

Keysight Technologies

Keysight Technologies N774 C Series user guide

Miura CMU-324GE Operation manual

Miura

Miura CMU-324GE Operation manual

Dresser 10C25 K Series Installation, operation and maintenance manual

Dresser

Dresser 10C25 K Series Installation, operation and maintenance manual

Keysight B2900A Demo guide

Keysight

Keysight B2900A Demo guide

dacell PDN-10 user manual

dacell

dacell PDN-10 user manual

ABB AX410 user guide

ABB

ABB AX410 user guide

Direct Supply Attendant owner's manual

Direct Supply

Direct Supply Attendant owner's manual

Fluidwell E126-P-EL manual

Fluidwell

Fluidwell E126-P-EL manual

HEDÜ D104 quick start guide

HEDÜ

HEDÜ D104 quick start guide

Bosch GLM Professional Original instructions

Bosch

Bosch GLM Professional Original instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.