Habitat HTE-01 Operating instructions

Programming Guide
Smarter Control Solutions.

About This Manual
This manual uses special attention icons to alert the reader of important
safety concerns, information important to reliable operation of the controls
or helpful installation/setup information.
Safety: Indicates a condition which may cause severe personal
injury, death or major property damage.
Important Information: Indicates information which requires
special attention for correct operation of the control.
Your Benet: Indicates helpful installation or setup information.
For installation and instructions, refer to the
Installation & Pairing Manual.
For operating instructions, refer to the
Operation Manual.
Documentation
i

ii
Habitat Technologies
330 East 38th Street, Suite 530
New York, NY 10016
Customer Service
Toll Free: 1-800-717-1682
Web Site: www.habitattechnologies.com
Manual Table of Contents
About This Manual
HTE-01 Thermostat - Home Screen Display
HTE-01 Thermostat - Controls
HTM-01 Base Module - LED Status Indication
HTE-01 Thermostat - Parameter Setup
- Identify HTM-01 Base Module(s)
- Pairing Additional HTM-01 Base Module(s)
- Daylight Savings Time, Date & Time Settings
- Emergency Heat Setting
- HTE-01 Thermostat Schedule Setup
HTE-01 Thermostat Administrative Parameters
- Unpair Modules
- Enable Auto Changeover, Button Press Sound, Enable Compressor
O Delay
- Compressor O Delay Time, Heat/Cool Dierential, Span
- Temperature Oset, Freeze Protection
- Maximum/Minimum Set Point, Lock Set Point
- Base Module Alarm Check Period, Factory Reset
Designed and Engineered in New York
U.S. registered Trademark, Patents pending
Copyright 2020, All Rights Reserved.
Thermostat
HTE-01
Module
HTM-01
i
1-2
3-4
5
6
7-8
9-10
11
12
12-14
15
15
16
17
18
19
20

1
Home Screen Display
1
2
3
4
5
6
7
9
10
11
12
13
14
8

2
1
Pairing status indicator:
Connected
Not connected
8Time display1
2
WIFI status indicator (only shown
when WIFI module is used)
Connected
Not Connected
9
Override status indicator1:
Override – Temporary Override
Perm. Override – Permanent
Override
3
Thermostat Battery power indicator
status, only shown when on battery
power used.
Full Half Low Replace
10
Schedule running indicator:
Schedule – Schedule running1
(Blank) No Schedule
4System type 11 Set point
5Room temperature 12 Celsius or Fahrenheit units
6Mode status 13 Emergency heat indication
7Additional system type text 14 Fan speed indication
1 - Schedule must be activated for the time & schedule status to be displayed.
See the Habitat programming guide for information on setting up a schedule.

3
HTE-01 Thermostat Controls
1
2
3
4
5
Front
View
Bottom
Side View

4
LCD Display – See preceding pages for detailed descriptions of the
display icons.
– Increase or Decrease the target temperature set point.
Changing the target set point:
• Press the or button while in Auto, Heat or Cool Modes.
• If a schedule is programmed, “Override” is displayed below the
time indicating that the current target setpoint will be maintained
until the:
- Next schedule period
- Set point is changed to the scheduled value
- Mode button is held for 3 seconds, displaying “Schedule”,
“Perm. Override”
- To change the temperature units between °F and °C, simultaneously
press the and buttons briey.
Mode – Cycle through Operation modes:
Fan – Cycle through desired Fan Speeds.
Manual Reset – Reboots the thermostat system only.
To save energy, the display will turn o after a period of inactivity.
Before making changes, press any button to activate the display,
illuminating the screen.
5
1
2
3
4

5
The following table shows the base module state corresponding to the
LED Status Indication.
HTM-01 Base Module LED Status Indication
LED Status Indication State Description
Flashing
Green Pairing Base module is seeking to pair with
the thermostat.
Green Paired Base module is paired with the thermostat.
Red Not
Paired
Base module is not paired with a
thermostat.
2 Red
Flashes then
Pause
Alarm
Base module indicating an alarm (Water
Leak, Smoke or CO2) accompanied by
descriptive text on the thermostat display.
Flashing
Red
Identify
Mode
Base module is in identify mode initiated by
the thermostat or web application.
Alternating
Green/Red
Factory
Reset
Hold the PAIR button for 10 seconds and
it begins to ash. Release and press again
briey to reset.
x y
Flashing
xtimes
Green then
ytimes Red
Firmware
Version
Indicates version x.y (eg. 2 green then 7
green = version 2.7.) Press and release PAIR
button within 10 seconds of power up.
nFlash Red
ntimes
Base
Module
Number
Indicates base module number (1-8). Press
and release PAIR button more than 10 sec-
onds after power up.
2

6
Parameter Description Key Action
Base Module Identify or Pair
base modules
Identify existing base module(s)
Pair additional base module(s)
Daylight Savings
Time (DST) Enable/Disable DST
or
Toggle Daylight Savings Time
Mode ON/OFF
Month Set Month Set Month – 1 to 12
Date Set Date Set Date – 1 to 31
Year Set Year Set Year
Hour Set Hour Set Hour – 12 am to 12 pm
Minute Set Minute Set Minute – 1 to 59
Emergency Heat Enable/Disable Toggle Emergency Heat “y” or “n”
Schedule Enable/Disable
Schedule Toggle Schedule “y” or “n”
To access Parameters, press & hold “Mode”
& “Fan” until a sound is played (3 seconds),
then release. Use the “Fan” button to scroll
forward and the “Mode” button to scroll
backward through the available parameters.
Parameter Setup

7
Access parameters
using the procedure
described earlier.
Press to
identify base mod-
ules. “All” ashes
indicating all mod-
ules. Press
to scroll through the
list of connected
base modules.
If any module has
been paired but has
lost its link to the
Thermostat, the pair-
ing status indicator
will blink along with
the number of the
module that has lost
its link.
Identify HTM-01 Base Module(s):

8
Press “FAN” to
select the module
desired.
The module ID
stops ashing, and
10-minute count-
down timer begins.
The LED on the module
corresponding to the ID
selected will begin ash-
ing red for 10 minutes.
If “All” is selected, the
LEDs on all connected
modules will ash red.
To exit ID mode, press &
hold the “Mode” and “Fan”
buttons until the chime
sounds. The display will
return to the home screen
and LEDs will stop ashing.

9
Press & hold “Mode”
& “Fan” until a sound
is played (3 seconds),
then release.
The display shows
the number of base
modules currently
paired.
Use the
button to begin a
10-minute count-
down to pair addi-
tional base modules.
Press the “PAIR” button
on each base module to
be added. The LED will
ash green until pairing
is complete.
Pairing Additional HTM-01 Base Module(s):

10
After pairing, the total number of base
modules will ash on the display. The
pairing sequence will time out after 10
minutes. To exit the parameters menu,
press & hold “Mode” and “Fan” until a
sound is emitted.
The Habitat HTE-01 Thermostat
will support a maximum of
eight HTM-01 Base Modules

11
Daylight Savings Time: Use
the button to toggle
DST Mode or . Press
“Fan” to continue.
:Use
buttons to set
the month. Press “Fan”
to continue.
: Use
buttons to set
the date. Press “Fan”
to continue.
: Use
buttons to set
the year. Press “Fan” to
continue.
: Use
buttons to set
hour. Press “Fan” to
continue.
: Use
buttons to set
the minute. Press “Fan”
to continue.
Daylight Savings Time, Date & Time Settings:

12
When prompted
to use
buttons to toggle
to “y”. Press “Fan”
to continue.
Press & hold “Mode”
& “Fan” until a sound
is played (3 seconds),
then release.
The display shows
the number of
base modules
currently paired.
Press “Mode” to
scroll back to the
Schedule Param-
eter and use the
button to
toggle schedule to
“Y”. Press “Fan”
to conrm.
Emergency Heat Setting:
Schedule Setup:
Use buttons
to enable (y) or disable (n)
Emergency Heat. If the
room temperature falls
below the Frost Protect
Setpoint (Administrative
Parameter), emergency
back-up heat will be
activated.

13
Use the buttons
to set the hour that the rst period
begins. Press “Fan” to continue.
Display Description Action when “Fan” pressed
Weekday (MF) or
Weekend (SS)
MF – Set periods*
SS – Set periods*
Same schedule
throughout the week Set periods*
Dierent schedule
each day
MO, TU, WE, TH, FR, SA, SU
– Set periods*
Use buttons to
set the minutes for the rst period.
Press “Fan” to continue.
• Choose Schedule Type
* Periods SS, WK, MO, TU, WE, TH, FR, SA, SU are set up in the same way as listed below MF.
• Period Setup

14
Use but-
tons to set the target set
point for Heating. Press
“Fan” to continue.
Set time and tempera-
ture set points for each
desired period.
To disable a period, press
the button until
is displayed.
Up to 6 periods per day
or group of days can be
programmed.
After the 6th period is
programmed, the HTE-01
Thermostat will move to
the next day or group,
depending on the sched-
ule type.
Once all periods and day
groups have been pro-
grammed, a prompt to
Update will be displayed.
Press “n” to accept the
current schedule or “y”
to make further changes.
Use buttons
to set the target set point
for Cooling. Press “Fan” to
advance to the next period.

15
HTE-01 Thermostat Administrative Parameters
To access Administrative Parameters, press & hold “Mode”
& “Fan” until the second beep is played (10 seconds) and
is displayed. Use the buttons to
change to . Use the “Fan” button to scroll forward
and the “Mode” button to scroll.
Parameter Display Description
Unpair
Modules
Use the
buttons to change from “n”
to “y”, then press “Fan”.
is
displayed.
Use the
buttons to select the
module(s) desired, then
press “Fan” to complete
the unpairing process.

16
Parameter Display Description
Enable Auto
Changeover
Use the buttons to toggle
between “n” (default) and “y”, then press “Fan”
to select. Selecting “y” enables the AUTO mode
selection using the “Mode” button.
Note: Disabling Auto Changeover by pressing
“n” will change schedule mode to the current
HEAT or COOL mode.
Button
Press Sound
Use the buttons to toggle
between “y” to “n”, then press “Fan”. Pressing
“n” will silence buttons. This does not aect
the feedback beeps for entering the Param-
eters/Administrative Parameters or Alarm
Output.
Enable
Compressor
O
Delay
Use the buttons to toggle
between “y” (default) and “n”, then press “Fan”
to select. Selecting “y” enables a delay timer
allowing the compressor to run after the de-
mand is satised.
Note: This parameter is not displayed if the
thermostat dip switch is set to “2 – FCU”.

17
Parameter Display Description
Compressor
O Delay
Time
Use the buttons to set
Compressor O Delay Time.
Range 3 to 5 minutes
Default 5 minutes
Increment 1 minute
Heat/Cool
Dierential
Use the buttons to change the
minimum dierential between the heat and
cool setpoints. Press “Fan” to accept.
If this value is changed, the current set point,
schedule set point, min/max setpoint or freeze
protection setpoint may be altered
automatically to accommodate the change.
Range 2°F to 6°F (1°C to 3°C)
Increment 1°F (0.5°C)
Span
(Hysteresis)
Use the buttons to set the span
between the room and set point temperatures.
Press “Fan” to accept and go to the next
parameter.
NOTE: The Span setting may be set no higher
than ½ the Heat/Cool Dierential.
Range 1°F to 3°F (0.5°C to 1.5°C)
Increment 1°F (0.5°C)
Other manuals for HTE-01
4
This manual suits for next models
1
Table of contents
Popular Controllers manuals by other brands

4qd
4qd PRO-160 Series instruction manual

Valco Instruments Co. Inc.
Valco Instruments Co. Inc. VICI EMHCA Installation & use

MDR
MDR MDR-2000 User's reference manual

Xiaomi
Xiaomi ZNCLDJ11LM user manual

Jebao
Jebao AQLink A1 quick start guide

National Instruments
National Instruments PXI-7340 User manual and specifications