Hague ST-200 User manual

Quality Water International
®
Smart Touch Controller
Setup Guide
Version 1.0

pg.2 Smart Touch Controller Setup Guide OR-05/18/15
Quality Water International
®
Table of Contents
Smart Touch Controller ............................................................................................................... 3
Setting The Touch Screen Controller............................................................................................... 3
Service Settings ........................................................................................................................... 4-7
Service Settings - History............................................................................................................. 6-7
Customer Settings........................................................................................................................... 8
Operating Modes ........................................................................................................................... 9

OR-05/18/15 Smart Touch Controller Setup Guide pg.3
Quality Water International
®
Smart Touch Controller
Setting the Touch Screen Controller
This appliance features a touch screen controller with a color screen display. The controller can be used to view the
appliance’s status, perform regenerations, and change settings. An independent Hague dealer should set the Service
Settings during the installation of the appliance.
Note: Ensure that the bottom
of the controller is firmly locked
onto the four tabs on the top of
the drive end cap assembly.
Figure 3: Smart Touch Controller
Customer Settings
Gallons Remaining
Message/Status Indicator
Regenerate
Service Settings
Water Flow Indicator
1. “OK” Button - Press after information is added and move to next screen.
2. “Back” Button - Navigates to the previous screen.
3. “Clr” Button - Resets all values to 0 and/or default value.
4. “Esc” Button - Escapes to the main menu.
5. “day” Button - Press each time to advance day when applicable.
6. “AP” Button - Toggles time between AM/PM when applicable.
Button Function
Incorrect
Correct

pg.4 Smart Touch Controller Setup Guide OR-05/18/15
Quality Water International
®
Smart Touch Controller
Service Settings
To program Service Settings on the controller, tap twice on the screen to bring up the “Main Menu”. Follow the following
steps to set the Smart Touch controller in the Service Settings.
Main Menu
Tap “Service Settings”
Units
Select units of measure
(Metric or English)
“OK” to continue
Password
Enter the password
“OK” to continue
History?
Option to show history
(Yes or No)
(see History in next section)
“OK” to continue
Language
Select the desired language
(English, Français, Español,
Deutsch, Italiano)
“OK” to continue
Total Regenerations
Displays number of regenerations
(For Reference Only)
Value does reset
“OK” to continue
Total Gallons
Displays number of gallons
that has passed through the unit.
(For Reference Only)
Value does reset
“OK” to continue
Note: The Service Settings must be set before the Customer Settings.
Mode (1-3)
Enter operating mode
(1 to 3)
(see Operating Modes section)
“OK” to continue
Hardness Grains
Enter Hardness test results
(1 to 199 Grains) or
(00000 to 3999 mg/L)
“OK” to continue

OR-05/18/15 Smart Touch Controller Setup Guide pg.5
Quality Water International
®
Smart Touch Controller
Iron ppm
Enter Iron test results
(0 to 99 ppm (mg/L))
“OK” to continue
Compensated
Hardness Grains
Automatically calculated
“OK” to continue
Brine/Rinse Minutes
Brine and rinse cycle duration
Preset - 030.0
(0 to 999.9)
“OK” to continue
Manganese ppm
Enter Manganese test results
(0 to 99 ppm (mg/L))
“OK” to continue
Capacity Grains
The desired capacity number
(52 to 9999 Grains) or
(788 to 6999 gm)
“OK” to continue
Backwash 2 Minutes
Second backwash cycle duration
Preset - 005.0
(0 to 999.9)
“OK” to continue
Salt
Select Regenerant
(Sodium or Potassium)
“OK” to continue
Backwash 1 Minutes
First backwash cycle duration
Preset - 001.0
(0 to 999.9)
“OK” to continue
Salt lbs.
Amount of salt for each regeneration.
Preset - 006.2
(1.0 to 80.0 lbs.)
(0.45 - 36.99 kg)
“OK” to continue
72-96hr Regeneration
Force regeneration setting
(Yes or No)
(see Operating Modes section)
“OK” to continue
Distiller/RO
Yes, if distiller or RO is in use
(Yes or No)
“OK” to continue
Turbine Test
Used for advanced diagnosis
(Yes or No)
“OK” to continue

pg.6 Smart Touch Controller Setup Guide OR-05/18/15
Quality Water International
®
Visible when
History = Yes
Visible when
History = Yes
Salt Monitor
Optional salt monitor in use
(Yes or No)
“OK” to continue
Dealer Name
Enter the dealership/business
phone number
“Ent” to continue
Regenerate Tonight
Set to regenerate tonight
(Yes or No)
“OK” to continue
Dealer Name
Enter the
dealership/business name
“Ent” to continue
Smart Touch Controller
H- Date
Enter Installation Date
Format - MMDDYY
(000000 to 999999)
“OK” to continue
H-Number of People
Enter number of
people in the household
(1 to 50)
“OK” to continue
H-Software. V.#
Software version number
(For Reference Only)
“OK” to continue
Service Settings - History
History - is an optional set of menus that acts as a clipboard for storing the history of water chemistry, total regenerations,
amount of water to pass through the unit, unit model number, and other settings. The history can be used for diagnosis
purposes or just for reference. History settings DO NOT affect operation.
When you select “Yes” in the history screen the following screens will be available. Take notice of the “H-” prefix to signify
that you are viewing the history.

OR-05/18/15 Smart Touch Controller Setup Guide pg.7
Quality Water International
®
Visible when
History = Yes
Visible when
History = Yes
Visible when
History = Yes
Visible when
History = Yes
Visible when
History = Yes
Visible when
History = Yes
Visible when
History = Yes
Smart Touch Controller
H-Hardness grains
Enter hardness test results
(1 to 199 ppm (mg/L))
“OK” to continue
H-Iron ppm
Enter Iron test results
(0 to 99 ppm (mg/L))
“OK” to continue
H-Sulfur ppm
Enter Sulfur test results
(0 to 99 ppm (mg/L))
“OK” to continue
H- Total Regenerations
Displays number of regenerations
Value does not reset
(For Reference Only)
“OK” to continue
H- Save History
Choose to save history
(Yes or No)
“OK” to continue
H-Manganese ppm
Enter Manganese test results
(0 to 99 ppm (mg/L))
“OK” to continue
H-pH ppm
Enter pH test results
(0 to 99.9)
“OK” to continue
H- Total Gallons
Number of gallons that
has passed through the unit.
Value does not reset
(For Reference Only)
“OK” to continue
H-Chlorine ppm
Enter Chlorine test results
(0 to 99 ppm (mg/L))
“OK” to continue
H-Iron Bacteria
Is Iron Bacteria present
(Yes or No)
“OK” to continue
H-Model Number
Enter Model Number
(00AAA to 99ZZZ)
“Ent” to continue

pg.8 Smart Touch Controller Setup Guide OR-05/18/15
Quality Water International
®
Visible when
Mode = 1
Set Time
Enter day, time, & AM/PM
Tap “day” to change day of the week
Tap “AP” for AM/PM.
(hh:mm)
“OK” to continue
Quiet Start Time
Enter silent mode.
Enter time & AM/PM
Tap “AP” for AM/PM.
(hh:mm)
“OK” to continue
Regeneration Time
Enter desired regeneration time
Enter time & AM/PM
Tap “AP” for AM/PM.
(hh:mm)
“OK” to continue
Quiet Stop Time
Stop silent mode.
Enter time & AM/PM
Tap “AP” for AM/PM.
(hh:mm)
“OK” to continue
Regeneration Time
Mode 1 & Days of Week Only
(see Operating Modes section)
“OK” to continue
# People
Enter number of
people in the household
(1 to 50)
“OK” to continue
Customer Settings
To program Customer Settings on the controller, tap twice on the screen to bring up the “Main Menu”. Follow the following
steps to set the Smart Touch controller in the Customer Settings.
Main Menu
Tap “Customer Settings”
Note: Whenever you experience an electrical outage, check your
controller for the correct time and date. Make any necessary corrections.
Note: The Service Settings must be set before the Customer Settings.
Smart Touch Controller

OR-05/18/15 Smart Touch Controller Setup Guide pg.9
Quality Water International
®
Mode 1 - Timer Mode - Frequency
Mode 1 - Timer Mode - Days of Week
Mode 2 - Demand Delayed Mode
Mode 3 - Demand Immediate Mode
72 - 96 Hour Regeneration
Smart Touch Operating Modes
When the appliance is in Mode 1 - Frequency, it will regenerate based on the frequency that is set.
For example every one day or up to every 20 days. The days between regenerations can be set in the “Service Settings”.
When Frequency is selected, the next
screen will allow you to chose how
many days between regenerations.
When Days of Week is selected, the
regeneration days can be selected in
the “Customer Settings”.
In “Customer Settings”, check the
days in which you would like the unit
to regenerate. “OK” to continue.
Enter the number of days (1-20)
between regenerations.
When the appliance is in Mode 1 - Days of Week, it will regenerate on a specific day(s) of the week.
When the appliance is in the Patented Savematic Demand Delayed mode, it will regenerate based on the actual water
usage and the total capacity of the appliance. The time that the regeneration takes place can be set, for example 2:00
AM. Should the total capacity be depleted before the set regeneration time, a forced regeneration will occur.
When the appliance is in the Demand Immediate mode, it will regenerate based on water usage alone. Regeneration will
occur when the capacity limit is reached. The time of regeneration cannot be set.
If this value is set to Yes, the appliance will be forced to regenerate every 96 hours unless a regeneration based on water
usage occurs within the time interval. The value should always be set to Yes if iron is present in the water.
The controller has a Timer mode (Mode 1 Frequency and Mode 1 Days of the Week), a Demand Delayed mode (Mode
2), and a Demand Immediate mode (Mode 3). These modes are equipped with Capacity Guard®, which ensures that a
supply of conditioned water will be available even with excessive water usage.
Operating Modes

pg.10 Smart Touch Controller Setup Guide OR-05/18/15
Quality Water International
®
Notes
Notes

OR-05/18/15 Smart Touch Controller Setup Guide pg.11
Quality Water International
®
Notes
Notes

Quality Water International
®
USA
Made In
Hague Quality Water International
4343 S Hamilton Road 614.836.2115
Groveport, OH 43125 www.haguewater.com
©2015 54115 Version 1.0 OR-05/18/15
Table of contents
Popular Controllers manuals by other brands

Jordan Valve
Jordan Valve LowFlow Mark 709 7M Installation & maintenance instructions

Mitsubishi Electric
Mitsubishi Electric MELSEC FX Series Structured programming manual

TKM
TKM MX170B Operation

Mikster
Mikster INDU WRC-2010H user manual

Zareba
Zareba AC POWERED user manual

aldes
aldes CONNECT BOX Assembly instructions