5
Flashlight on overhead guard
1.3 Setting in the configuration
menu
The Flashlight on overhead guard
option must be activated via the
configuration menu.
Requirements:
• Batteries inserted
• 4-digit code or diagnosis plug
97097737 present
If diagnosis plug is used:
Plug diagnosis plug into slot X20 of
controller A1 (Fig. 3/1).
Setting:
1. Turn on the machine.
2. Select the arrow soft key (Fig. 3/3)
on the control panel using the turn-
push knob (Fig. 3/2) and press to
access the sub-menu.
3. Select the configuration menu in the
sub-menu (Fig. 3/4).
Fig. 3
4. Enter the 4-digit code in the configu-
ration menu at the top (Fig. 3/5):
- Rotate the turn-push knob until the
required field is reached.
- Press the turn-push knob, then
rotate to set the value.
- Press again to save the value.
Alternatively, use the diagnosis plug!
5. In the configuration menu at the
bottom (Fig. 3/6), set the value of the
option and save by pressing the turn-
push knob. After confirming the last
digit, OK? appears. Press the turn-
push knob again to save the value.
Saved value is displayed in green.
If the value is not to be saved, exit
menu using the return key (Fig. 3/7).
Option Value
Flashlight on overhead
guard
1. A. 1.