Dear Customer,
thanks for choosing an Hamlet product. Please carefully follow
the instructions for its use and maintenance and, once this
product has run its life span, we kindly ask You to dispose of it
in an environmentally friendly way, by putting it in the separate
bins for electrical/electronic waste, or to bring it back to your
retailer who will collect it for free.
We inform You this product is manufactured with materials and components
in compliance with ROHS directives: 2002/95/CE, 2002/96/CE, 2003/108/CE;
with RAEE Directives: 2003/96/CE, Italian Legislative Decree 2005/151 and
below EEC Directives: 89/336 EEC, 92/31EEC, 93/68 EEC, EN 55022: 1998
Class B, EN 55024: 1998, EN 61000-4-2: 1998, EN 61000-4-3: 1996, EN
61000-4-4: 1995, EN 61000-4-5: 1995, EN 61000-4-6: 1996, EN 61000-4-8:
1993, EN 61000-4-11: 1994
IMPORTANT SAFETY INSTRUCTIONS
CAUTION To reduce the risk of electric shock, use only indoors and in
dry locations. Do not allow the device to be exposed to
moisture, rain, dust, excessive heat or direct sunlight. Do
not cover the Product.
CAUTION This socket outlet must be plugged directly into the power
source and must not be “daisy chained” together in serial
fashion with other power strips, UPS, other surge
protectors or extension cords.
CAUTION No all pole disconnection. Do NOT attach products which
are not for unattended use e. g. cloth iron, motors etc
USER MANUAL
This socket outlet Master Slave type with control electronic and surge filter is
designed for an automatic switch on and switch off of additional equipment's
e. g. Scanner, Printer, HiFi equipment's, etc.
In addition there is a surge protection of TV, HiFi, Video and PC and other
electronic equipment's against atmospheric influence and inductive and
capacitive peaks in the power supply line.
Function
Plug in to the Master socket outlet the leading main equipment. In a PC
system it would be e. g. the PC (min. power of the equipment 8-10W).
Connect to the Slave socket outlets your other equipment's as e. g. printer,
monitor, scanner or equiv. If you switch on your main equipment connected to
the Master socket outlet the slave equipment's will be automatically supplied
with mains voltage and switched on.

With the incorporated switch of the socket outlet you can disable this function.
If you operate the switch it is designed that the Slave socket outlets are
always connected to the mains Remark: If there is somehow a “failure” which
shows this characteristic check the switch.
Please pay attention that HiFi equipment's, video recorder or equiv. which are
feeded in the Slave socket outlet can loose the timer function. This is a
problem of the equipment and not a failure of our product.
Adjustment of the switching limit
On the long side of our product you will find a potentiometer. This you can
adjust in such away that the Slave socket outlets will be switched on and
switched off together with the Master socket outlet. Please pay attention that
here will be adjusted in the same time the lower switch limit. That means if
the Master equipment has a standby circuit which needs approx. 8-10W in
the standby mode (normally only older equipment's, newer are below 5W) it
can happen that the Slave socket outlets switch on and switch off in an
undefined manner. In this case please adjust the switching limit in a higher
value to give a correct operation of “On” and “Off”.
Please pay attention that the Master equipment has a stable power
consumption to prevent undefined switching on and off of the Slave socket
outlets.
Explanation of the product
Protected Indication that the internal surge protection is in function.
Power OK Indication that the Master socket outlet is supplied with
voltage.
Slave ON Indication that the Slave sockets outlets are feeded with
power.
The LED is illuminated as long as the Master equipment is
powered on resp. if the bridging switch gives a permanent
power to the Slave socket outlets.
Adjustment knob Potentiometer to adjust the switching limit for the Slave
sockets.
"Reset" This is an internal circuit breaker with 10 A. This will
operate if the socket outlet will be overloaded. In case of a
tripped circuit breaker disconnect the equipment's, unplug
the socket outlet and wait for approx. 1 min. and push the
circuit breaker back in. Please pay attention for the max.
load which is as following.

Features rear side: 2 slotted screw cross. Here you can fix the socket outlet
via 2 screws with a thread diameter of max. 4 mm. The screws have to be in
a distance of 130 mm.
FEATURES
Pmax Master: 575W (2,5A), 230V 50 Hz
Pmax Slave: 2300W (10A). 230V 50 Hz
Pmax total: 2300W (10A). 230V 50 Hz
Rated discharge Voltage ur 230V
Internal circuit breaker 10 Amp (resettable)
Rated Current: 10Amps
Rated Voltage: 250 VAC, 50Hz
Clamping Voltage: 775V
Max. Energy:
–Full 3-Line Surge protection H-N, H-G, N-G: 714 Joules
Max. Current: Full Type: 19500A
Max Spike Voltage: 6KV
Response Time: < 1 Nanosecond
EMI/RFI Noise Filter
–Frequency Range: 150KHz ~ 100MHz
–Attenuation: Up to 40 dB
Tel/Fax/Modem Protection
–Jack Type: RJ11
–Energy: 320 Joules
6 AC Outlets with Children Safety Shutters
5 Slave Outlets + 1 Master Outlet
RESET button
Voltage regulator 8W-70W
Heavy Duty Power Cord
Unlighted Rocker Switch
Surge Protected Indicator
Power OK Indicator
Slave ON Indicator
This product has no repairable components. Should the internal fuse (not
replaceable) for the Master socket outlet (max. load 575W [2,5A]) operate the
socket outlet has to be replaced. In the same case if the power supply is
defective it is necessary to throw away the socket outlet.
This product has a child protection but never the less please check that
child's do not play with socket outlets. Protect your children and prevent that
they try to push into the socket outlets screw drivers or any other subject.