Microwave motion sensor with corridor function (SKYLUX-MS)
Note: Sensor and remote control available separately as accessories. The sensor can only be congured via a remote controller.
Default sensor setting without remote controller Scan for Install Guide
SKYLUX/ Sensor & Remote
HANECO LED HIGHBAY INSTALLATION GUIDE
For more information
www.haneco.com.au
1300 001 LED (533)
Microwave sensor specications
Brightnes 100% Daylight sensor Disabled
Sensitivity 100% Stand-by Dim 30%
Hold Time 5min Stand-by period 60min
Microwave Frequency 5.8 GHz
Transmitting Power <1mW
Mounting Height 12m Max.
Detection Radius 4m
Detection Speed 0.5~1.5m/s
Microwave motion sensor
1. Remove cover by rotating anticlockwise. 2. Install the motion sensor by aligning the groove and rotate
clockwise to lock.
Microwave motion sensor installation
3. Complete custom setting using a remote controller.
For more information
www.haneco.com.au
1300 001 LED (533)
ART09122019
Remote Controller Specications (SKYLUX-REMOTE)
KEY FUNCTION KEY FUNCTION
Press for permanent ON/OFF.
Sensor function will be disabled, press
“AUTO” to resume normal sensor
operations.
Press to resume normal sensor
operations with previous
congurations.
Display current congurations.
Press to enter test mode for sensor
sensitivity (Hold time for 2s).
Stand-by period and daylight sensing
are disabled.
Press “AUTO” to resume normal
sensor operations.
Upload selected congurations to the
sensor.
Increase/Decrease setting conditions.
Navigate UP/DOWN.
Default: Disabled.
Daylight sensor set point.
When the ambient light level drops
below or exceeds the pre-set lux level,
the sensor will wait and monitor the
changes for 1 min before switching the
luminaire ON or OFF.
Navigate LEFT/RIGHT.
Conrm and save pre-set parameters.
Press for factory reset.
Default:
Pre-set congurations can be updated
and saved within the four modes.
Power Supply 2 x AAA 1.5V Battery
Communication 940 nm Infrared Tx & Rx
Upload Range Up to 15m (50ft.)
Dimensions 123 x 70 x 20 mm
Brightness 100% Daylight sensor Disabled
Sensitivity 100% Stand-by dim 30%
Hold time 5 min Stand-by period 60 min
For more information
www.haneco.com.au
1300 001 LED (533)
ART05062019
1. Press “AUTO”.
2. Press “DISP” to show latest congurations.
3. Press or to enter settings. Navigate to the desired setting by to select new parameters.
4. Press “OK” to conrm all parameters and save.
5. Aim at the luminaire and press “SEND” to upload new parameters. The luminaire will icker ON and OFF once as conrmation.
1. Press “MODE 1, 2, 3 or 4”. The remote will display existing congurations.
2. Press to select new parameters.
3. Press “OK” to conrm all parameters and save.
Sensor conguration
Congure new MODE
Default MODE
BRIGHTNESS SENSITIVITY HOLD TIME DAYLIGHT SENSOR STAND-BY DIM STAND-BY PERIOD
MODE 1 100% 75% 5 min Disabled 30% 30 min
MODE 2 70% 75% 1 min Disabled 30% +∞ (Permeant ON)
MODE 3 70% 75% 5 min 30LUX 30% 30 min
MODE 4 70% 75% 1 min (30LUX/300LUX) 30% +∞ (Permeant ON)
BRIGHTNESS
Default: 100%
Adjust the brightness during hold time:
70%, 80%, 90%, 100%
DAYLIGHT SENSOR
Default: Disabled
Lux level setting:
Select 10lux, 20lux, 50lux, 100lux,
300lux, 500lux
Use current lux level as threshold:
Select
Disable:
Select to disable daylight sensor.
SENSITIVITY
Default: 100%
Adjust sensor sensitivity:
20%, 50%, 75%, 100%
HOLD TIME
Default: 5 min
The period the luminaire remains ON
when no presence is detected.
10s, 1min, 5min, 10min, 15min, 20min,
30min, 60min
STAND-BY DIM
Default: 30%
Adjust the stand-by dimming level:
0% (ON/OFF control), 10%, 30%, 50%
STAND-BY PERIOD
Default: 60 min
Select stand-by period:
+∞ (Permeant ON), 1min, 30min, 60min
• Installation must be carried out by a licenced electrician and in accordance
with these instructions and relevant Australian standards and local regulations.
• Ensure input voltage conforms within product specications.
• Ensure wires are securely connected.
• Before switching on, ensure all wires are correctly connected.
• The warranty is void if product is not installed according to the instructions.
Note: Product technical information and specication may change over time
without prior notice. For latest information, please contact our customer service
or visit our website www.haneco.com.au
WARNING
Product Code: SKYLUX-MS
SKYLUX-REMOTE
For more information
www.haneco.com.au
1300 001 LED (533)
ART05062019
Corridor Function

This manual suits for next models

1

Other Haneco Security Sensor manuals

Haneco HIGHBAY-MS User manual

Haneco

Haneco HIGHBAY-MS User manual

Haneco PROXIMA-TRI User manual

Haneco

Haneco PROXIMA-TRI User manual

Popular Security Sensor manuals by other brands

THORLABS PDAPC2 user guide

THORLABS

THORLABS PDAPC2 user guide

Trinity MPS 350 Product Description and Assembly Manual

Trinity

Trinity MPS 350 Product Description and Assembly Manual

Leakomatic Pro 1 installation manual

Leakomatic

Leakomatic Pro 1 installation manual

SensoScientific Sub-1 GHz Series Quick setup guide

SensoScientific

SensoScientific Sub-1 GHz Series Quick setup guide

VIDICON BINGO installation instructions

VIDICON

VIDICON BINGO installation instructions

Kanlux ALER MINI quick start guide

Kanlux

Kanlux ALER MINI quick start guide

AVE AF969R manual

AVE

AVE AF969R manual

York 2SD04700124 installation instructions

York

York 2SD04700124 installation instructions

Agara P1 user manual

Agara

Agara P1 user manual

Argus Security L-MC-SG/865 manual

Argus Security

Argus Security L-MC-SG/865 manual

Siemens DB-HR installation instructions

Siemens

Siemens DB-HR installation instructions

GoveeLife H5043 user manual

GoveeLife

GoveeLife H5043 user manual

STEINEL HS 2160 manual

STEINEL

STEINEL HS 2160 manual

Brookstone BKSSDW user manual

Brookstone

Brookstone BKSSDW user manual

STEINEL IS 130-2 manual

STEINEL

STEINEL IS 130-2 manual

Joy-it JT-RAD01 manual

Joy-it

Joy-it JT-RAD01 manual

Pilz PSEN opII mirror column Series operating manual

Pilz

Pilz PSEN opII mirror column Series operating manual

Honeywell SS2-A Installation guide and operating manual

Honeywell

Honeywell SS2-A Installation guide and operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.