HI726
Nickel High Range
INSTRUCTION MANUAL
Before using Hanna Instruments products, make sure that they are entirely suitable for
your specific application and for the environment in which they are used. Operation of
these instruments may cause unacceptable interferences to other electronic equipment, thus
requiring the operator to take all necessary steps to correct such interferences. Any variation
introduced by the user to the supplied equipment may degrade the instrument’s EMC
performance. To avoid damages or burns, do not put the instrument in microwave oven. For
yours and the instrument safety do not use or store the instrument in hazardous environments.
Recommendations for Users
Accessories
Reagent Sets
HI726-25 Reagents for 25 Nickel High Range tests
Other Accessories
HI726-11 Nickel HR Certified Standard Kit
HI731225 Cuvette Black Cap for Checker®HC Colorimeters (4 pcs.)
HI731318 Cloth for wiping cuvettes (4 pcs.)
HI731321 Glass cuvettes and Seal Cap for Checker®HC Colorimeters (4 pcs.)
HI731353 Cuvette Seal Cap for Checker®HC Colorimeters (4 pcs.)
HI740028P 1.5V AAA batteries (12 pcs.)
HI93703-50 Cuvette cleaning solution (230 mL)
IST726 05/18
HI726 is warranted for a period of one year after date of purchase against defects in
workmanship and materials when used for their intended purpose and maintained according
to instructions. This warranty is limited to repair or replacement free of charge. Damage due
to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If service
is required, contact your local Hanna Instruments Office. If under warranty, report the model
number, date of purchase, serial number and the nature of the problem. If the repair is not
covered by the warranty, you will be notified of the charges incurred. If the instrument is to
be returned to Hanna Instruments, first obtain a Return Goods Authorization number from the
Technical Service department and then send it with shipping costs prepaid. When shipping any
instrument, make sure it is properly packed for complete protection.
Warranty
• It is important that the sample does not contain any debris.
• Whenever the cuvette is placed into the measurement cell, it
must be dry outside, and completely free of fingerprints, oil and
dirt. Wipe it thoroughly with HI731318 or a lint-free cloth prior
to insertion.
• Shaking the cuvette can generate bubbles, causing higher
readings. To obtain accurate measurements, remove such bubbles
by swirling or by gently tapping the cuvette.
• Do not let the reacted sample stand for too long after reagent
is added, as accuracy will be affected.
• After the reading it is important to immediately discard the
sample, otherwise the glass might become permanently stained.
Tips for an Accurate Measurement
To save the battery, the instrument shuts down after 10 minutes of non-use and 2 minutes
after reading.
One fresh battery lasts for a minimum of 5000 measurements. When the battery is dead the
instrument will display “bAd” then ”bAt” for 1 second and then turns off.
To restart the instrument, the battery must be replaced with a new one.
To replace the instrument’s battery:
• Turn the instrument off by holding the button until the meter shuts off.
• Turn the instrument upside down and remove the battery cover with a screwdriver.
• Remove the battery from its location and replace it with a new one, inserting the negative
end first.
• Insert the battery cover and replace the screw with a screwdriver.
Battery Management
• Turn the meter on by pressing the button. All
segments will be displayed. When the display
shows “Add”, “C.1” with “Press” blinking, the
meter is ready.
• Fill the cuvette with 10 mL of unreacted sample
and replace the cap. Place the cuvette into the
meter and close the meter’s cap.
• Press the button. When the display shows
“Add”, “C.2” with “Press” blinking the meter
is zeroed.
• Remove the cuvette from the meter and unscrew
the cap. Add the content of one packet of
HI726-0 reagent. Replace the cap and shake
gently until the reagent is completely dissolved.
Place the cuvette back into the meter.
• Press and hold the button until the timer is
displayed on the LCD (the display will show
the countdown prior to the measurement) or,
alternatively, wait for 1 minute and press the
button.
• The instrument displays concentration in g/L of
nickel. The meter automatically turns off after
2 minutes.
INTERFERENCE
Interference may be caused by copper.
Light High: There is too much light to perform a measurement. Please
check the preparation of the zero cuvette.
Light Low: There is not enough light to perform a measurement. Please
check the preparation of the zero cuvette.
Inverted Cuvettes: The sample and the zero cuvette are inverted.
Under Range: A blinking “0.00” indicates that the sample absorbs less
light than the zero reference. Check the procedure and make sure you use
the same cuvette for reference (zero) and measurement.
Over Range: A flashing value of the maximum concentration indicates
the reading is over range. Dilute the sample and re-run the test.
Battery Low: The battery must be replaced soon.
Dead Battery: This indicates that the battery is dead and must
be replaced. Once this indication is displayed, normal operation of
the instrument will be interrupted. Change the battery and restart
the meter.
Thank You
Thank you for choosing a Hanna Instruments product. Please read this instruction
manual carefully before using the instrument.
For more information about Hanna Instruments and our products, visit
www.hannainst.com.
For technical support, contact your local Hanna Instruments Office or e-mail us at
[email protected].
Find your local Hanna Instruments Office on www.hannainst.com.
Please examine this product carefully. Make sure that the instrument is not damaged. If
any damage occurred during shipment, please contact your local Hanna Instruments Office.
Each HI726 meter is supplied complete with:
• Sample Cuvettes and Caps (2 pcs.)
• Reagent for 6 tests
• 1.5V AAA Battery (1 pc.)
• Instruction Manual and Quick Reference Guide
Preliminary Examination
Range 0.00 to 7.00 g/L (ppt)
Resolution 0.01 g/L
Accuracy ±0.10 g/L ±5% of reading @25 °C/77 °F
Light Source Light Emitting Diode @575 nm
Light Detector Silicon Photocell
Method Adaptation of the photometric method. The reaction between nickel
and the reagent causes a blue tint in the sample.
Environment 0 to 50 °C (32 to 122 °F); max 95% RH non-condesing
Battery Type 1.5V AAA (1 pc.)
Auto-Shut off After 10 minutes of non-use and 2 minutes after reading
Dimensions 86.0 x 61.0 x 37.5 mm (3.4 x 2.4 x 1.5”)
Weight 52 g (1.84 oz.)
Specifications
Cover
Cuvette with cap
Cuvette holder
LCD Liquid Crystal Display
Operation Button
Functional Description
Errors and Warnings
Measurement Procedure
Hanna Instruments reserves the right to modify the design, construction or appearance of
its products without advance notice.

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HI97726 User manual

Hanna Instruments

Hanna Instruments HI97726 User manual

Hanna Instruments edge PHM4092 User manual

Hanna Instruments

Hanna Instruments edge PHM4092 User manual

Hanna Instruments HI 6052 User manual

Hanna Instruments

Hanna Instruments HI 6052 User manual

Hanna Instruments Combo Grochek HI 991404 User manual

Hanna Instruments

Hanna Instruments Combo Grochek HI 991404 User manual

Hanna Instruments HI5321 User manual

Hanna Instruments

Hanna Instruments HI5321 User manual

Hanna Instruments HI97105 User manual

Hanna Instruments

Hanna Instruments HI97105 User manual

Hanna Instruments HI9812-51 User manual

Hanna Instruments

Hanna Instruments HI9812-51 User manual

Hanna Instruments HALO 2 HI9810392 User manual

Hanna Instruments

Hanna Instruments HALO 2 HI9810392 User manual

Hanna Instruments pH 300 User manual

Hanna Instruments

Hanna Instruments pH 300 User manual

Hanna Instruments HI 8424 User manual

Hanna Instruments

Hanna Instruments HI 8424 User manual

Hanna Instruments HI 88713 User manual

Hanna Instruments

Hanna Instruments HI 88713 User manual

Hanna Instruments pHep HI 98107 User manual

Hanna Instruments

Hanna Instruments pHep HI 98107 User manual

Hanna Instruments HI97711 User manual

Hanna Instruments

Hanna Instruments HI97711 User manual

Hanna Instruments HI 96811 User manual

Hanna Instruments

Hanna Instruments HI 96811 User manual

Hanna Instruments HI 9813-5 User manual

Hanna Instruments

Hanna Instruments HI 9813-5 User manual

Hanna Instruments HI 93732N User manual

Hanna Instruments

Hanna Instruments HI 93732N User manual

Hanna Instruments HI 4101 User manual

Hanna Instruments

Hanna Instruments HI 4101 User manual

Hanna Instruments HI 38020 User manual

Hanna Instruments

Hanna Instruments HI 38020 User manual

Hanna Instruments HI99151 User manual

Hanna Instruments

Hanna Instruments HI99151 User manual

Hanna Instruments Checker HI 711 User manual

Hanna Instruments

Hanna Instruments Checker HI 711 User manual

Hanna Instruments HI99111 User manual

Hanna Instruments

Hanna Instruments HI99111 User manual

Hanna Instruments HI 142 Series User manual

Hanna Instruments

Hanna Instruments HI 142 Series User manual

Hanna Instruments HI98165 User manual

Hanna Instruments

Hanna Instruments HI98165 User manual

Hanna Instruments HI 99301 User manual

Hanna Instruments

Hanna Instruments HI 99301 User manual

Popular Measuring Instrument manuals by other brands

IKA IKA C 48 operating instructions

IKA

IKA IKA C 48 operating instructions

Rohde & Schwarz R&S NGU Series Getting started

Rohde & Schwarz

Rohde & Schwarz R&S NGU Series Getting started

SoftdB Mezzo Sound Intensity Probe user guide

SoftdB

SoftdB Mezzo Sound Intensity Probe user guide

Rish Eine+ operating manual

Rish

Rish Eine+ operating manual

Eaton Moeller Series manual

Eaton

Eaton Moeller Series manual

TLV EF200F-C technical information

TLV

TLV EF200F-C technical information

CETAC M7500 Guide

CETAC

CETAC M7500 Guide

OPTOKON PM-212 instruction manual

OPTOKON

OPTOKON PM-212 instruction manual

Teledyne Lecroy RP4030 Operator's manual

Teledyne Lecroy

Teledyne Lecroy RP4030 Operator's manual

Sekonic SPECTROMASTER C-7000 operating manual

Sekonic

Sekonic SPECTROMASTER C-7000 operating manual

TEC DG-1000 manual

TEC

TEC DG-1000 manual

Luna 4600 user guide

Luna

Luna 4600 user guide

Fluke 789 user manual

Fluke

Fluke 789 user manual

Shimpo DT-725 instruction manual

Shimpo

Shimpo DT-725 instruction manual

Hach IntelliCAL ISENH3181 Series user manual

Hach

Hach IntelliCAL ISENH3181 Series user manual

ELA Active RFid quick start

ELA

ELA Active RFid quick start

TL Electronic TL-3524 user manual

TL Electronic

TL Electronic TL-3524 user manual

Pacetronix ZEUS-1 manual

Pacetronix

Pacetronix ZEUS-1 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.