Turn Checktemp®1 ON: all LCD segments are displayed for 1 second. CalCheck®
A message of “CAL“ and “-0-
can now start using Checktemp®1. If CalCheck® displays the “Err” message while
measuring temperature, remember that:
·The temperature sensor is located at the tip of the stainless steel probe.
·It is necessary to wait for a few seconds for the display to stabilize.
Meter Setup
time. To enter the Setup MODE, press the SET button located inside the battery
To enter the Setup mode, remove battery cover and press SET button. The display
will show the current temperature unit (E.g. “°C“). Then:
·Use the ON/OFF button to switch between “ºC” or “ºF”. Press SET once to save.
·Use the ON/OFF button to cycle through the following Auto Shut O options:
8 minutes (“d08”, default value), 60 minutes (“d60”), OFF (“d--”). Press the SET
button once to save.
Range -50.0 to 150.0 ºC / -58.0 to 302 ºF
Resolution 0.1 ºC (-50.0 to 150.0 ºC)
0.1 ºF (-58.0 to 199.9 ºF) / 1 ºF (above 200 ºF)
Accuracy
±0.2 ºC (-30.0 to 120.0 ºC)
±0.3 ºC (outside: -50.0 to -30.0 ºC and 120.0 to 150.0 ºC)
±0.5 ºF (-22.0 to 199.9 ºF)
±1 ºF (outside: -58.0 to -22.0 ºF and 200 to 302 ºF)
Probe stainless steel, 1 m (3.3') cable
Environment -30 to 50 ºC (-22 to 122 ºF)
Battery Type 3 x 1.5 V AAA alkaline
Battery Life approx. 2 years
Auto O 8 min (default), 60 min or OFF
Dimensions 107 x 59 x 17 mm (4.2 x 5.3 x 0.7")
Weight 130 g (4.6 oz.)
Certication EN 13485:2001 - Suitability: Storage; Environment: E; Accuracy Class: 0.5;
Protection: IP65
Battery Replacement
Replace the battery when the battery symbol is blinking or when Checktemp ®1
does not turn on. Open the compartment and replace the three AAA batteries, while
paying attention to their polarity. Close battery cover.
Note: Batteries should only be replaced in a safe area using the battery type specied in this instruction manual.
Old batteries should be disposed in accordance with local regulations.
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent
of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895, USA.
IST98509
09/14
Warranty
Checktemp®1 is guaranteed for a period of one year after date of purchase against defects in workmanship and materials
when used for their intended purpose and maintained according to instructions. This warranty is limited to repair or
replacement free of charge. Damage due to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If
service is required, contact your local Hanna Oce. If under warranty, report the model number, date of purchase, serial number
and the nature of the problem. If the repair is not covered by the warranty, you will be notied of the charges incurred. If the
instrument is to be returned to Hanna Instruments, rst obtain a Returned Goods Authorization number from the Technical
Service department and then send it with shipping costs prepaid. When shipping any instrument, make sure it is properly
packed for complete protection.
Recommendations for Users
Before using Hanna Products, make sure that they are entirely suitable for your specic application and for the environment in
which they are used.Operation of these instruments may cause unacceptable interferences to other electronic equipment, thus
requiring the operator to take all necessary steps to correct such interferences. Batteries should only be replaced in a safe area
using the battery type specied in this instruction manual. Any variation introduced by the user to the supplied equipment may
degrade the instrument’s EMC performance. To avoid damages or burns, do not put the instrument in microwave oven. For yours
and the instrument safety do not use or store the instrument in hazardous environments.
Silicone Probe Cable
Liquid Crystal Display
Maximum Immersion Level
Temperature Probe
ON/OFF
Button
SET
Button
4 cm
1.5” Recommended
Immersion Level
Battery
Cover
REAR
EN 13485
Use Storage
Environment E
Accuracy 0.5
EN 13485
Use Storage
Environment E
Accuracy 0.5